maintenance guide
By-Pass Assembly
Tools | Time | 5 min |
1
Drain boiler (see 3.3). Remove the second clip and pull the assembly toward you
Push on the
Temperature Sensor
Tools | Time | 5 min |
NTC1 NTC2
1
| NTC1 : Black wires | Unplug the electrical connectors | Remove the clip and the temperature sensor | |
| NTC2 : Grey wires |
|
|
|
|
|
|
|
|
| TEMPERATURE (°C) |
|
| RESISTANCE (kOmh) |
|
|
|
|
|
| 0 |
|
| 27 |
| 10 |
|
| 17 |
| 20 |
|
| 12 |
| 25 |
|
| 10 |
| 30 |
|
| 8 |
| 40 |
|
| 5 |
| 50 |
|
| 4 |
| 60 |
|
| 3 |
| 70 |
|
| 2 |
| 80 |
|
| 1,5 |
44