maintenance guide
Fault finding
Overheat |
|
|
|
Insufficient | Water pressure |
circulation |
|
|
|
| Bleed heat exchanger |
|
|
| Pump operation |
|
|
| CH return filter for blockages |
|
|
| Circulation around boiler (blockages) |
|
|
| ntc temperature sensors |
|
|
|
|
Insufficient water | Water pressure gauge for correct pressure |
(request filling) |
|
|
|
| Check for waterleaks on the entire system |
|
|
|
|
CH Flow temp. | Check connections and wiring to temp |
probe circuit open/ | sensors |
short circuit |
|
|
|
CH Flow temp. | Resistance values of temp sensors |
probe circuit open/ |
|
short circuit |
|
|
|
Heating delivery | Details in maintenance guide in installation |
probe problem | manual |
|
|
|
|
Floor thermostat | Check terminals TA2 for presence of link |
contact open | wire |
|
|
|
|
EEPROM Error | Check the EEPROM connection onto the |
| pcb |
|
|
Communication | Check connection and wiring onto all |
error | devices, main and display pcb |
|
|
Main PCB error |
|
|
|
|
|
Too many (>5) | Identify reason for lockout from table and |
resets in 5 minutes | check for relevant faults |
|
|
|
|
No Flame detected | Insufficient working gas pressure |
|
|
1st Ignition failed | Spark electrode/wiring connectors |
|
|
2nd Ignition failed | Ignition electrode/wiring connectors |
|
|
Flame | Spark generator/wiring connectors |
|
|
| Check flue system for correct assembly/ |
| termination |
|
|
| Check earth |
|
|
| Gas valve |
|
|
| CO2 settings |
|
|
| Soft light rate |
|
|
Flame detected | Ignition electrode/wiring connectors |
with gas valve |
|
closed |
|
|
|
| Ignition electrode wiring connection onto |
| main pcb |
|
|
|
|
Flame lift | Insufficient working gas pressure |
|
|
| Check flue system for correct assembly/ |
| termination |
|
|
| CO2 settings |
|
|
|
|
Thermofuse open | Check wiring and connections to |
| thermofuse |
|
|
| Check integriry of main heat exchanger |
|
|
|
|
Fan speed error | Check fan |
|
|
| Check wiring connections from fan to pcb |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
52