Gas-Fired Products 150, N7/L7, 100, 40, 175, 200 manual Body Components, Description

Page 53

BODY COMPONENTS

ITEM

PART NO.￿

DESCRIPTION

1

02266010

Reflector Speed Clip

2

43980010

Wire Hanger

3

42873000

“U” Bolt Clamp, 4” OD Tube

3a

02127110

5/16-18 Hex Nut (2 per “U” Bolt)

4

43318000

Tube Support/Hanger Bracket, 13”

5

43319050

Reflector, 4’-11½” long (5’ section only; 1 per 5 ft. body section)

6

43319100

Reflector, 9’-11½” long (10’ section only; 1 per 10 ft. body section)

7

43320000

End Reflector (optional)

8

43342000

Corner Reflector Package (optional)

9

42921000

Tube Flange Gasket

10*

44028170

10’ Tube Assembly Kit, 4” OD, ATC steel with one 6-hole flange (start tube)

10a**

44028030

10’ Tube Assembly Kit, 4” OD, ALC steel with one 24-hole flange (start tube)

11

44028100

10’ Tube Assembly Kit, 4” OD, HRS steel without flanges (extension tube & exhaust tube)

11a

44028060

10’ Tube Assembly Kit, 4” OD, ALC steel without flanges (extension tube & exhaust tube)

12

44028120

5’ Tube Assembly Kit, 4” OD, HRS steel without flanges (extension tube & exhaust tube)

12a

44028010

5’ Tube Assembly Kit, 4” OD, ALC steel without flanges (extension tube & exhaust tube)

13

43208010

4” O.D. Elbow Package

14

02189020

#10 x ½” Self-Drilling Screw

15

30462980

4” OD Tube Compression Coupling w/bolts

16

43208020

4” OD U-Bend(Required for PTU Only)

17

43488000

U-Bend Reflector (PTU Option)

18

30504500

Flue Adapter Collar

19

44152240

Turbulator (see specifications section 5.0 for quantities)

*Required on 40ft, 50ft, 60ft and 70ft systems for mounting of control box.

**Required on 10ft, 20ft and 30ft systems for mounting of control box.

17

 

 

 

8

 

 

 

 

1

 

 

 

 

16

 

 

 

 

 

 

 

 

 

5

 

6

 

 

3

 

 

 

13

 

 

 

 

 

 

 

 

 

14,15

14,15

4

1

 

 

 

 

 

2

 

3a

7

 

 

 

 

12,12a

 

 

 

 

5 FT

 

 

 

10,10a,11,11a

 

BODY COMPONENTS

2

 

 

 

 

 

 

 

 

 

 

19

7

3

 

 

 

14,18

1

 

 

 

 

410 FT

BODY COMPONENTS

93a

ALL ILLUSTRATIONS ARE INTENDED TO GIVE THE GENERAL IMPRESSION OF UNITS ONLY. OTHER COMBINATIONS OF 5 FT. AND 10 FT. SECTIONS, AND ONES WITH OR WITHOUT THE ELBOW PACKAGE ARE POSSIBLE. PLEASE CONSULT WITH YOUR Space-Ray SALES REPRESENTATIVE. WE RESERVE THE RIGHT TO ALTER ANY SPECIFICATION WITHOUT NOTICE.

 

Form #43343530

–52–

JJuly 08

Image 53
Contents Installation and Operation Instructions Table of Contents Installer Responsibility SafetyInstallation Requirements General InformationHigh Altitude For Canada onlyMinimum Clearances to Combustibles Minimum Clearances to CombustiblesPacking List SpecificationsNatural GAS Burner Package NumbersPTU 40-200 Body Package Descriptions Reflector, 4’ 11 ½’ End Reflector Accessory Package AccessoriesExhaust Hood Package Emitter Length Body Length Model Typical Layouts PTU / PTS SeriesPoisonous GAS and Soot Hazard Typical Assembly LayoutPTS Series Dimensions PTU Series Joining of Tube Sections Heater AssemblyTypical Assembly Overview PTU 40FT Shown Suspension Hazard Typical Suspension MethodsCUT Hazard Assembly of Tube SectionsMIN 8’ MAX 10’ Between Hangers Assembly of Extension SectionInserting Turbulators Ft. Turbulator Sections Adding ReflectorsAdding Optional Corner Reflector PTS only Adding Optional 90º Elbow PTS onlyAdding Optional U-BEND Reflector PTU only Adding 180U-Bend PTU onlyAttaching Burner BOX Assembly Instructions Connecting the Tiss SystemEnd View Angle Mounted Heaters only Do not USE AN Open Flame of ANY Kind to Test for Leaks GAS Connections and RegulationsKEY Dimensions and Components of the GAS Connections Manifold PRESSURE- Combination GAS Valve is Factory SET Instructions for Pressure Test Gauge ConnectionSupply Pressure GAS Control Valve Electrical ConnectionsTH/W Ignition Module Terminal Designations 24VAC/RPS/W GNDLOW Voltage 24V Thermostat Connections Multiple Heaters LOW Voltage 24V Thermostat Connections Single HeaterSingle Heater Venting Vertical Through the Roof VentingSingle Heater Venting Horizontal Through Sidewall #10 Self-Drill Vent Pipe Screws Indirect Venting Unvented Heaters Common Vent DiameterDirect Outside AIR for Combustion AIR for CombustionSide View Lighting and Shutdown InstructionsSequence of Operation Burner Component Locations Electric Shock & Explosion Hazard Cleaning and Maintenance22.0 Troubleshooting GuideForm #43343530 JJuly Replace air switch Restart Troubleshooting Yes Removal of Main Burner and Electrodes Replacing PartsAIR Switch Pressure Check Removal of GAS Valve and Manifold AssemblyTo Check Flame Sensor Circuit Ignition Module DiagnosticsIgnition System Checks Replacement Parts Guide Burner BOX Installation DataLabels/Manual 22c Description Body Components