Gas-Fired Products N7/L7, 100, 40, 150, 175, 200 manual Reflector, 4’ 11 ½’

Page 9

Body Fastener Kit (included in body packages)

42907190

42907210

42907210

42907221

42873000

U-Bolt

2

4

4

6

02127110

Hex Nut, 5/16-18

5

8

8

13

02189020

HWHSM Screw, #10-16 x ½” TEKS

8

14

14

24

 

 

 

 

 

 

 

U-Bend Package

43208020

43208020

43208020

43208020

42873000

U-Bend

1

1

1

1

43318500

31” Tube Support/Hanger Bracket

1

1

1

1

30462980

Tube Coupling

1

1

1

1

02189020

HWHSM Screw, #10-16 x ½” TEKS

2

2

2

2

 

 

 

60Ft. System

 

 

 

 

40 Ft. Pkg.

 

20 Ft. Pkg.

PTU Body Packages – Alumi-Therm/Hot Rolled

44137100

 

44135010

Part #

 

Each Body Package Includes:

Qty.

 

Qty.

42912169

 

10 Ft. Tube with 6 Hole Flange (Alumi-Therm)

1

 

-

41932101

 

10 Ft. Tube less Flanges (Hot Rolled)

3

 

2

41932051

 

5 Ft. Tube less Flanges (Hot Rolled)

-

 

-

43319100

 

Reflector, 9’ 11½”

4

 

2

43319050

 

Reflector, 4’ 11 ½’

-

 

-

30462980

 

Tube Coupling

3

 

2

43318000

 

Tube Hanger/Support Bracket, 13”

4

 

2

43980010

 

Wire Hanger

4

 

2

 

 

 

 

 

Body Fastener Kit (included in body packages)

42907210

 

42907219

42873000

U-Bolt

4

 

2

02127110

Hex Nut, 5/16-18

8

 

5

02189020

HWHSM Screw, #10-16 x ½” TEKS

14

 

8

 

 

 

 

 

 

 

 

U-Bend Package

43208020

 

 

42873000

U-Bend

1

 

 

43318500

31” Tube Support/Hanger Bracket

1

 

 

30462980

Tube Coupling

1

 

 

02189020

HWHSM Screw, #10-16 x ½” TEKS

2

 

 

70Ft. System

 

40 Ft. Pkg.

30 Ft. Pkg.

44137120

44136040

 

Qty.

Qty.

1

-

2

3

2

-

3

3

2

-

4

3

5

3

5

3

 

 

 

 

42907220

42907200

 

5

3

 

10

6

 

18

10

 

 

 

 

43208020

 

 

1

 

 

1

 

 

1

 

 

2

 

E) PTU 40-200 Series Body Package Descriptions – ALC Option (Aluminized Calorized)

(Package Part Number is indicated on the outside of each corresponding carton.)

System Lengths

PTU Body Packages –Aluminized/Aluminized or

20 Ft. Pkg.

30 Ft. Pkg.

40 Ft. Pkg.

50 Ft. Pkg.

 

 

Alumi-Therm/Aluminized

44135020

44136030

44137090

44138090

Part #

 

Each Body Package Includes:

Qty.

Qty.

Qty.

Qty.

42912080

10

Ft. Tube with 24 Hole Flange (Aluminized)

1

1

-

-

42912169

10

Ft. Tube with 6 Hole Flange (Alumi-Therm)

-

-

1

1

41932100

10

Ft. Tube less Flanges (Aluminized)

1

1

3

3

41932050

5 Ft. Tube less Flanges (Aluminized)

-

2

-

2

43319100

Reflector, 9’ 11½”

2

2

4

4

43319050

Reflector, 4’ 11 ½”

-

2

-

2

30462980

Tube Coupling

1

3

3

5

43318000

Tube Hanger/Support Bracket, 13”

2

4

4

6

43980010

Wire Hanger

2

4

4

6

 

Form #43343530

–8–

JJuly 08

Image 9
Contents Installation and Operation Instructions Table of Contents Installer Responsibility SafetyInstallation Requirements General InformationHigh Altitude For Canada onlyMinimum Clearances to Combustibles Minimum Clearances to CombustiblesPacking List SpecificationsNatural GAS Burner Package NumbersPTU 40-200 Body Package Descriptions Reflector, 4’ 11 ½’ End Reflector Accessory Package AccessoriesExhaust Hood Package Emitter Length Body Length Model Typical Layouts PTU / PTS SeriesPoisonous GAS and Soot Hazard Typical Assembly LayoutPTS Series Dimensions PTU Series Joining of Tube Sections Heater AssemblyTypical Assembly Overview PTU 40FT Shown Suspension Hazard Typical Suspension MethodsCUT Hazard Assembly of Tube SectionsMIN 8’ MAX 10’ Between Hangers Assembly of Extension SectionInserting Turbulators Ft. Turbulator Sections Adding ReflectorsAdding Optional Corner Reflector PTS only Adding Optional 90º Elbow PTS onlyAdding Optional U-BEND Reflector PTU only Adding 180U-Bend PTU onlyAttaching Burner BOX Assembly Instructions Connecting the Tiss SystemEnd View Angle Mounted Heaters only Do not USE AN Open Flame of ANY Kind to Test for Leaks GAS Connections and RegulationsKEY Dimensions and Components of the GAS Connections Instructions for Pressure Test Gauge Connection Supply PressureManifold PRESSURE- Combination GAS Valve is Factory SET GAS Control Valve Electrical ConnectionsTH/W Ignition Module Terminal Designations 24VAC/RPS/W GNDLOW Voltage 24V Thermostat Connections Multiple Heaters LOW Voltage 24V Thermostat Connections Single HeaterSingle Heater Venting Vertical Through the Roof VentingSingle Heater Venting Horizontal Through Sidewall #10 Self-Drill Vent Pipe Screws Indirect Venting Unvented Heaters Common Vent DiameterDirect Outside AIR for Combustion AIR for CombustionSide View Lighting and Shutdown InstructionsSequence of Operation Burner Component Locations Electric Shock & Explosion Hazard Cleaning and Maintenance22.0 Troubleshooting GuideForm #43343530 JJuly Replace air switch Restart Troubleshooting Yes Removal of Main Burner and Electrodes Replacing PartsAIR Switch Pressure Check Removal of GAS Valve and Manifold AssemblyIgnition Module Diagnostics Ignition System ChecksTo Check Flame Sensor Circuit Replacement Parts Guide Burner BOX Installation DataLabels/Manual 22c Description Body Components