INSTALLATION
Continued
4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess- flow check valve on propane tank may stop gas flow. If this happens, you may hear a click inside the regulator assembly, this is the check valve closing. To reset the excess flow check valve, close propane supply valve and open again slowly.
5.Check all connections for leaks. Apply mix- ture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected.
| Hose |
Propane Supply |
|
Valve |
|
Propane |
|
Tank | Regulator |
| |
| POL |
| Fitting |
Figure 3 - Regulator Position |
Valve Inlet | Hose |
| |
Figure 4 - Hose and Valve Inlet | |
OPERATION | |
WARNING: Review and un- | |
derstand the warnings in the | |
Safety Information section, page |
2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.
TO START HEATER
1.Before lighting pilot fully close the ball valve (turn knob fully clockwise).
2.Fully open the valve on the propane cylinder and wait 15 seconds before proceding to step 3.
3.Depress red button on safety pilot valve admit- ting gas to the heater. Then push and release the ignitor button until the pilot lights.
4.When the pilot lights, continue to hold the but- ton depressed for 30 seconds, then release.
5.If pilot goes out, wait 5 minutes and repeat the lighting procedure.
6.When the pilot remains lit, open the ball valve (turn knob counterclockwise) to light main burner. Partially close valve to regulate heat output.
Ignitor
Button
Ball Valve
Control Knob
Safety Pilot
Valve
Figure 5 - Starting Heater
TO STOP HEATER
1.Securely close valve on the propane cylinder.
2.Continue to operate heater until all fuel in the hose has burned.
3.Fully close the ball valve.
TO RESTART HEATER
1.Securely close valve at propane cylinder.
2.Wait 5 minutes.
3.Restart following To Start Heater procedure
on page 5.
www.desatech.com | 5 |