Hearth and Home Technologies CNXT4842IT, CNXT4842ILT, CNXT4842IH, CNXT4842ILH IPI Valve Assembly

Page 75

Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/08

Service Parts

 

CNXT4236IT, CNXT4236IH

IPI Valve Assembly Diagram and Parts List Beginning Manufacturing Date: Jan 2006

36 in. Caliber NXT Series

 

Ending Manufacturing Date: Active

IPI Valve Assembly

3

 

4

1

 

 

 

2

 

5

 

 

 

 

6

12

 

 

 

7

 

 

 

 

 

11

 

 

 

 

10

 

 

 

 

9

 

 

 

 

8

 

 

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

Valve Assembly - NG

 

4047-011

 

 

Valve Assembly - LP

 

4047-012

 

1

Shutter Box Top

 

4040-190

 

2

Shutter Box Bottom

 

4040-189

 

3

Pilot Bracket

Pre July 2008

4047-126

 

Post July 2008

4047-144

 

 

 

 

4

Pilot Assembly - NG

 

4021-324

Y

Pilot Assembly - - LP

 

4021-325

Y

 

 

5

Valve Bracket - Upper

 

4040-193

 

6

Valve Bracket - Lower

 

31824

 

7

Flex Ball Valve Asembly

 

302-320A

Y

8

Valve - NG

 

750-500

Y

Valve - LP

 

750-501

Y

 

 

9

3/8 Flare x 3/8 NPT Elbow

 

4021-045

 

10

Threaded Orifice (.120) - NG

 

4021-328

Y

Threaded Orifice (.068) - LP

 

4021-326

Y

 

 

11

Bulkhead

 

4031-192

Y

12

Bulkhead Insulation

 

4021-043

 

Additional service part numbers appear on following page.

 

 

 

 

 

 

 

09/08

 

Service Parts

CNXT4236IT, CNXT4236IH

 

Wall Control Assembly and Parts List

Beginning Manufacturing Date: Jan 2006

 

36 in. Caliber NXT Series

 

Ending Manufacturing Date: Active

1

Wall Control Assembly

 

4

2

 

 

 

 

 

3

 

 

 

 

 

 

 

11

 

 

 

 

 

10

 

 

 

 

 

9

 

 

5

 

 

 

 

 

 

 

8

 

 

 

 

6

7

 

 

 

 

 

 

 

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement

 

Stocked

parts for your appliance please provide model number and serial number. All parts listed

 

in this manual may be ordered from an authorized dealer.

 

 

at Depot

 

 

 

 

 

 

ITEM

DESCRIPTION

 

COMMENTS

PART NUMBER

 

1

Heat Shield

 

 

4047-129

 

2

Remote Wall Cover

 

 

4021-008

 

3

Wall Switch/Key Pad

 

 

HTI-12-007

Y

4

Control Box

 

 

HTI-13-007

Y

5

ON/OFF Rocker Switch

 

 

060-511

Y

6

Solenoid-110V Hi/Lo

 

 

HTI-17-006

Y

7

Control Module

 

 

593-592

Y

8

Wire Assembly

 

 

593-590A

Y

9

Battery Pack

 

 

593-594A

Y

10

Wire Assembly (1Male & 1Fem Term)

 

 

4003-129

 

11

Wire Assembly (Male Terminals)

 

 

4003-128

 

 

Actuator Pins

 

 

HTI-17-116

Y

 

Thermostat Bracket

 

 

27233

 

 

Wall Control Pack

 

 

4047-017

 

 

WSK-MLT Assembly

 

 

4021-338

 

 

 

 

 

 

09/08

C. Service Parts (continued)

75

Image 75
Contents What to do if you smell gas Installation and OperationModels Direct Vent Gas ApplianceHomeowner Reference Information CongratulationsTable of Contents Installer GuideUser Guide Reference Materials Appliance SetupTroubleshooting FinishingCONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyWarranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Gas Fireplace Safety Operating InstructionsYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalLighting Instructions IPI After Fireplace is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceMaintenance Tasks-Qualified Service Technician Typical Appliance System Getting StartedAny such action may cause a fire hazard Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsFraming and Clearances Selecting Appliance LocationModel # Constructing the Appliance Chase ClearancesRough Opening Model Width Height Depth Mantel and Wall Projections MantelsMantel Legs or Wall Projections Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Use of Elbows Vent Information and DiagramsApproved Pipe Vent Table KeyVent Diagrams Top Vent Horizontal TerminationOne Elbow Two 45 Elbows replacing One 90 Elbow Two ElbowsMin Max +H 2 max +H 2+H 3 max Three Elbows Installed VerticallyNo Elbow Top Vent Vertical Termination12 ft 3.66 m min 60 ft 18.29 m max One 45 Elbow Rear Vent Horizontal TerminationTwo Elbows Rear Vent Vertical Termination Min Ft 1.83 m max 12 ft 3.66 m min 60 ft 18.29 m max 17 Flat Baffle Installing Vertical Termination BaffleReplace the glass refer to .H Start the appliance Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingInstalling Ceiling Firestop Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Convert from Top Vent to Rear Vent Appliance PreparationOuter Collar, Remove Four Screws 11 Place Outer Collar on Rear of Appliance 16 Cover Plate-Replace 20 Proper Positioning, Leveling And Securing Of An Securing and Leveling the ApplianceAssemble Pipe Sections DVP Only Installing Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe Sections DVP OnlyAdding Venting Components Assemble Vent Sections SLP OnlySecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling Components SLP onlyCaulk Install Metal Roof Flashing17 Assembling the Storm Collar Assemble and Install Storm CollarSLP-FS Install RF4-8Installing Vertical Termination Cap Installing Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Interior Install Horizontal Termination CapGas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsIntellifire Ignition System Wiring Electrical Service and Repair Junction Box InstallationWSK-MLT Multifunction Wall Switch PrecautionsDetermine Location Intellifire IPI Wiring Diagram Wiring the Wall SwitchHook up the Temperature Sensor Switch for Fan Install the Flame SolenoidInstall the Cover Plate Install the Remote Cover PlateSetting Flame Height/Manifold Pressure Wall Switch Button OperationWSK-MLT Operating Instructions Service Parts List Facing Material FinishingAppliance Setup Place the Rockwool Log AssemblyRemoving Fixed Glass Assembly Install Trim and/or SurroundsInstall Hood Air Shutter SettingTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Will not ignite. If the pilot Reference Materials Appliance Dimension DiagramDVP Vent Components Vent Components DiagramsBEK DVP-BEK2 DVP-TVHW Horizontal Termination Cap DVP-TRAPDVP-HRC-SS Effective Adapter SL-2DVPParts ServiceStocked Service PartsIPI Valve Assembly CNXT4842 Series Log/Grate Assembly Valve Assembly Model Description Optional ComponentsContact Information