Hearth and Home Technologies CNXT4236ILH, CNXT4842ILT, CNXT4842IH, CNXT4842ILH CNXT4842 Series

Page 76

76

Heatilator

 

Service Parts

CNXT4842 SERIES

 

Service Parts Diagram

Beginning Manufacturing Date: N/A

 

42 in. Caliber NXT Series

Ending Manufacturing Date: Active

22

8

9

3

12

10

4

 

 

 

Service Parts

 

CNXT4842 SERIES

 

 

 

Service Parts List

 

Beginning Manufacturing Date: N/A

 

 

42 in. Caliber NXT Series

 

Ending Manufacturing Date: Active

 

 

 

 

 

 

 

 

#

Description of Part

 

CNXT4842IT

CNXT4842ILT

CNXT4842IH

CNXT4842ILH

Qty.

 

 

 

 

 

 

 

 

Exhaust Baffle

4000-197

4000-197

4000-197

4000-197

1

1

Glass Frame Assembly

4040-096

4040-096

4040-096

4040-096

1

 

Exhaust Gasket

31238

31238

31238

31238

1

2

Glass Clip Support Assembly

33858

33858

33858

33858

6

 

Flue Gasket

4000-225

4000-225

4000-225

4000-225

1

3

Intake Collar Assembly

4040-041

4040-041

4040-041

4040-041

1

 

Flue Gasket

4000-225

4000-225

4000-225

4000-225

1

4

Exhaust Collar Assembly

4040-042

4040-042

4040-042

4040-042

1

 

Exhaust Gasket

31238

31238

31238

31238

1

5

Hearth Pan

4040-256

4040-256

4040-256

4040-256

1

6

Burner Support

4040-259

4040-259

4040-259

4040-259

1

7

Grate Retainer

4040-272

4040-272

4040-272

4040-272

1

8

Flue Adapter Plate

25882

25882

25882

25882

1

9

Flue Cover Plate

25901

25901

25901

25901

1

10

Heat Zone Cover Plate

31051

31051

31051

31051

2

C. Service Parts (continued)

• Caliber CNXT Series • 4047-132 Rev U • 11/08

17

2

16

11

19

7

5

6

1

Part number list on following page.

18

10

17

11

20

15

13 14

(Valve Assy.)

21

11

Nailing Flange

31190

31190

31190

31190

4

12

Flue Adapter Plate with Hole

4000-226

4000-226

4000-226

4000-226

1

13

Junction Box (plastic)

4021-013

4021-013

4021-013

4021-013

1

14

Junction Box Cover Plate

4031-222

4031-222

4031-222

4031-222

1

15

Junction Box Radiation Shield

4047-128

4047-128

4047-128

4047-128

1

16

Top Front

29574

29574

29574

29574

1

17

Top Standoffs

4044-111

4044-111

4044-111

4044-111

4

18

Top Pan Shield

4047-109

4047-109

4047-109

4047-109

1

19

Burner Pan Assembly

4047-009

4047-010

4047-009

4047-010

1

 

Burner Neck Gasket

17196

17196

17196

17196

1

 

Installation Instructions/Owner’s Manual

4047-132

4047-132

4047-132

4047-132

1

 

Gas Operations Manual

71680

71680

71680

71680

1

 

Blower Assembly

4047-016

4047-016

4047-016

4047-016

1

20

Blower

GFK160B

GFK160B

GFK160B

GFK160B

1

21

Valve Plate Gasket

4040-198

4040-198

4040-198

4040-198

1

22

Gasket

4031-252

4031-252

4031-252

4031-252

1

06/08

06/08

Image 76
Contents Installation and Operation ModelsDirect Vent Gas Appliance What to do if you smell gasCongratulations Homeowner Reference InformationInstaller Guide Table of ContentsUser Guide Appliance Setup TroubleshootingFinishing Reference MaterialsWarranty Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityWarranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Operating Instructions Gas Fireplace SafetyYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceLighting Instructions IPI Frequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardSelecting Appliance Location Framing and ClearancesModel # Clearances Constructing the Appliance ChaseRough Opening Model Width Height Depth Mantels Mantel and Wall ProjectionsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsTop Vent Horizontal Termination Vent DiagramsOne Elbow Two Elbows Two 45 Elbows replacing One 90 ElbowMin Max +H 2 max +H 2+H 3 max Installed Vertically Three ElbowsTop Vent Vertical Termination No Elbow12 ft 3.66 m min 60 ft 18.29 m max Rear Vent Horizontal Termination One 45 ElbowTwo Elbows Rear Vent Vertical Termination Min Ft 1.83 m max 12 ft 3.66 m min 60 ft 18.29 m max Installing Vertical Termination Baffle 17 Flat BaffleReplace the glass refer to .H Start the appliance Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Installing Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Convert from Top Vent to Rear VentOuter Collar, Remove Four Screws 11 Place Outer Collar on Rear of Appliance 16 Cover Plate-Replace Securing and Leveling the Appliance 20 Proper Positioning, Leveling And Securing Of AnInstalling Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Pipe Sections DVP Only Assemble Pipe Sections DVP OnlyAssemble Vent Sections SLP Only Adding Venting ComponentsAssemble Slip Sections Secure the Vent SectionsInstall Decorative Ceiling Components SLP only Disassemble Vent SectionsInstall Metal Roof Flashing CaulkAssemble and Install Storm Collar 17 Assembling the Storm CollarInstall RF4-8 SLP-FSInstalling Decorative Wall Components SLP only Installing Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap InteriorGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Intellifire Ignition System WiringElectrical Service and Repair Junction Box Installation Electrical InformationPrecautions WSK-MLT Multifunction Wall SwitchDetermine Location Wiring the Wall Switch Intellifire IPI Wiring DiagramInstall the Flame Solenoid Hook up the Temperature Sensor Switch for FanInstall the Remote Cover Plate Install the Cover PlateWall Switch Button Operation Setting Flame Height/Manifold PressureWSK-MLT Operating Instructions Service Parts List Finishing Facing MaterialAppliance Setup Log Assembly Place the RockwoolInstall Trim and/or Surrounds Install HoodAir Shutter Setting Removing Fixed Glass AssemblySymptom Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Will not ignite. If the pilot Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP Vent ComponentsBEK DVP-BEK2 DVP-TVHW DVP-TRAP Horizontal Termination CapDVP-HRC-SS Effective SL-2DVP AdapterService PartsService Parts StockedIPI Valve Assembly CNXT4842 Series Log/Grate Assembly Valve Assembly Optional Components Model DescriptionContact Information