Hearth and Home Technologies ST-550TM-IPI owner manual Junction Box Installation

Page 45

E. Junction Box Installation

The junction box must be wired from the INSIDE of the appliance:

Determine which side of the appliance the junction box is located on.

Pull the electrical wires from outside the appliance through the knockout making sure to use a Romex connector to fasten the electrical wires to the unit.

Pull enough wire into the valve compartment to easily reach the junction box location.

Remove the screw attaching the junction box to the junction box bracket and set it aside.

Route the wire through the knockout in the junction box bracket.

Wire the junction box and reattach it to the bracket by inserting the tab in the slot and attaching with screw previously removed. Ensure that a Romex connector is used to attach the electrical wires to the junction box.

ROMEX CONNECTORS

NOTICE: DO NOT wire

110 VAC to wall switch.

Figure 12.4 Junction Box Detail

F. Wall Switch Installation for Fan (Option-

 

 

 

 

al)

 

 

 

If the box is being wired to a wall mounted switch for use

Minimum 14-3 AWG

 

Switch

with a fan (See Figure 12.5):

 

 

with Ground

 

 

 

 

 

 

The power supply for the appliance must be brought into

 

Red

 

 

Black

Black

 

White

White

 

a switch box.

Junction Box

Green

Green

 

 

 

The power can then be supplied from the switch box

Red Black White Green

 

 

 

to the appliance using a minimum of 14-3 with ground

 

Power

 

 

Switch Box

 

wire.

 

Supply

 

 

 

 

 

 

Wires

At the switch box connect the black (hot) wire and red

 

Knockout

 

 

(switch leg) wire to the wall switch as shown.

 

 

 

 

 

 

At the appliance connect the black (hot), white (neutral)

Red

 

 

 

and green (ground) wires to the junction box as

 

 

 

 

shown.

Figure 12.5 Junction Box Wired to Wall Switch or BC10

• Add a 1/4 in. insulated female connector to the red

 

 

 

 

(switch leg) wire, route it through the knockout in the face

 

 

 

 

of the junction box, and connect to the top fan switch

 

 

 

 

connector (1/4 in. male) as shown.

 

 

 

 

Heat & Glo • ST-550TM-IPI2142-900 Rev. B • 11/08

 

45

Image 45
Contents What to do if you smell gas ModelsHomeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors and FrontsFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Porcelain Firebox Panel CleaningGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseFireplace Opening Non-Combustible MantelVent Termination Minimum Clearances Termination LocationsCovered Alcove Applications Install Support Brackets To Install the Heat ShieldContinue Adding Vent Components Approved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsUse of Flex Vent Vent Diagrams Top Vent Horizontal Termination One ElbowV1 Minimum H1 Maximum V1 Minimum H1 + H2 Maximum Top Vent Horizontal Termination Two ElbowsV1 Minimum H1 + H2 Maximum V1 + V2 Min Top Vent Horizontal Termination Three ElbowsExhaust restrictor Instructions Two Elbows Three Elbows Minimum Maximum + V 2 MinV1 Minimum Maximum V1 + V2 Min Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe SLP Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Securing and Leveling the Appliance Appliance PreparationAssemble Vent Sections Installing Vent PipeSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingApply Sealant TOP & Partial Sides Install RF4-8Install Vertical Termination Cap Install Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination 22 Venting through the wall Install Horizontal Termination CapFuel Conversion Gas InformationGas Pressure Gas ConnectionIntellifire Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical Service and RepairIntellifire Ignition Wiring Diagram with Remote Receiver Wall Switch Installation for Fan Option Junction Box InstallationTo install the Splatter Guard FinishingSplatter Guard To Remove the Splatter Guard To Close the Lower Access Panel15 Non-Combustible Zone Mantel and Wall Projections Combustible MantelFinishing Material Facing MaterialWithout Front Shown Appliance Setup Air Shutter Setting Install Trim Kits and SurroundsTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Remove any contaminants that may have accumulated on Reference Materials Appliance Dimension DiagramVent Components Diagrams Snorkel Black Support Box-Black Wall Thimble-BlackAdapter SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP ST-550TM-IPI Service PartsService Parts List StockedAt Depot Intermittent Pilot Ignition Valve Assembly Contact Information