E. Junction Box Installation
If the box is being wired from the INSIDE of the appliance:
•Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 12.2).
•Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 12.2.
•Make all necessary wire connections to the junction box/ receptacle and reattach the junction box/receptacle to the outer shell.
| Romex | |
| Connector | |
| 14/2WG | |
| Cover Plate | |
| outside firebox | |
WHT |
| |
BLK |
| |
WHT |
| |
BLK | Copper | |
| ||
GRN wire | ground attached | |
to GRN screw with | ||
inside box | ||
| GRN wire | |
NOTICE: DO NOT wire | ||
110 VAC to wall switch. | ||
Figure 12.2 Junction Box Detail |
|
F. Wall Switch Installation for Fan (Optional) |
|
|
| |
If the box is being wired to a wall mounted switch for use |
|
|
| |
with a fan (See Figure 12.3): | Minimum |
| Switch | |
• | The power supply for the appliance must be brought into |
|
| |
with Ground |
|
| ||
| a switch box. |
| Red |
|
|
| Black | Black | |
|
|
| White | White |
• | The power can then be supplied from the switch box to the | Junction Box | Green | Green |
|
|
| ||
| appliance using a minimum of | Red Black White Green |
|
|
• | At the switch box connect the black (hot) wire and red |
| Power | |
| Switch Box | |||
| Supply | |||
| (switch leg) wire to the wall switch as shown. |
|
| |
|
|
| Wires | |
• | At the appliance connect the black (hot), white (neutral) |
| Knockout |
|
| and green (ground) wires to the junction box as shown. |
|
|
|
• Add a 1/4 in. insulated female connector to the red (switch | Red |
|
| |
|
|
| ||
| leg) wire, route it through the knockout in the face of the |
|
|
|
| junction box, and connect to the top fan switch connector | Figure 12.3 Junction Box Wired to Wall Switch or BC10 | ||
| (1/4 in. male) as shown. | |||
| Heat & Glo • | 49 |