Hearth and Home Technologies 6000GLX-IPI-S Rear Vent Horizontal Termination Two Elbows

Page 30

Rear Vent - Horizontal Termination - (continued)

Two Elbows

H1 Maximum

V1 Minimum

 

H2

H1 + H2 Maximum

1 ft.

305 mm

Back to Back

1 ft.

 

 

305 mm

2 ft.

610 mm

90º Elbows

 

 

 

 

 

 

 

 

 

 

2 ft.

610 mm

6 in.

152 mm

2 ft.

 

 

610 mm

4 ft.

1.2 m

3 ft.

914 mm

1 ft.

305 mm

2 ft.

 

 

610 mm

5 ft.

1.5 m

3 ft.

914 mm

2 ft.

610 mm

4 ft.

 

 

1.2 m

7 ft.

2.1 m

3 ft.

914 mm

3 ft.

914 mm

9 ft.

 

 

2.7 m

12 ft.

3.7 m

3 ft.

914 mm

4 ft

1.2 m

18 ft.

 

 

5.5 m

20 ft.*

6.1 m*

V1 + H1 + H2 = 40 ft (12.2 m) Maximum

H1

= 3 ft (914 mm) Maximum

 

 

*H1 + H2 = 20 ft (6.1 m) Maximum

 

 

H2

Figure 7.15

Three Elbows

INSTALLED

HORIZONTALLY

V1

H1

H1 Maximum

V1 Minimum

H2+ H3

H1+ H2+ H3 Max.

1 ft.

305 mm

Back to Back

1 ft.

305 mm

2 ft.

610 mm

90º Elbows

 

 

 

 

 

 

2 ft.

610 mm

6 in.

152 mm

1.5 ft.

457 mm

3.5 ft.

1.1 m

 

 

 

 

 

 

 

 

3 ft.

914 mm

1 ft.

305 mm

2 ft.

610 mm

5 ft.

1.5 m

3 ft.

914 mm

2 ft.

610 mm

4 ft.

1.2 m

7 ft.

2.1 m

3 ft.

914 mm

3 ft.

914 mm

9 ft.

2.7 m

12 ft.

3.7 m

3 ft.

914 mm

4 ft.

1.2 m

12 ft.

3.7 m

15 ft.

4.6 m

V1+ H1+ H2+ H3= 40 ft (12.2 m) Maximum

H1= 3 ft (914 mm) Maximum

 

 

H1+ H2+ H3= 20 ft (6.1 m) Maximum

 

 

H3H2

V1

H1

Figure 7.16

30

Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R2101-900 Rev. S • 12/08

Image 30
Contents What to do if you smell gas Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsCONDITIONS, Exclusions & Limitation of Liability Limited Lifetime Warranty Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceLighting Instructions IPI Turn off all electric power to the applianceOn position. The ON/OFF switch may Final inspection byFrequently Asked Questions After Fireplace is LitMaintenance and Service Venting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsIPI Pilot Flame Patterns Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Any such action may cause a fire hazardFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Combustible MantelsCombustible Mantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Vent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsVent Diagrams Top Vent Horizontal Termination V1 Minimum H1 MaximumV1 Minimum H1 + H2 Maximum Top Vent Horizontal Termination Three Elbows Min MaxBreak Here Top Vent Vertical Termination Two ElbowsMaximum + V 2 Min Top Vent Vertical Termination Three Elbows H1 + H2 V1 + V2 Minimum H1 + H2 MaximumPage Rear Vent Horizontal Termination Two Elbows H1 Maximum V1 Minimum H1 + H2 MaximumH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max Rear Vent Vertical Termination One Elbow H1 + H2 Maximum V1 MinimumRear Vent Vertical Termination Three Elbows V1 Minimum H1 + H2 + H3Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPFlat Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-Zone-Gas Kit Vaulted Ceiling InstallationAppliance Preparation Choosing the Top or Rear VentProceed to . C Installing the Non-combustible Board Rear Vent Securing and Leveling the ApplianceAssemble Vent Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall RF4-8 SLP-FSInstall Vertical Termination Cap Install Decorative Wall Components SLP onlyHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe Ansi Z223.1 and CAN/CGA-B149 installation codesRefer to of this manual Gas Pressure Gas InformationFuel Conversion Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntellifire Ignition System Wiring Electrical InformationElectrical Service and Repair Intellifire Pilot Ignition IPI Wiring DiagramJunction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialDoors Finish Door FIT Material See Maximum ThicknessAppliance Setup Ember Placement Placement of EmbersLog Assembly LOGS-6000GLX LOGS-6000GLXLP Install the Log Assembly11 Front View 17 Front View Air Shutter Setting Install the MeshInstall Trim and/or Surround Air Shutter SettingsTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLocation Inches Millimeters Vent Components Diagrams DVP vent componentsHorizontal Termination Cap DVP vent components302 mm 787 mm 13-1/4 367 mm 24-5/8 625 mm 27-1/2 127 mmRoof Flashing Multi-pak 13-3/4 11-7/8 349 mm 13-3/4 13-7/8 352 mm 349 mmDVP-TVHW DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Elbow 165 mm165 mm 222 mm 235 mm 152 mm 168 mm 251 mmCathedral Ceiling Vertical Snorkel Support Box-BlackBlack Termination CapLog Set Assembly Service PartsService Parts List StockedAt Depot 6000GLX-IPI-R,-S 6000GLX-IPI-R,S Contact Information