Hearth and Home Technologies CASTILE-MBK1, CASTILE-PMH1 6Mobile Home, Castile Pellet Stove

Page 16

R

Castile Pellet Stove

6Mobile Home

A. Mobile Home Installation

You must use a Quadra-Fire Outside Air Kit for installation in a mobile home.

1.An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while the appliance is in use to prevent room air starvation which causes smoke spillage. Smoke spillage can also set off smoke alarms.

CAUTION

Maintain structural integrity of mobile home:

Floor, wall, ceiling and/or roof. Do NOT cut through:

Floor joist, wall, studs or ceiling trusses.

Any supporting material that would affect the structural integrity.

2.The combustion air duct system must be made of metal. It must permit zero clearance to combustible construction and prevent material from dropping into the inlet or into the area beneath the dwelling and contain a rodent screen.

3.The appliance must be secured to the mobile home structure by bolting it to the floor (using lag bolts). Use the same holes that secured the appliance to the shipping pallet.

4.The appliance must be grounded with #8 solid copper grounding wire or equivalent, terminated at each end with an NEC approved grounding device.

5.Refer to clearances to combustibles and floor protection requirements on pages 8 & 9 for listings to combus- tibles and appropriate chimney systems.

6.Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the the exterior of the structure.

7.Follow the chimney manufacturer’s instructions when installing the vent system for use in a mobile home.

8.Installation shall be in accordance with the Manufactur- ers Home & Safety Standard (HUD) CFR 3280, Part 24.

WARNING

Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.

CAUTION

Never draw outside combustion air from:

Wall, floor or ceiling cavity

Enclosed space such as an attic or garage

 

Spark Arrestor Cap

Storm Collar

 

 

Roof Flashing

Joist Shield/Firestop

Approved Class “L”

 

or “PL” Pellet Pipe

Figure 16.1

WARNING

Never install in a sleeping room.

Page 16

250-6422E

September 1, 2008

Image 16
Contents Castile Pellet Stove Castile Pellet Stove Location Back side of left side panelTable of Contents Listing and Code Approvals Design, Installation & Location Considerations Fire SafetyGetting Started Appliance LocationInspect Appliance & Components and Pre-Use Check List Castile Pellet Stove Tools And Supplies NeededFire Risk 3Dimensions and Clearances Appliance DimensionsCastile Pellet Stove Clearances to Combustibles UL and ULC Castile Pellet Stove Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsHearth Pad Requirements Chimney and Exhaust Connection 4Vent InformationVenting Termination Requirements Pipe Selection Chart Castile Pellet Stove Equivalent Feet of PipeExample of 3 Elbow-Rear Vent Termination Calculaton See Figure5Venting Systems AlcoveDegree Straight OutCastile Pellet Stove Through The Wall Castile Pellet Stove Vertical Through The Wall & VerticalCastile Pellet Stove Masonry Alternate Masonry6Mobile Home 7Appliance Set-Up Outside Air Kit InstructionsTop Vent Adapter Installation Rear Vent and Rear Vent to Top Vent Adapter InstallationInstalling the Top Vent Adapter Castile Pellet Stove Leg Leveling SystemOptional TOP LOG Castile Pellet Stove Thermostat Installation 8Operating Instructions Fuel Size And Material General Operating InformationFire Characteristics Feed Rate Adjustment InstructionsCastile Pellet Stove Before Your First Fire Starting Your First FireFrequently Asked Questions Castile Pellet Stove Iginition CyclesSymption TroubleshootingPossible Cause Corrective Action Page Symptoms Possible Cause Corrective Action Quick Reference Maintenance Chart 10Maintaining & Servicing Your ApplianceFrequency Daily Weekly Monthly YearlyCleaning Firepot with Cleaning Rod & Firepot Scraper Cleaning Ash PanCleaning Heat Exchanger Chambers & Drop Tube Ash Removal from FireboxCleaning Beneath Heat Exchanger Cleaning the Exhaust PathCleaning the Hopper Cleaning the GlassCleaning Convection Blower Requires No Lubrication Cleaning Exhaust Blower Requires No LubricationCleaning the Top Vent Adapter Preparing Firebox for Non-Burn Season Frequency YearlyCastile Pellet Stove High Ash Fuel Content Maintenance Convection Blower ReplacementCombustion Blower Replacement Remove 6 screws Combustion BlowerIgniter Replacement Glass Replacement Component Function Vacuum Switch Wiring Harness See .1 belowSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FCastile Pellet Stove Component Locations Castile Pellet Stove Exploded Views Description Part NumberPart Description Castile Pellet Stove Service Parts and Accessories Service PartsCastile Pellet Stove Accessories AppliancesCastile Pellet Stove Service and Maintenance Log Date of Service Performed By Description of ServiceCastile Pellet Stove Service and Maintenance Log Cont’d Castile Pellet Stove Homeowner’s Notes Castile Pellet Stove Warranty Policy EPAHearth & Home Technologies Limited Warranty Cont’d T O T O Telephone

CASTILE-PMH1, CASTILE-CSB, CASTILE-MBK1, CASTILE-CWL specifications

Hearth and Home Technologies is renowned for its innovative and efficient heating solutions, among which the CASTILE line of products stands out. The CASTILE-CWL, CASTILE-MBK1, CASTILE-CSB, and CASTILE-PMH1 represent a blend of tradition and modern technology, designed to enhance home comfort while prioritizing energy efficiency and ease of use.

The CASTILE-CWL is a versatile unit featuring a sleek design that fits effortlessly into various decors. It incorporates an advanced combustion system that promotes cleaner burning, reducing emissions while delivering robust heat output. Its large hopper capacity minimizes the frequency of refueling, making it ideal for continuous heating. Additionally, the intuitive control panel offers user-friendly operation, allowing homeowners to set their ideal temperature easily.

Next, the CASTILE-MBK1 model boasts a unique design compatible with many different settings. It features enhanced insulation that ensures maximum heat retention and minimizes heat loss. The automatic ignition and advanced safety features ensure that use is not only efficient but also worry-free. Moreover, this model includes a programmable thermostat, giving users the ability to set heating schedules according to their preferences.

The CASTILE-CSB is particularly notable for its integration of modern technology with traditional aesthetics. Its compact design doesn’t skimp on performance, and its high-efficiency rating translates to lower energy bills. With features like a quiet operation system and a digital display for monitoring, the CASTILE-CSB is perfect for homes of any size. The model also offers customizable options for different finishes, allowing homeowners to match their heating source with their interior design.

Finally, the CASTILE-PMH1 rounds out this impressive lineup. This model is designed for reliable performance, providing consistent warmth with its state-of-the-art heat exchanger technology. The chimney venting system enables optimal heat distribution throughout the home while maintaining safety standards. Additionally, it includes features such as an easy-clean design and multiple heat settings, allowing users to tailor their heating experience.

In summary, Hearth and Home Technologies’ CASTILE product line offers an impressive combination of style, efficiency, and advanced features. Each model caters to specific needs while upholding the brand's commitment to quality and innovation, ensuring homeowners can enjoy a warm and inviting living environment.