Hearth and Home Technologies CASTILE-CWL, CASTILE-CSB Castile Pellet Stove Before Your First Fire

Page 22

R

Castile Pellet Stove

C. Before Your First Fire

1.First, make sure your appliance has been properly installed and that all safety requirements have been met. Pay particular attention to the fire protection, venting and thermostat installation instructions.

2.Double check that the ash pan and firebox are empty!

3.Check the position of the thermocouple, located above the firepot, and make sure that it protrudes approximately 3/4 inch (19mm) into the firepot. IMPORTANT DETAIL:

The tip of the thermocouple must be in contact with the inside end of the thermocouple cover.

E. Fire Characteristics

A properly adjusted fire with the heat output control switch set on “high” has a short active flame pattern that extends out of the firepot approximately 4 inches (102mm). If the fire has tall flames with black tails and seems somewhat lazy, the feed rate will need to be reduced. This is done by sliding the fuel adjustment control rod down, which will reduce the feed. If the fire is not 4 inches (102mm) tall, slide the fuel adjustment control rod up to increase the feed. A medium and low setting will give a shorter flame. The flame will rise and fall somewhat. This is normal.

4. Close the front door.

D. Starting Your First Fire

1.A thermostat is required for proper operation of this appliance, except for corn. At this time, fill the hopper with pellets, set the thermostat to its lowest setting. Plug the power cord into nearby outlet.

2.The exhaust blower will stay on for approximately 18 minutes even though the thermostat is not calling for heat. This is normal.

3.Locate the heat output control switch mounted on the back of the appliance in the upper right corner. See Figure 21.1 on page 21. Turn it to the “high” setting by pushing the top of the control switch in and then adjust the thermostat to its highest setting. Open the right side panel and the red call light located behind the control box will be on. See Figure 22.1. This indicates the thermostat is calling for heat.

4.The fuel feed system and the igniter should now be on.

5.For your first fire it will be necessary to press the reset button once approximately 2 minutes after start up and again in 5 minutes. This will fill the feed system and allow the appliance to begin dropping pellets. The appliance will continue to run as long as the thermostat is calling for heat.

6.Once the appliance has ignited, let it burn for approximately 15 minutes, then set the thermostat to the desired room temperature. Adjust the heat output control switch to the desired setting.

F. Feed Rate Adjustment Instructions

The feed adjustment control rod is factory set, and should be adequate for most fuels. However, if the flame height is too high or too low, you will need to adjust the feed rate. Wait until the appliance has been burning for 15 minutes before making your adjustments and allow 15 minutes for feed adjustment to take effect.

1.Loosen the set screw 1/4 to 1/2 turn during set-up of appliance. This will allow movement of the feed adjustment control rod. Do not re-tighten set screw.

Figure 22.2.

2.Loosen the wing nut. Figure 22.3.

3.Adjust the feed adjustment control rod upward towards the "+" symbol to increase the feed rate and flame height or down towards the "-" symbol, to decrease the feed rate and flame height. Figure 22.3.

4.Re-tighten the wing nut.

Set Screw

Figure 22.2

Red Call Light is located on top of Junction Box behind the Control Box.

Control

Box

 

Increase

Fuel Adjustment

Decrease

Control Rod

 

Wing Nut

 

Figure 22.1

 

Figure 22.3

 

 

 

 

 

 

Page 22

250-6422E

September 1, 2008

Image 22
Contents Castile Pellet Stove Castile Pellet Stove Location Back side of left side panelTable of Contents Listing and Code Approvals Getting Started Design, Installation & Location ConsiderationsFire Safety Appliance LocationInspect Appliance & Components and Pre-Use Check List Castile Pellet Stove Tools And Supplies NeededFire Risk 3Dimensions and Clearances Appliance DimensionsCastile Pellet Stove Clearances to Combustibles UL and ULC Castile Pellet Stove Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsHearth Pad Requirements Chimney and Exhaust Connection 4Vent InformationVenting Termination Requirements Example of 3 Elbow-Rear Vent Termination Calculaton Pipe Selection ChartCastile Pellet Stove Equivalent Feet of Pipe See Figure5Venting Systems AlcoveDegree Straight OutCastile Pellet Stove Through The Wall Castile Pellet Stove Vertical Through The Wall & VerticalCastile Pellet Stove Masonry Alternate Masonry6Mobile Home 7Appliance Set-Up Outside Air Kit InstructionsInstalling the Top Vent Adapter Top Vent Adapter InstallationRear Vent and Rear Vent to Top Vent Adapter Installation Castile Pellet Stove Leg Leveling SystemOptional TOP LOG Castile Pellet Stove Thermostat Installation 8Operating Instructions Fuel Size And Material General Operating InformationCastile Pellet Stove Before Your First Fire Fire CharacteristicsFeed Rate Adjustment Instructions Starting Your First FireFrequently Asked Questions Castile Pellet Stove Iginition CyclesSymption TroubleshootingPossible Cause Corrective Action Page Symptoms Possible Cause Corrective Action Frequency Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Daily Weekly Monthly YearlyCleaning Heat Exchanger Chambers & Drop Tube Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Ash Pan Ash Removal from FireboxCleaning the Hopper Cleaning Beneath Heat ExchangerCleaning the Exhaust Path Cleaning the GlassCleaning the Top Vent Adapter Cleaning Convection Blower Requires No LubricationCleaning Exhaust Blower Requires No Lubrication Preparing Firebox for Non-Burn Season Frequency YearlyCastile Pellet Stove High Ash Fuel Content Maintenance Convection Blower ReplacementCombustion Blower Replacement Remove 6 screws Combustion BlowerIgniter Replacement Glass Replacement Component Function Snap Disc #1 Convection Blower 110F Vacuum SwitchWiring Harness See .1 below Snap Disc #2 Fuel Delivery Interrupt 250FCastile Pellet Stove Component Locations Castile Pellet Stove Exploded Views Description Part NumberPart Description Castile Pellet Stove Service Parts and Accessories Service PartsCastile Pellet Stove Accessories AppliancesCastile Pellet Stove Service and Maintenance Log Date of Service Performed By Description of ServiceCastile Pellet Stove Service and Maintenance Log Cont’d Castile Pellet Stove Homeowner’s Notes Castile Pellet Stove Warranty Policy EPAHearth & Home Technologies Limited Warranty Cont’d T O T O Telephone

CASTILE-PMH1, CASTILE-CSB, CASTILE-MBK1, CASTILE-CWL specifications

Hearth and Home Technologies is renowned for its innovative and efficient heating solutions, among which the CASTILE line of products stands out. The CASTILE-CWL, CASTILE-MBK1, CASTILE-CSB, and CASTILE-PMH1 represent a blend of tradition and modern technology, designed to enhance home comfort while prioritizing energy efficiency and ease of use.

The CASTILE-CWL is a versatile unit featuring a sleek design that fits effortlessly into various decors. It incorporates an advanced combustion system that promotes cleaner burning, reducing emissions while delivering robust heat output. Its large hopper capacity minimizes the frequency of refueling, making it ideal for continuous heating. Additionally, the intuitive control panel offers user-friendly operation, allowing homeowners to set their ideal temperature easily.

Next, the CASTILE-MBK1 model boasts a unique design compatible with many different settings. It features enhanced insulation that ensures maximum heat retention and minimizes heat loss. The automatic ignition and advanced safety features ensure that use is not only efficient but also worry-free. Moreover, this model includes a programmable thermostat, giving users the ability to set heating schedules according to their preferences.

The CASTILE-CSB is particularly notable for its integration of modern technology with traditional aesthetics. Its compact design doesn’t skimp on performance, and its high-efficiency rating translates to lower energy bills. With features like a quiet operation system and a digital display for monitoring, the CASTILE-CSB is perfect for homes of any size. The model also offers customizable options for different finishes, allowing homeowners to match their heating source with their interior design.

Finally, the CASTILE-PMH1 rounds out this impressive lineup. This model is designed for reliable performance, providing consistent warmth with its state-of-the-art heat exchanger technology. The chimney venting system enables optimal heat distribution throughout the home while maintaining safety standards. Additionally, it includes features such as an easy-clean design and multiple heat settings, allowing users to tailor their heating experience.

In summary, Hearth and Home Technologies’ CASTILE product line offers an impressive combination of style, efficiency, and advanced features. Each model caters to specific needs while upholding the brand's commitment to quality and innovation, ensuring homeowners can enjoy a warm and inviting living environment.