Hearth and Home Technologies CASTILE-PMH1, CASTILE-MBK1, CASTILE-CWL, CASTILE-CSB owner manual

Page 25

R

Castile Pellet Stove

Symptom

Possible Cause

Corrective Action

Slow or smoky start-up

Dirty exhaust and/or venting system.

Check for ash build up in unit, includ-

(Cont’d)

 

ing behind rear panels, firebox, heat

 

 

exchanger, exhaust blower and venting.

Feed system fails to

Out of fuel.

Check hopper, fill with fuel.

start.

#2 snap disc may be defective.

Replace snap disc. Firebox door must be

 

 

 

closed securely.

 

Vacuum switch not closing. No vacuum.

Check exhaust blower is plugged in and

 

 

operating.

 

 

Check vacuum switch is plugged in.

 

 

Check vacuum hose is in good condition,

 

 

clear and connected at both ends.

 

 

Check thermocouple is in good condition

 

 

and plugged in properly.

 

 

Make sure venting system is clean.

 

 

NOTE: High winds blowing into the vent-

 

 

ing system can pressurize the firebox

 

 

causing loss of vacuum.

 

Feed system jammed or blocked.

Empty hopper of fuel. Use a wet/dry

 

 

vacuum cleaner to remove remaining fuel,

 

 

from hopper, including feed tube.

 

 

Check feed chute for obstructions.

 

 

Loosen 2 feed assembly mounting screws

 

Feed spring not turning with feed motor.

and lightly shake feed assembly.

 

Check that set screw is tight on feed

 

 

 

Feed motor defective or not plugged in.

spring shaft at end of feed motor.

 

Check connections on feed motor, replace

 

 

 

 

if defective.

No call light. Unit

Thermostat not set to a high enough tempera-

Adjust thermostat above room tempera-

does not begin start

ture.

ture.

sequence.

Snap Disc #3 tripped.

Reset snap disc.

 

 

No power.

Connect to power.

 

Fuse blown.

Replace fuse.

 

Connections at thermostat and/or appliance not

Check connections at thermostat and

 

making proper contact.

appliance.

 

Defective thermostat or thermostat wiring.

Replace thermostat or wiring.

 

 

NOTE: To test thermostat and wiring, use

 

 

a jumper wire at the thermostat block on

 

 

the unit to by-pass thermostat and wiring.

 

Control box defective.

Replace control box.

Unit fails to shut off.

Call light on.

Turn thermostat off.

 

 

If call light does not go out, disconnect

 

 

thermostat wires from unit. If call light

 

 

does go out, thermostat or wires are

 

 

defective.

 

 

 

September 1, 2008

250-6422E

Page 25

Image 25
Contents Castile Pellet Stove Location Back side of left side panel Castile Pellet StoveTable of Contents Listing and Code Approvals Fire Safety Design, Installation & Location ConsiderationsGetting Started Appliance LocationInspect Appliance & Components and Pre-Use Check List Castile Pellet Stove Tools And Supplies NeededFire Risk Appliance Dimensions 3Dimensions and ClearancesCastile Pellet Stove Clearances to Combustibles UL and ULC Castile Pellet Stove Hearth Pad Requirements UL and ULC Exception for Horizontal InstallationsHearth Pad Requirements Chimney and Exhaust Connection 4Vent InformationVenting Termination Requirements Castile Pellet Stove Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculaton See FigureAlcove 5Venting SystemsDegree Straight OutCastile Pellet Stove Through The Wall Through The Wall & Vertical Castile Pellet Stove VerticalAlternate Masonry Castile Pellet Stove Masonry6Mobile Home Outside Air Kit Instructions 7Appliance Set-UpRear Vent and Rear Vent to Top Vent Adapter Installation Top Vent Adapter InstallationInstalling the Top Vent Adapter Castile Pellet Stove Leg Leveling SystemOptional TOP LOG Castile Pellet Stove Thermostat Installation Fuel Size And Material General Operating Information 8Operating InstructionsFeed Rate Adjustment Instructions Fire CharacteristicsCastile Pellet Stove Before Your First Fire Starting Your First FireCastile Pellet Stove Iginition Cycles Frequently Asked QuestionsSymption TroubleshootingPossible Cause Corrective Action Page Symptoms Possible Cause Corrective Action 10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartFrequency Daily Weekly Monthly YearlyCleaning Ash Pan Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Heat Exchanger Chambers & Drop Tube Ash Removal from FireboxCleaning the Exhaust Path Cleaning Beneath Heat ExchangerCleaning the Hopper Cleaning the GlassCleaning Exhaust Blower Requires No Lubrication Cleaning Convection Blower Requires No LubricationCleaning the Top Vent Adapter Preparing Firebox for Non-Burn Season Frequency YearlyConvection Blower Replacement Castile Pellet Stove High Ash Fuel Content MaintenanceRemove 6 screws Combustion Blower Combustion Blower ReplacementIgniter Replacement Glass Replacement Component Function Wiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FCastile Pellet Stove Component Locations Description Part Number Castile Pellet Stove Exploded ViewsPart Description Service Parts Castile Pellet Stove Service Parts and AccessoriesCastile Pellet Stove Appliances AccessoriesDate of Service Performed By Description of Service Castile Pellet Stove Service and Maintenance LogCastile Pellet Stove Service and Maintenance Log Cont’d Castile Pellet Stove Homeowner’s Notes EPA Castile Pellet Stove Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Telephone T O T O

CASTILE-PMH1, CASTILE-CSB, CASTILE-MBK1, CASTILE-CWL specifications

Hearth and Home Technologies is renowned for its innovative and efficient heating solutions, among which the CASTILE line of products stands out. The CASTILE-CWL, CASTILE-MBK1, CASTILE-CSB, and CASTILE-PMH1 represent a blend of tradition and modern technology, designed to enhance home comfort while prioritizing energy efficiency and ease of use.

The CASTILE-CWL is a versatile unit featuring a sleek design that fits effortlessly into various decors. It incorporates an advanced combustion system that promotes cleaner burning, reducing emissions while delivering robust heat output. Its large hopper capacity minimizes the frequency of refueling, making it ideal for continuous heating. Additionally, the intuitive control panel offers user-friendly operation, allowing homeowners to set their ideal temperature easily.

Next, the CASTILE-MBK1 model boasts a unique design compatible with many different settings. It features enhanced insulation that ensures maximum heat retention and minimizes heat loss. The automatic ignition and advanced safety features ensure that use is not only efficient but also worry-free. Moreover, this model includes a programmable thermostat, giving users the ability to set heating schedules according to their preferences.

The CASTILE-CSB is particularly notable for its integration of modern technology with traditional aesthetics. Its compact design doesn’t skimp on performance, and its high-efficiency rating translates to lower energy bills. With features like a quiet operation system and a digital display for monitoring, the CASTILE-CSB is perfect for homes of any size. The model also offers customizable options for different finishes, allowing homeowners to match their heating source with their interior design.

Finally, the CASTILE-PMH1 rounds out this impressive lineup. This model is designed for reliable performance, providing consistent warmth with its state-of-the-art heat exchanger technology. The chimney venting system enables optimal heat distribution throughout the home while maintaining safety standards. Additionally, it includes features such as an easy-clean design and multiple heat settings, allowing users to tailor their heating experience.

In summary, Hearth and Home Technologies’ CASTILE product line offers an impressive combination of style, efficiency, and advanced features. Each model caters to specific needs while upholding the brand's commitment to quality and innovation, ensuring homeowners can enjoy a warm and inviting living environment.