Hearth and Home Technologies CASTILE-PMH1 Getting Started, Fire Safety, Appliance Location

Page 5

R

Castile Pellet Stove

2 Getting Started

A.Design, Installation & Location Considerations

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends NFI certified profession- als, or technicians supervised by an

NFI certified professional.

1. Appliance Location

Consideration must be given to safety, convenience, traffic flow, and the fact that the appliance will need a chimney and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation.

If you are not using an existing chimney, place the appliance in a location to maintain a clear passage for the installation of any listed and approved pellet venting system. This appli- ance may be vented vertically or horizontally.

Maintain specified vent clearance to comubstible require- ments listed by the pellet manufactures venting instructions and all clearance to combustivles listed in this manual.

Check with your local building code agency before you begin your installation. Be sure local building codes do not super- sede UL specifications and always obtain a building permit so that insurance protection benefits cannot be unexpectedly cancelled. If any assistance is required during installation, please contact your local dealer.

We recommend that a qualified building inspector and your insurance company representative review your plans before and after installation.

2. Thermostat Location

The thermostat’s location will have some effect on the appliance’s operation. When the thermostat is located close to the appliance, it may require a slightly higher temperature setting to keep the rest of the house comfortable. If the thermostat location is in an adjacent room or on a different floor level, you will notice higher temperatures near the appliance.

CAUTION

Do NOT connect this unit to a chimney flue servicing another appliance.

Do NOT connect to any air distributon duct or system.

B. Fire Safety

Maintain the designated clearances to combustibles. Insulation must not touch the chimney. You must maintain the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat removal from the area. Insulation in this space will cause a heat buildup, which may ignite wood framing. NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction.

To provide reasonable fire safety, the following should be given serious consideration:

1.Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the heating appliance and close to the sleeping areas. Follow the smoke detector manufacturer’s placement and installation instructions, and be sure to maintain regularly.

2.A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers.

3.A practiced evacuation plan, consisting of at least 2 escape routes.

4.A plan to deal with a hopper fire as follows: In the event of a hopper fire:

a.Evacuate the house immediately.

b.Notify fire department.

WARNING

Fire Hazard.

Do not operate appliance before reading and understanding operating instructions.

Failure to operate appliance properly may cause a house fire.

September 1, 2008

250-6422E

Page 5

Image 5
Contents Castile Pellet Stove Location Back side of left side panel Castile Pellet StoveTable of Contents Listing and Code Approvals Fire Safety Design, Installation & Location ConsiderationsGetting Started Appliance LocationFire Risk Castile Pellet Stove Tools And Supplies NeededInspect Appliance & Components and Pre-Use Check List Appliance Dimensions 3Dimensions and ClearancesCastile Pellet Stove Clearances to Combustibles UL and ULC Hearth Pad Requirements Exception for Horizontal InstallationsCastile Pellet Stove Hearth Pad Requirements UL and ULC Venting Termination Requirements 4Vent InformationChimney and Exhaust Connection Castile Pellet Stove Equivalent Feet of Pipe Pipe Selection ChartExample of 3 Elbow-Rear Vent Termination Calculaton See FigureAlcove 5Venting SystemsCastile Pellet Stove Through The Wall Straight OutDegree Through The Wall & Vertical Castile Pellet Stove VerticalAlternate Masonry Castile Pellet Stove Masonry6Mobile Home Outside Air Kit Instructions 7Appliance Set-UpRear Vent and Rear Vent to Top Vent Adapter Installation Top Vent Adapter InstallationInstalling the Top Vent Adapter Castile Pellet Stove Leg Leveling SystemOptional TOP LOG Castile Pellet Stove Thermostat Installation Fuel Size And Material General Operating Information 8Operating InstructionsFeed Rate Adjustment Instructions Fire CharacteristicsCastile Pellet Stove Before Your First Fire Starting Your First FireCastile Pellet Stove Iginition Cycles Frequently Asked QuestionsPossible Cause Corrective Action TroubleshootingSymption Page Symptoms Possible Cause Corrective Action 10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartFrequency Daily Weekly Monthly YearlyCleaning Ash Pan Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Heat Exchanger Chambers & Drop Tube Ash Removal from FireboxCleaning the Exhaust Path Cleaning Beneath Heat ExchangerCleaning the Hopper Cleaning the GlassCleaning Exhaust Blower Requires No Lubrication Cleaning Convection Blower Requires No LubricationCleaning the Top Vent Adapter Preparing Firebox for Non-Burn Season Frequency YearlyConvection Blower Replacement Castile Pellet Stove High Ash Fuel Content MaintenanceRemove 6 screws Combustion Blower Combustion Blower ReplacementIgniter Replacement Glass Replacement Component Function Wiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FCastile Pellet Stove Component Locations Description Part Number Castile Pellet Stove Exploded ViewsPart Description Service Parts Castile Pellet Stove Service Parts and AccessoriesCastile Pellet Stove Appliances AccessoriesDate of Service Performed By Description of Service Castile Pellet Stove Service and Maintenance LogCastile Pellet Stove Service and Maintenance Log Cont’d Castile Pellet Stove Homeowner’s Notes EPA Castile Pellet Stove Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Telephone T O T O

CASTILE-PMH1, CASTILE-CSB, CASTILE-MBK1, CASTILE-CWL specifications

Hearth and Home Technologies is renowned for its innovative and efficient heating solutions, among which the CASTILE line of products stands out. The CASTILE-CWL, CASTILE-MBK1, CASTILE-CSB, and CASTILE-PMH1 represent a blend of tradition and modern technology, designed to enhance home comfort while prioritizing energy efficiency and ease of use.

The CASTILE-CWL is a versatile unit featuring a sleek design that fits effortlessly into various decors. It incorporates an advanced combustion system that promotes cleaner burning, reducing emissions while delivering robust heat output. Its large hopper capacity minimizes the frequency of refueling, making it ideal for continuous heating. Additionally, the intuitive control panel offers user-friendly operation, allowing homeowners to set their ideal temperature easily.

Next, the CASTILE-MBK1 model boasts a unique design compatible with many different settings. It features enhanced insulation that ensures maximum heat retention and minimizes heat loss. The automatic ignition and advanced safety features ensure that use is not only efficient but also worry-free. Moreover, this model includes a programmable thermostat, giving users the ability to set heating schedules according to their preferences.

The CASTILE-CSB is particularly notable for its integration of modern technology with traditional aesthetics. Its compact design doesn’t skimp on performance, and its high-efficiency rating translates to lower energy bills. With features like a quiet operation system and a digital display for monitoring, the CASTILE-CSB is perfect for homes of any size. The model also offers customizable options for different finishes, allowing homeowners to match their heating source with their interior design.

Finally, the CASTILE-PMH1 rounds out this impressive lineup. This model is designed for reliable performance, providing consistent warmth with its state-of-the-art heat exchanger technology. The chimney venting system enables optimal heat distribution throughout the home while maintaining safety standards. Additionally, it includes features such as an easy-clean design and multiple heat settings, allowing users to tailor their heating experience.

In summary, Hearth and Home Technologies’ CASTILE product line offers an impressive combination of style, efficiency, and advanced features. Each model caters to specific needs while upholding the brand's commitment to quality and innovation, ensuring homeowners can enjoy a warm and inviting living environment.