State Industries 705 Series 200, U287-084 Installation Instructions, General Instructions

Page 13

Installation Instructions

Only properly trained and qualified installers should install this appliance. The warranty may be voided due to improper installation or installation by a non-qualified installer.

It is highly recommended that all installers attend a product knowledge class.

General Instructions

Do not use substitute materials.

Use only parts certified with the appliance.

This appliance must be installed by a state qualified or licensed contractor. It is the responsibility of the person having the water heater installed to ensure the installing contractor has proper licenses and permits for installing water heaters in your location. It is highly recommended that installers attend a product knowledge class to ensure customer satisfaction and warranty coverage. Failure to comply with state and local codes pertaining to water heater installations may void the warranty.

This appliance is not to be installed outdoors.

A qualified installer or service technician should install the appliance, inspect it, and leak test it before use.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa) (13.84 in W.C.).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa) (13.84 in W.C.).

Follow the installation instructions and those in Care and Maintenance for adequate combustion and ventilation air.

The appliance should be located in an area where water leakage of the unit or connections will not result in damage to the area adjacent to the appliance or to lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow.

The flow of combustion and ventilation air shall not be obstructed.

This appliance is not suitable for use in an application such as a pool or spa heater that uses chemically treated water . (This appliance is suitable for filling large or whirlpool bath tubs with potable water.)

If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or local plumbing inspector on how to control thermal expansion.

Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

Keep the air intake location free of chemicals such as chlorine or bleach that produce fumes. These fumes can damage components and reduce the life of your appliance.

305, 505, 705 Indoor Manual

13

Image 13
Contents ANS Z21.10.3 CSA Models 305 505 705Table of Contents Model 305 505 705 SpecificationsSafety Definitions Consumer Safety InformationSafety Behavior and Practices Safety Features Features Features Available on Temperature ControllersDescription of Operation Operating InstructionsTemperature Options Without a Temperature Controller Setting the TemperatureSetting Controller to Mute Temperature RangesModel Temperature Settings Available ºF Re-setting the Maximum TemperatureMaintenance Error Code Table Error CodesCode Fault Remedy Code Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Water Heater Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceGas Piping Electrical ConnectionGeneral Instructions Pipe Sizing Procedure Example Pressure Relief Valve Water PipingFreeze Protection Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation SystemsIntake / Exhaust Guidelines Venting InstructionsCondensate Maximum Vent Length Listed and Tested Vent Products for the 305 and 505 Models Venting ProductsListed and Tested Vent Products for the 705 Model Manufacturer Product PartsFlue Terminal Clearances ANS Z21.10.3 CSA Vent Terminal Area Where Terminal is not PermitttedInside Corner Additional Clearances Vent TerminalFlue Installation for the 305 and 505 Models Air Intake Assembly Flue Installation for the 705 ModelExhaust Pipe Assembly Venting Clearances to CombustiblesVertical Terminations Horizontal with Concentric TerminationConnecting Multiple Water Heaters High Altitude InstallationsNumber of Connected Water Heaters Accessories Necessary GuidelinesConfigurations Temperature Controller InstallationLocation Cable Lengths and SizeOutlineofofControllRem ter Mounting the ControllerOperating Instructions For Your Safety Read Before OperatingPressure Drop Curve Technical DataOutlet Flow Data Replacement Temperature SettingSpace Heating Pumps505 Models DimensionsHOT Ladder DiagramWhat is covered? WarrantyWhat will be done? What is not covered? How do I get service?Limitation on implied warranties U287-084