State Industries 705 Series 200, U287-084 Recommended Piping for Basic Installation, Qty

Page 19

Recommended Piping for Basic Installation

Water Heater

Equipment List

QTY

Water Heaters

1

Plumbing Installation

1

Kit (Optional)

(3/4" Fittings Include:

2 Unions, 2 Ball Valves,

2 Drain Valves and

1 Pressure Relief Valve.)

3/4" Gas Connection

3/4" Hot Water Supply Line

For Building Fixtures

 

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

Gas Supply

3/4" Cold Water Supply Line

This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.

305, 505, 705 Indoor Manual

19

Image 19
Contents ANS Z21.10.3 CSA Models 305 505 705Table of Contents Model 305 505 705 SpecificationsSafety Definitions Consumer Safety InformationSafety Behavior and Practices Safety Features Operating Instructions Features Available on Temperature ControllersFeatures Description of OperationTemperature Options Without a Temperature Controller Setting the TemperatureRe-setting the Maximum Temperature Temperature RangesSetting Controller to Mute Model Temperature Settings Available ºFMaintenance Error Code Table Error CodesCode Fault Remedy Code Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Water Heater Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceGas Piping Electrical ConnectionGeneral Instructions Pipe Sizing Procedure Example Pressure Relief Valve Water PipingFreeze Protection Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation SystemsIntake / Exhaust Guidelines Venting InstructionsCondensate Maximum Vent Length Manufacturer Product Parts Venting ProductsListed and Tested Vent Products for the 305 and 505 Models Listed and Tested Vent Products for the 705 ModelFlue Terminal Clearances ANS Z21.10.3 CSA Vent Terminal Area Where Terminal is not PermitttedInside Corner Additional Clearances Vent TerminalFlue Installation for the 305 and 505 Models Venting Clearances to Combustibles Flue Installation for the 705 ModelAir Intake Assembly Exhaust Pipe AssemblyVertical Terminations Horizontal with Concentric TerminationGuidelines High Altitude InstallationsConnecting Multiple Water Heaters Number of Connected Water Heaters Accessories NecessaryCable Lengths and Size Temperature Controller InstallationConfigurations LocationOutlineofofControllRem ter Mounting the ControllerOperating Instructions For Your Safety Read Before OperatingPressure Drop Curve Technical DataOutlet Flow Data Pumps Temperature SettingReplacement Space Heating505 Models DimensionsHOT Ladder DiagramWhat is covered? WarrantyWhat will be done? What is not covered? How do I get service?Limitation on implied warranties U287-084