State Industries 705 Series 200, U287-084 Error Codes, Error Code Table, Code Fault Remedy

Page 9

Error Codes

This appliance has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the Display of the temperature controller. This assists with diagnosing the fault and may enable you to overcome a problem without a service call. Please identify the code displayed when inquiring about service.

Error Code Table

Code

Fault

Remedy

02

No burner operation during

Service Call

 

freeze protection mode

 

 

 

 

10

Air Supply or Exhaust

Ensure approved venting materials are being used.

 

Blockage

Check that nothing is blocking the flue inlet or exhaust.

 

 

Check all vent components for proper connections.

 

 

Ensure vent length is within limits.

 

 

Ensure condensation collar was installed correctly.

 

 

Verify dip switches are set properly.

 

 

Check fan for blockage.

 

 

 

11

No Ignition

Check that the gas is turned on at the water heater, gas meter, or cylinder.

 

 

Ensure gas type and pressure is correct.

 

 

Ensure gas line, meter, and/or regulator is sized properly.

 

 

Bleed all air from gas lines.

 

 

Verify dip switches are set properly.

 

 

Ensure appliance is properly grounded.

 

 

Disconnect all 2-Unit or Multi-Unit connections to isolate the problem.

 

 

Ensure igniter is operational.

 

 

Check igniter wiring harness for damage.

 

 

Check gas solenoid valves for open or short circuits.

 

 

Remove burner cover and ensure all burners are properly seated.

 

 

Remove burner plate and inspect burner surface for condensation or debris.

12

Flame Failure

Check that the gas is turned on at the water heater and gas meter. Check for

 

 

obstructions in the flue outlet.

 

 

Ensure gas line, meter, and/or regulator is sized properly.

 

 

Ensure gas type and pressure is correct.

 

 

Bleed all air from gas lines.

 

 

Ensure proper venting material was installed.

 

 

Ensure condensation collar was installed properly.

 

 

Ensure vent length is within limits.

 

 

Verify dip switches are set properly.

 

 

Ensure appliance is properly grounded.

 

 

Disconnect keypad.

 

 

Disconnect all 2-Unit or Multi-Unit connections to isolate the problem.

 

 

Check power supply for loose connections.

 

 

Check power supply for proper voltage and voltage drops.

 

 

Ensure flame rod wire is connected.

 

 

Check flame rod for carbon build-up.

 

 

Disconnect and reconnect all wiring harnesses on unit and PC board.

 

 

Check all components for electrical short.

 

 

Check gas solenoid valves for open or short circuits.

 

 

Remove burner plate and inspect burner surface for condensation or debris.

 

 

 

305, 505, 705 Indoor Manual

9

Image 9
Contents ANS Z21.10.3 CSA Models 305 505 705Table of Contents Model 305 505 705 SpecificationsConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features Features Features Available on Temperature ControllersDescription of Operation Operating InstructionsTemperature Options Without a Temperature Controller Setting the TemperatureSetting Controller to Mute Temperature RangesModel Temperature Settings Available ºF Re-setting the Maximum TemperatureMaintenance Error Codes Error Code TableCode Fault Remedy Code Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Water Heater Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Pressure Relief ValveFreeze Protection Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation SystemsVenting Instructions Intake / Exhaust GuidelinesCondensate Maximum Vent Length Listed and Tested Vent Products for the 305 and 505 Models Venting ProductsListed and Tested Vent Products for the 705 Model Manufacturer Product PartsFlue Terminal Clearances ANS Z21.10.3 CSA Vent Terminal Area Where Terminal is not PermitttedInside Corner Additional Clearances Vent TerminalFlue Installation for the 305 and 505 Models Air Intake Assembly Flue Installation for the 705 ModelExhaust Pipe Assembly Venting Clearances to CombustiblesVertical Terminations Horizontal with Concentric TerminationConnecting Multiple Water Heaters High Altitude InstallationsNumber of Connected Water Heaters Accessories Necessary GuidelinesConfigurations Temperature Controller InstallationLocation Cable Lengths and SizeOutlineofofControllRem ter Mounting the ControllerOperating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Replacement Temperature SettingSpace Heating Pumps505 Models DimensionsHOT Ladder DiagramWarranty What is covered?What will be done? How do I get service? What is not covered?Limitation on implied warranties U287-084