State Industries U287-084, 705 Series 200 installation manual Dimensions, Models

Page 36

Dimensions

305 and 505 Models

705 Model

AB

C

D

A

L B

C

D

 

 

K

 

 

 

K

E H

G I

E

H

 

I

 

F

J

 

F

J

G

 

 

 

 

 

 

DIM

DESCRIPTION

305

 

705

 

 

505

 

 

 

 

in (mm)

 

 

in (mm)

 

 

 

 

 

 

A

Width

14 (355.6)

 

18.5

(470)

B

Depth *

9.6 (244.5)

 

9.1 (230.5)

C

Height - Unit

22.9

(582)

 

23.6

(600)

D

Height - with brackets

25.5 (648.2)

 

25.2 (639.8)

E

Hot Water Outlet - from wall *

3.6

(91)

 

4.3 (110)

F

Hot Water Outlet - from center

4.3 (110)

 

2.4

(61)

G

Cold Water Inlet - from wall *

2.8

(70)

 

3.7

(94)

H

Cold Water Inlet - from center

1.1

(27)

 

2.0

(52)

I

Gas Connection - from wall *

4.3 (109)

 

2.2 (56.2)

J

Gas Connection - from center

3.5

(89)

 

4.3 (110)

 

From base to gas connection

1.6

(40)

 

1.6

(40)

K

From base to cold connection

2.0

(50)

 

2.0

(50)

 

From base to hot connection

1.6

(41)

 

1.6

(41)

*This is the minimum dimension from the wall. The wall bracket is adjustable to allow an additional 1.57 inches (40 mm).

36

305, 505, 705 Indoor Manual

Image 36
Contents Models 305 505 705 ANS Z21.10.3 CSATable of Contents Specifications Model 305 505 705Consumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features Features Available on Temperature Controllers FeaturesDescription of Operation Operating InstructionsSetting the Temperature Temperature Options Without a Temperature ControllerTemperature Ranges Setting Controller to MuteModel Temperature Settings Available ºF Re-setting the Maximum TemperatureMaintenance Error Codes Error Code TableCode Fault Remedy Code Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Flushing the Heat Exchanger Error Code LC or Water HeaterInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Pressure Relief ValveFreeze Protection Freeze Protection Piping Water HeaterRecommended Piping for Basic Installation QTYRecommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems For this applicationVenting Instructions Intake / Exhaust GuidelinesCondensate Maximum Vent Length Venting Products Listed and Tested Vent Products for the 305 and 505 ModelsListed and Tested Vent Products for the 705 Model Manufacturer Product PartsVent Terminal Area Where Terminal is not Permittted Flue Terminal Clearances ANS Z21.10.3 CSAAdditional Clearances Vent Terminal Inside CornerFlue Installation for the 305 and 505 Models Flue Installation for the 705 Model Air Intake AssemblyExhaust Pipe Assembly Venting Clearances to CombustiblesHorizontal with Concentric Termination Vertical TerminationsHigh Altitude Installations Connecting Multiple Water HeatersNumber of Connected Water Heaters Accessories Necessary GuidelinesTemperature Controller Installation ConfigurationsLocation Cable Lengths and SizeMounting the Controller OutlineofofControllRem terFor Your Safety Read Before Operating Operating InstructionsTechnical Data Pressure Drop CurveOutlet Flow Data Temperature Setting ReplacementSpace Heating PumpsDimensions 505 ModelsLadder Diagram HOTWarranty What is covered?What will be done? How do I get service? What is not covered?Limitation on implied warranties U287-084