State Industries 705 Series 200, U287-084 Trouble Shooting for Common Issues, Water Quality

Page 11

Trouble Shooting for Common Issues

I don’t have any hot water when I open the tap.

Make sure there is gas, water, and electricity to the water heater (power is turned on and the gas is turned on).

When I was using the hot water, the water got cold.

If you adjusted the flow from the tap to lessen it, you may have gone below the minimum flow required. This water heater requires a minimum flow rate to operate. (See the specification page for the flow rate of your model.) Decrease the temperature setting at the temperature controller or increase the water flow.

White smoke comes out of the exhaust.

During colder weather when the exhaust temperature is much hotter than the outside air, the exhaust fumes condense producing water vapor.

When I open a hot tap, I do not immediately get hot water.

Hot water must travel through your plumbing from the water heater to the faucet. The time period for hot water to reach your fixture is determined by the amount of water in the plumbing system between the water heater and the fixture, water pressure, and the flow rate of the fixture.

After I turn off the hot water tap, the fan on the water heater continues to run.

The fan is designed to continue running for a short time after the flow of water stops. This is to ensure constant water temperatures during rapid starting and stopping, as well as exhausting any residual gas flue products from the unit.

Accessing Operating Information

To display the most recent error codes press and hold the “On/Off” button for 2 seconds. While holding the “On/ Off” button press the ▲ button. The last 9 error codes will flash one after the other. To exit this mode press the “On/Off” and ▲ button as before.

To display the water flow through the water heater press and hold the ▲ button for 2 seconds and without releasing the ▲ button press the “On/Off” button.

To display the outlet water temperature press and hold the ▼ button for 2 seconds and without releasing the ▼ button press the “On/Off” button.

Water Quality

Consideration of care for your water heater should include evaluation of water quality. If the water quality exceeds the target levels provided in the table, you may want to treat or condition the water.

*Source: Part 143 National Secondary Drinking Water Regulations

 

Maximum Level

 

 

Total Hardness

Up to 200 mg / L

 

 

Aluminum *

Up to 0.2 mg / L

 

 

Chlorides *

Up to 250 mg / L

 

 

Copper *

Up to 1.0 mg / L

 

 

Iron *

Up to 0.3 mg / L

 

 

Manganese *

Up to 0.05 mg / L

 

 

pH *

6.5 to 8.5

 

 

TDS (Total Dissolved

Up to 500 mg / L

Solids) *

 

Zinc *

Up to 5 mg / L

 

 

305, 505, 705 Indoor Manual

11

Image 11
Contents ANS Z21.10.3 CSA Models 305 505 705Table of Contents Model 305 505 705 SpecificationsSafety Behavior and Practices Safety Features Consumer Safety InformationSafety Definitions Operating Instructions Features Available on Temperature ControllersFeatures Description of OperationTemperature Options Without a Temperature Controller Setting the TemperatureRe-setting the Maximum Temperature Temperature RangesSetting Controller to Mute Model Temperature Settings Available ºFMaintenance Code Fault Remedy Error CodesError Code Table Code Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Water Heater Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceGeneral Instructions Electrical ConnectionGas Piping Pipe Sizing Procedure Example Freeze Protection Water PipingPressure Relief Valve Water Heater Freeze Protection PipingQTY Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation SystemsCondensate Venting InstructionsIntake / Exhaust Guidelines Maximum Vent Length Manufacturer Product Parts Venting ProductsListed and Tested Vent Products for the 305 and 505 Models Listed and Tested Vent Products for the 705 ModelFlue Terminal Clearances ANS Z21.10.3 CSA Vent Terminal Area Where Terminal is not PermitttedInside Corner Additional Clearances Vent TerminalFlue Installation for the 305 and 505 Models Venting Clearances to Combustibles Flue Installation for the 705 ModelAir Intake Assembly Exhaust Pipe AssemblyVertical Terminations Horizontal with Concentric TerminationGuidelines High Altitude InstallationsConnecting Multiple Water Heaters Number of Connected Water Heaters Accessories NecessaryCable Lengths and Size Temperature Controller InstallationConfigurations LocationOutlineofofControllRem ter Mounting the ControllerOperating Instructions For Your Safety Read Before OperatingOutlet Flow Data Technical DataPressure Drop Curve Pumps Temperature SettingReplacement Space Heating505 Models DimensionsHOT Ladder DiagramWhat will be done? WarrantyWhat is covered? Limitation on implied warranties How do I get service?What is not covered? U287-084