Additional Clearances - Vent Terminal
Local codes supersede these clearances.
•Avoid termination locations near a dryer vent.
•Avoid termination locations near commercial cooking exhaust.
 Vent terminal (represents concentric vent terminal for the water heater)
 Vent terminal (represents concentric vent terminal for the water heater)
 12"
 12"
(0.30 m ) to an inside corner
(0.91 m) to ventilated or unventilated soffit
36" or eve vent; or to a deck or porch
VV  12"
 12"
V
(1.52 m) vertically 60" between water heater
terminals
V
(0.30 m) between water heater terminals at same level
INSIDE
CORNER
24" (0.61 m) to wall or parapet
V
(1.52 m) between water heater terminals at different levels
V
60"
V
| 12" | 
 | (0.30 m) between water | |
| V | V | heater terminals at same | |
| level | |||
| 
 | 
 | 
| 26 | 305, 505, 705 Indoor Manual |