State Industries U287-084 Recommended Piping for Circulation Systems, For this application

Page 20

Recommended Piping for Circulation Systems

NOTE:

For residential and commercial applications, this piping arrange- ment maintains full warranty.

Water Heater

For this application:

Equipment List

QTY

Water Heaters

1

Plumbing Installation

1

Kit (Optional)

(3/4" Fittings Include:

2 Unions, 2 Ball Valves,

2 Drain Valves and

1 Pressure Relief Valve.)

Pump should be controlled by an Aqua- stat, Timer or Combination Aquastat and Timer.

Pump to be sized to maintain circulation loop temperature.

The pump should be sized to overcome the pressure loss through the tank water heater, and supply and return plumbing.

Pump to be of bronze or stainless construction.

3/4" Gas Connection

Gas Supply

Minimum 3/4" Cold Water Supply Line

IMPORTANT: Connect the building return line to the hot water supply line as close as possible to the water heater.

Tank Water Heater to be Sized for Heat Loss of Circulation Loop.

Electric Water

Heater

Building Supply

Building

Fixtures

Expansion Tank

 

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.

20

305, 505, 705 Indoor Manual

Image 20
Contents Models 305 505 705 ANS Z21.10.3 CSATable of Contents Specifications Model 305 505 705Safety Behavior and Practices Safety Features Consumer Safety InformationSafety Definitions Features Available on Temperature Controllers FeaturesDescription of Operation Operating InstructionsSetting the Temperature Temperature Options Without a Temperature ControllerTemperature Ranges Setting Controller to MuteModel Temperature Settings Available ºF Re-setting the Maximum TemperatureMaintenance Code Fault Remedy Error CodesError Code Table Code Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Flushing the Heat Exchanger Error Code LC or Water HeaterInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGeneral Instructions Electrical ConnectionGas Piping Pipe Sizing Procedure Example Freeze Protection Water PipingPressure Relief Valve Freeze Protection Piping Water HeaterRecommended Piping for Basic Installation QTYRecommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems For this applicationCondensate Venting InstructionsIntake / Exhaust Guidelines Maximum Vent Length Venting Products Listed and Tested Vent Products for the 305 and 505 ModelsListed and Tested Vent Products for the 705 Model Manufacturer Product PartsVent Terminal Area Where Terminal is not Permittted Flue Terminal Clearances ANS Z21.10.3 CSAAdditional Clearances Vent Terminal Inside CornerFlue Installation for the 305 and 505 Models Flue Installation for the 705 Model Air Intake AssemblyExhaust Pipe Assembly Venting Clearances to CombustiblesHorizontal with Concentric Termination Vertical TerminationsHigh Altitude Installations Connecting Multiple Water HeatersNumber of Connected Water Heaters Accessories Necessary GuidelinesTemperature Controller Installation ConfigurationsLocation Cable Lengths and SizeMounting the Controller OutlineofofControllRem terFor Your Safety Read Before Operating Operating InstructionsOutlet Flow Data Technical DataPressure Drop Curve Temperature Setting ReplacementSpace Heating PumpsDimensions 505 ModelsLadder Diagram HOTWhat will be done? WarrantyWhat is covered? Limitation on implied warranties How do I get service?What is not covered? U287-084