State Industries SBL95 199NE, SBL85 275NE(A) Installation considerations, Rough In Dimensions

Page 8

Installation considerations

Rough In Dimensions

I

1 1/2"

NPT

G

B

J FRONT VIEW

TOP OUTLET

1 1/2" NPT

A C

D H

E

TOP INLET 1 1/2" NPT

F

K

M

L

TOP VIEW

BACK VIEW

Figure 6.

Table 1. Rough-In-Dimensions

Model Dim.

SBL95 199NE

SBL85 275NE(A)

SBL85 390NE(A)

inches

cm

inches

cm

inches

cm

 

A

76

193.0

76

193.0

76

193.0

B

11 3/4

29.8

11 3/4

29.8

11 3/4

29.8

C

78 1/4

198.8

78 1/4

198.8

78 1/4

198.8

D

65 3/4

167.0

65 3/4

167.0

65 3/4

167.0

E

25 3/4

65.4

25 3/4

65.4

25 3/4

65.4

F

21

53.3

21

53.3

21

53.3

G

3/4 NPT

 

3/4 NPT

 

3/4 NPT

 

H

66 1/4

168.3

66 1/4

168.3

66 1/4

168.3

I

6

15.2

6

15.2

6

15.2

J

27 3/4

70.5

27 3/4

70.5

27 3/4

70.5

K

1 1/2 NPT

 

1 1/2 NPT

 

1 1/2 NPT

 

L

1 1/2 NPT

 

1 1/2 NPT

 

1 1/2 NPT

 

M

41

104

41

104

41

104

Approx. Shipping Weight STD

790 lbs.

358 Kg.

850 lbs.

386 Kg.

850 lbs.

386 Kg.

Approx. Shipping Weight ASME

-

-

900 lbs.

408 Kg.

900 lbs.

408 Kg.

Table 2. Recovery Capacities, based on 82% efficiency

 

Input

Input

U.S.

 

 

 

 

 

U. S. Gallons/Hr. and Liters/Hr. at TEMPERATURE RISE INDICATED

 

 

 

 

 

BTUH

KW

Gal.

Liters

Eff. %

Deg. F

36

40

50

54

60

70

72

80

90

100

108

110

120

126

130

140

 

Deg. C

20

22

28

30

33

39

40

44

50

56

60

61

67

70

72

78

 

 

 

 

 

 

SBL95 199NE

199000

 

93

 

82

GPH

545

491

393

364

327

280

273

245

218

196

182

178

164

156

151

140

 

58

 

352

 

LPH

2064

1858

1486

1376

1239

1062

1032

929

826

743

688

676

619

590

572

531

 

 

 

 

SBL85 275NE(A)

275000

 

85

 

82

GPH

754

678

543

502

452

388

377

339

301

271

251

247

226

215

209

194

 

81

 

322

 

LPH

2853

2567

2054

1902

1712

1467

1426

1284

1141

1027

951

934

856

815

790

734

 

 

 

 

SBL85 390NE(A)

390000

 

85

 

82

GPH

1069

962

769

712

641

550

534

481

427

385

356

350

321

305

296

275

 

114

 

322

 

LPH

4046

3641

2913

2697

2427

2081

2023

1820

1618

1456

1349

1324

1214

1156

1120

1040

 

 

 

 

Table 3. Gas and Electrical Characteristics

Model

Gas Type

Gas Supply Pressure

Volts / Hz

Amperes

Minimum

Maximum

 

 

 

 

All Models

Natural

3.5" W.C. (0.87 kPa)

14" W.C. (3.48 kPa)

120/60

<5

8

Image 8
Contents Commercial gas water heaters SBL95 199NE SBL85 275NEA SBL85 390NEA Ultra Low NOx SeriesTable Of Contents Safe Installation, Use and Service ApprovalsFire and Explosion Hazard General Safety InformationFire or Explosion Hazard Hydrogen Gas Flammable PrecautionsGrounding Instructions Qualified Installer or Service Agency IntroductionAbbreviations Used QualificationsFeatures and Components Hydrocannon self-cleaning systemBlower/Burner Assembly High Limit Switch ControlsInstallation considerations Rough In DimensionsRough-In-Dimensions Recovery Capacities, based on 82% efficiencyLocating the Water Heater ClearancesNSF Leg Kit Insulation BlanketHard Water Circulation PumpsHigh Altitude Installations Breathing Hazard Carbon Monoxide GasInstallation Requirements Temperature-Pressure Relief Valve Dishwashing MachinesClosed Water Systems Thermal ExpansionWater Damage Hazard Combustible Material StorageContaminated Air Valve Discharge Pipe RequirementsAir Requirements Unconfined SpaceConfined Space VentingMultiple Heater Manifold Outdoor Air Through One Opening Fresh Air Openings for Confined SpacesOutdoor Air Through Two Openings Outdoor Air Through Two Horizontal DuctsOutdoor Air Through Two Vertical Ducts Air From Other Indoor SpacesMultiple Gas Fired Tank-Type Heaters Technical Data VentingType B GAS Vent Model SBL85 275NEA Valve Discharge Pipe Water heater installationWater Line Connections Installation Diagrams Top Inlet/Outlet Usage Heater Wiring Gas Line Leak Testing Gas PipingPurging Gas Meter Size Natural Gases OnlyInitial Start Up Start upPrior to Start Up Water Temperature Adjustment Multiple Appliance InstallationsChecking Venting Checking the InputSequence of Operation Lighting & Operating LabelSequence of Operation Flow Chart YESMaintenance Temperature-Pressure Relief Valve TestVenting System Intake Air ScreenDraining and Flushing Deliming SolventsTo Drain the Water Heater Storage Tank To Flush the Water Heater Storage TankChemical Hazard Tank Cleanout ProcedureDeliming Using Flo-Jug Method Electrical Servicing System DiagnosticsIgnition Control System High Water Temperature Shut OFF System For Your InformationStart Up Conditions Operational ConditionsComplaint Cause Remedy User TroubleshootingQualified Service Agency Diagrams Water PipingTemperature & Pressure Temperature & Pressure Relief Valve Circulating Pump Multi Flue 2 Units Multi Flue 2 Units with Vertical Storage Tank Multi Flue 2 Units with Vertical Storage Tank Return from Multi Flue 2 Units TWO Temperature Multi Flue 2 Units with Booster TWO Temperature MULTI-FLUE 3 Units MULTI-FLUE 3 Units with Vertical Storage Tank MULTI-FLUE 3 Units with Horizontal Storage Tank Multi Flue Flue 4 Units MULTI-FLUE 4 Units with Vertical Storage Tank MULTI-FLUE 4 Units with Horizontal Storage Tank Model Dimension a Page Limited Warranty ALL Other Parts