Current Fault

Description/Action

 

 

Display

 

 

 

Select Current Fault from the Main Menu and press the

 

 

 

 

 

 

Operational Button under "SELECT" to enter this menu. This

 

 

 

 

 

 

menu contains non adjustable operational information. Use the

 

 

Blocked Exhaust

 

Up & Down Buttons to navigate the menu.

 

 

 

This menu contains the current Fault or Alert error message.

 

 

Fault occurred 2 mins ago

 

 

 

 

The exhaust is blocked or

 

 

 

The time the Fault or Alert message occurred appears directly

 

 

 

 

 

restricted. Ensure

 

 

 

 

 

 

 

below. A brief description of what causes the particular Fault or

 

 

 

 

 

condensate hose is draining.

 

 

Alert condition appears below that. Pressing the Operational

 

 

 

 

 

 

 

 

 

Button under "ADVANCED" will give more detailed service

 

Call a service professional:

 

 

information and a list of possible causes for the Fault or Alert

 

 

 

 

Your Company Name Here

 

 

condition. See Fault And Alert Messages on page 48 for more

 

 

 

 

(press [DOWN] for more....)

 

 

 

 

 

detailed information and diagnostic procedures.

 

 

 

 

 

 

 

CHANGE

BACK

ADVANCED

 

If there is no Fault or Alert condition active this menu will not

 

 

 

 

 

 

 

 

contain any information, "(none)" will be shown next to Current

 

 

 

 

 

 

Fault in the Main menu.

 

 

 

 

 

 

Fault History

 

 

 

 

 

 

Description/Action

 

Display

 

Select Fault History from the Main Menu and press the

 

Fault History

 

Operational Button under "SELECT" to enter this menu. This

 

 

1:

Blocked Air Intake (A7)

menu contains non adjustable operational information. Use the

Up & Down Buttons to navigate the menu.

 

 

51 mins ago

This menu contains a list of the last nine (9) Fault and Alert

2:

Blocked Exhaust (A8)

messages with a time stamp. The newest event will replace the

 

 

54 mins ago

oldest.

3:

Low Gas Pressure (A6)

Press the Operational Button under "VIEW" to view details for

 

 

57 mins ago

each Fault or Alert message stored.

4:

Blower Prover Failure (AC)

 

VIEW

BACK

HELP

Fault Occurrence

 

 

 

Description/Action

 

Display

 

Select Fault Occurrence from the Main Menu and press the

Fault Occurrence

Operational Button under "SELECT" to enter this menu. This

Ignition Failure

 

10

menu contains non adjustable operational information. Use the

 

Up & Down Buttons to navigate the menu.

ECO

 

0

This menu contains a running total of how many times each

Low Gas Pressure

10

Fault condition has occurred since the water heater was first

Blocked Intake Air

0

installed.

Blocked Exhaust

0

Note: Historical data is stored in the CCB's memory. If this CCB

Thermostat Input 4

0

is replaced during servicing the historical data on the CCB being

Blower Prover

 

3

replaced will be lost. The data stored in the new circuit board will

 

BACK

HELP

no longer reflect the entire history of the water heater.

 

Restore Factory Defaults

 

 

 

Description/Action

 

Display

 

Select Restore Factory Defaults from the Main Menu and press

Restore Factory Defaults

the Operational Button under "SELECT" to enter this menu.

To restore the adjustable user settings to their factory default

 

Are you sure you want to

settings press the Operational Button underneath “YES.” The

 

display will show text confirming the factory default settings

 

restore the system to factory

have been restored.

 

defaults?

Press the Operational Button underneath “BACK” to exit the

 

 

Restore Factory Defaults menu.

 

 

 

YES

NO

48

Image 48
Contents Commercial gas water heaters Table Of Contents Safe Installation, Use and Service ANSI/NSF-5Optional General Safety Information PrecautionsHydrogen Gas Flammable Overheated water can cause water tank explosionInstalling, using or servicing Water heater Fire and Explosion HazardPreparing For The Installation IntroductionAbbreviations Used QualificationsFeatures And Components Basic OperationWater Heater’s 120 VAC on/off switch Top ViewTop View Components Side Views Installation Considerations Rough In DimensionsRecovery Capacities Gas Line Connection SizeService Clearance Locating The Water HeaterClearance To Combustible Materials Intake Air and Vent Pipe ClearancesExtended Vent Terminations Optional Concentric TerminationsHard Water Circulation PumpsInstallation Requirements Power SupplyGas Pressure Requirements Supply Gas LineMixing Valves Dishwashing MachinesClosed Water Systems Thermal ExpansionTemperature-Pressure Relief Valve Valve Discharge Pipe RequirementsCondensate Drain Combustible Material StorageContaminated Air Condensate Drain Water TrapAir Requirements Unconfined SpaceConfined Space Fresh Air Openings For Confined Spaces Outdoor Air Through Two OpeningsOutdoor Air Through One Opening Outdoor Air Through Two Horizontal DuctsPage Commonwealth of Massachusetts InspectionVenting Installation General Venting InformationGeneral Venting Instructions Venting Requirements Venting Installation Sequence Power Vent InstallationDirect Vent Installation Vertical Termination Installation 3 ReducerVertical Termination Direct Vent Sidewall Termination Installation Concentric Termination Installation Inch Concentric Termination Flat Roof ClearanceInch Concentric Termination Installation Inch Concentric Termination KITInch Concentric Termination Sidewall Installation TWO Concentric Terminations Three Concentric TerminationsFour Concentric Terminations Eight Concentric TerminationsMultiple Concentric Termination Arrangements Two Concentric TerminationsEight Concentric Terminations Power Vent Horizontal Venting ArrangementsDirect Vent Horizontal Direct Vent Vertical Vent Horizontal Intake Direct Vent Horizontal Vent Vertical IntakeDirect Vent Horizontal Concentric Termination Clearances Sidewall Power Vent Power VentTermination Clearances Sidewall Direct Vent Direct VentWater Heater Installation Condensate Drain InstallationInstallation Notes Installation InstructionsSupply Gas Line Installation Gas Line SizingSupply Gas Line Sizing U. S. Units Supply Gas Line Sizing Metric UnitsSupply Gas Regulator Installation Gas Line Leak TestingGas Line Connection Electrical Wiring Power Supply ConnectionsEnable/Disable Circuit Connecting An External Supervisory ControlWater Piping Diagrams Water Line ConnectionsValve Discharge Pipe Thermometers not SuppliedTemperature Regulation High Temperature Limit Control ECOHigh Temperature Applications Thermostat ControlControl System Operation OverviewControl System Navigation User Input ButtonsStatus Icons Icon DescriptionOperating States State DescriptionControl System Menus Menu DescriptionUser Settings & Control System Menus Update CancelBack Help Description/Action DisplayChange Back Help Display Settings Description/Action Heater Information Description/Action DisplayBack Advanced View Back HelpECO YESUpdate Service Contact InformationSelect Back Help NameStart Up Prior to Start upInitial Start Up Supply Gas Pressure Adjustment Multiple Appliance InstallationsManifold Gas Pressure Adjustment High Altitude Installations Checking The Firing Rate1050 = 300,000 Btu/hr 87.9 kW To Turn Off GasLighting The Water Heater Lighting & Operation LabelHoneywell Troubleshooting Installation ChecklistSequence Of Operation Sequence Of Operation Flow Chart Closed by control system Fault Msg is displayedPre-Purge cycle Water is heated to VAC Gas ValveOperational Problems Installation ErrorsRough Starting, Rough Operation Momentary IgnitionFault And Alert Conditions Fault And Alert Messages Possible Causes Check/Repair Displayed Fault/Alert MessageBlower Prover Failure No Anode VoltageMaintenance Maintenance ScheduleGeneral Draining And FlushingFilling The Water Heater Sediment RemovalLime Scale Removal Powered Anode Rods Drain Valve and Access PanelsTemperature-Pressure Relief Valve Test Vent SystemDiagrams CCB Central Control Board LayoutSUF 130 300 Wiring Diagram User Interface ModulSUF 130 400, 500 Wiring Diagram UserCirculation Pump Wiring Diagrams Water Piping Diagrams Temperature & Pressure Tank Temperature ALT. Cold Water State Storage Tank Water Piping Diagrams Line Temperature Control HOT Water Outlet Pipe T&P to Open Drain Finished Floor Limited Warranty