Venting
Outside air flex pipe goes here.
Flex pipe part#
Inlet Cover part#
Direct Vent Wall Passthrough Kit
(part
Vent Configurations:
Per national building codes, consideration must be given to combustion air supply to all combustion appli- ances. Failure to supply adequate combustion air for all appliance demands, may lead to
When the appliance is
When the appliance is roof vented: The air intake is best located on the exterior wall oriented towards the prevailing wind direction during the heating season.
The outside air connection will supply the demands of the pellet appliance, but consideration must be given to the total house demand. House demand may con- sume some air needed for the stove, especially during a power failure. It may be necessary to add additional ventilation to the space in which the pellet appliance is located. Consult with your local HVAC professional to determine the ventilation demands for your house.
To install outside air use 2 3/8" I.D.
You may choose to use the optional Direct Vent Wall Passthrough Kit (part
To reduce probability of reverse drafting during
•Installing the pellet vent with a minimum vertical run of five feet, preferably terminating above the roof line.
•Installing the outside air intake at least four feet below the vent termination.
To prevent soot damage to exterior walls of the house and to prevent
•Maintain specified clearances to windows, doors, and air inlets, including air conditioners.
•Vents should not be placed below ventilated soffits. Run the vent above the roof.
•Avoid venting into alcove locations.
•Vents should not terminate under overhangs, decks or onto covered porches.
•Maintain minimum clearance of 12 inches from the vent termination to the exterior wall. If you see
deposits developing on the wall, you may need to extend this distance to accommodate your installation conditions.
Hearth & Home Technologies assumes no responsibility for, nor does the warranty extend to, smoke damage caused by reverse drafting of pellet appliances under
10P61A Pellet Stove