Low Draft Voltage Adjustment

C o m b u s t i o n

Motor Speed

Control

Low draft only set point.

The small straight screwdriver slot is plastic; therefore, the unit can be adjusted while in operation.

Fig.22

Low Draft Voltage Adjustment

These units are pre-tested at the factory with exactly 120 Volts A.C., 60 Hz. They are checked and adjusted for firebox tightness, gasket leakage, motor operation and igniter operation. The P61A is then factory set at a mid-point adjustment and in most cases will not need any adjustments. NOTE: The factory low draft setting may not be correct for the unit's permanent installation conditions.

The control board on the P61A is equipped with a low draft adjustment port. Located on the control face just to the right of the igniter light. This voltage adjustment is provided to allow the unit to be adjusted for the household voltage where the unit is going to be in permanent operation. NOTE: The line voltage varies from area to area and often home to home.

The low draft voltage should be adjusted to achieve the most efficient burn on low burn or "maintenance". This voltage adjustment allows the installer to change the low voltage set point approximately 10 volts. This adjustment should be done by the installer during set up because a draft meter reading is required to insure proper set up.

If the unit is not adjusted properly, it does not cause a safety concern. If the unit is adjusted too high, only efficiency is lost. If the unit is adjusted too low, the low draft pressure switch will not allow the feed motor or the igniter to operate.

Draft Meter bolt hole location

T h e d r a f t test hole is under the left rear corner of the firebox.

Fig. 23

A simple draft test should be performed after completing the flue pipe installation. To record the results for future reference:

1.Plug unit into a 120VAC, 60 HZ outlet.

2.Close the hopper lid, front view door, and the ash pan. Neither pellets or a fire are required for this test.

3.With the mode selector in the "OFF" position, turn the feed adjuster to "TEST".

4.Record the high draft_____in W.C. (Normal is -.50 to -.60) The control will be on the High Draft for a total of 1 minute.

5.After the minute, the combustion motor will go down to low draft and the distribution blower will go on high. Allow approximately 15 seconds to pass for the combustion motor to slow before checking the low draft.

6.If the low draft is between -.35 and -.45, record the reading _____ in W.C. If the reading is higher, slowly turn the set screw counter-clockwise until the draft lowers. If the reading is lower, very slowly turn the set screw clockwise until the draft increases.

NOTE: In some cases, the draft may not go as low as -.35 to -.45 even with the set screw completely counter-clockwise. Ideally, you should just set it as low as possible.

P61A Pellet Stove 21

Image 21
Contents Safety Notice Installation & Operating ManualPage Label Table of Contents Important Notes Room Sensor Installation Assembly and InstallationInstallation InstallingMobile Home Installation With outside air installed, 6 feet VentingAddition, the following must be observed PL Vent, Must Be Used Negative Pressure, Shut-down, and Power FailureOutside Air VentingVent Configurations #2 Preferred method #1 Preferred method#4 Installing into an existing chimney #5 Installing into an existingFireplace chimney #7 Installing into an existing chimney #6 Installing into an existing fireplace chimney#8 Installing through the ceiling Minimum flue vent configurationAutomatic Ignition ESP Control Status light error messagesAutomatic IGNITION/OPERATION Room Temperature ModeStove Temperature Mode Feed Adjuster KnobShut Down Procedure Turn Mode Selector to OFF Igniter Switch to Auto up positionTurn Feed Adjuster to #4.4 Automatic Start UPManual IGNITION/Operation Igniter Switch to Manual down position Manual Start UPFill hopper with pellets and remove ashes as required.1 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentMaintenance Glass ReplacementMinimizing Creosote Cleaning Scraping the burn potRemoving Ashes Not equipped with a fine dust filter may clog Disperse fly ash and soot into the roomSoot and Fly Ash Burn Pot Cleaning and Maintenance Maintenance Burn PotSafety Features Maintenance Cleaning the Feeder BodyCleaning Burn Pot Trouble-ShootingFire has Gone OUT- Check for status light Curing PaintFuel and Fuel Storage Fuel SpecificationsOperation in Stove Temp mode Operation in Room Temp modeChanges to Maintenance Schedule 30 P61A Pellet Stove Hopper Extension -Part#1-00-08636 Side Heat ShieldsDirect Vent Wall Passthrough Kit Decorative Slate OptionsSpecifications Wiring DiagramHearth & Home Technologies Inc Limited Lifetime WarrantyThis warranty is void if Warranty ConditionsPart number list on following Service PartsStocked at depot #2 Pre Serial number 008085092 Feeder Assembly#3 Post Serial number 008085803 Feeder Assembly At depotStocked Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper