Harman Stove Company P61A manual Important Notes

Page 5

IMPORTANT NOTES

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

SPECIAL NOTE:

Due to fly ash buildup, it is strongly recommended that you have your stove professionally cleaned and serviced annually. This includes all parts of the stove, and the entire venting system.

CAUTION

Always be sure there is no unburned fuel in the ash pan prior to lighting a fire. This will cause smoke and soot and other unwanted results.

WARNING

M o b i l e / M a n u fa c t u r e d H o m e S ta n d a r d s D o N o t A l l o w Installation In Rooms Designated For Sleeping.

CAUTION

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.

Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.

CAUTION

Keep combustible materials (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building.

CAUTION

DO NOT USE MAKESHIFT COMPONENTS OR OTHER COMPROMISES WHEN INSTALLING THIS APPLIANCE.

Installation and repair of this Harman stove should be done by a qualified service person. We recom- mend that the stove be inspected before use and at least annually by a qualified service person. Periodic cleaning is required throughout the heating season and at the end of each winter for the stove to work efficiently. See cleaning instruc- tions on page 22.

CAUTION

A CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF SPACE, CLOSET OR OTHER CONCEALED SPACE, A FLOOR, OR A CEILING.

CAUTION

DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.

P61A Pellet Stove 5

Image 5
Contents Safety Notice Installation & Operating ManualPage Label Table of Contents Important Notes Room Sensor Installation Assembly and InstallationMobile Home Installation InstallationInstalling Addition, the following must be observed With outside air installed, 6 feetVenting PL Vent, Must Be Used Negative Pressure, Shut-down, and Power FailureOutside Air VentingVent Configurations #2 Preferred method #1 Preferred methodFireplace chimney #4 Installing into an existing chimney#5 Installing into an existing #7 Installing into an existing chimney #6 Installing into an existing fireplace chimney#8 Installing through the ceiling Minimum flue vent configurationAutomatic Ignition ESP Control Status light error messagesAutomatic IGNITION/OPERATION Room Temperature ModeShut Down Procedure Stove Temperature ModeFeed Adjuster Knob Turn Mode Selector to OFF Igniter Switch to Auto up positionTurn Feed Adjuster to #4.4 Automatic Start UPManual IGNITION/Operation Fill hopper with pellets and remove ashes as required.1 Igniter Switch to Manual down positionManual Start UP Low Draft Voltage Adjustment Low Draft Voltage AdjustmentMinimizing Creosote MaintenanceGlass Replacement Removing Ashes CleaningScraping the burn pot Soot and Fly Ash Not equipped with a fine dust filter may clogDisperse fly ash and soot into the room Burn Pot Cleaning and Maintenance Maintenance Burn PotSafety Features Maintenance Cleaning the Feeder BodyCleaning Burn Pot Trouble-ShootingFire has Gone OUT- Check for status light Curing PaintFuel and Fuel Storage Fuel SpecificationsChanges to Maintenance Schedule Operation in Stove Temp modeOperation in Room Temp mode 30 P61A Pellet Stove Hopper Extension -Part#1-00-08636 Side Heat ShieldsDirect Vent Wall Passthrough Kit Decorative Slate OptionsSpecifications Wiring DiagramHearth & Home Technologies Inc Limited Lifetime WarrantyThis warranty is void if Warranty ConditionsPart number list on following Service PartsStocked at depot #2 Pre Serial number 008085092 Feeder AssemblyStocked #3 Post Serial number 008085803 Feeder AssemblyAt depot Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper