Harman Stove Company P61A manual Manual Start UP, Igniter Switch to Manual down position

Page 20

Manual START UP

Fig. 20

Fig. 19

See Hint #7.

1"

Fig. 21

Helpful Hints

1.Fines are small pieces of broken pellets (sawdust). Fines do not flow easily and often build up on the hopper funnel bottom angles. You can push these fines into the feeder opening and then fill the hopper with pellets. As the system works, they will be burned. Or you can clean them out before filling the hopper. As the system works, they will be burned.

2.The "TEST" cycle will operate the feeder motor for exactly one minute. Turning to "TEST" again and again may charge too much fuel into the burn pot causing excessive smoke on start-up.

3.The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open.

4.Adjust Feed Rate. If this is your first fire or you are trying different pellets, set the feed adjuster to #4, Fig. 19. This is a conservative number and will probably need to be increased. After you know a feed rate setting that works well, use that setting. Remember, if your feed rate is too high you may waste fuel.

5.This is usually a weekly maintenance procedure. Cleaning the burn pot with the scraper with a small amount of new fuel in the bottom is not a problem. First, scrape the ashes off the front of the burn pot into the ash pan. Then, scrape the top surface of the burn pot downward into the base of the burn pot. When the stove is ignited these scrapings will be pushed out by the feeder and burned.

6.The ash pan can hold the ashes from approximately 1 ton of premium fuel. This means the ashes will only need to be emptied a few times each year.

7.Setting the feed adjuster # for maximum burn: With the unit burning in "AUTO", turn to "Stove Mode" and put the fan on "H". Set the Temperature Dial to #7. Allow the unit to burn for about 30 minutes and check ash on front of burn pot. Fig. 21. If the ash line is larger than 1", turn the feed adjuster from #3 to #4. Allow another

30minutes of burn time and check again. If , at #6 setting, a 1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only a maximum burn rate and at most normal settings the ash bed will be larger.

Starting First Fire

Igniter Switch to "MANUAL" (down position)

Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit.

Notice: Be sure there is no unburned fuel or other combustibles in the ash pan prior to lighting.

1.Turn FEED ADJUSTER to desired feed rate. No. 4 is good for most pellets.4

2.Turn the Mode Selector to “OFF” and then to the desired mode. This will reset con- trol and start the combustion motor.

3.Turn the Temperature Dial to the desired setting.

4.Clean burn pot with scraper if necessary.5

5.Fill burn pot with pellets, only level with front edge. (Do Not Over Fill).

6.Add starting gel on top of the pellets. Stir gel into pellets for fast lighting.

7.Light starting gel with a match, and close the door. Operation will begin when the fire reaches the proper temperature.3

8.Fill hopper with pellets and remove ashes as required.1, 6

KEEP THE APPLIANCE DOORS AND HOPPER LID CLOSED DURING OPERATION.

Warning

"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP " A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE".

Warning

ONly use wood pellet fuel. Do not burn garbage in stove.

20P61A Pellet Stove

Image 20
Contents Installation & Operating Manual Safety NoticePage Label Table of Contents Important Notes Assembly and Installation Room Sensor InstallationMobile Home Installation InstallationInstalling Addition, the following must be observed With outside air installed, 6 feetVenting Negative Pressure, Shut-down, and Power Failure PL Vent, Must Be UsedOutside Air VentingVent Configurations #1 Preferred method #2 Preferred methodFireplace chimney #4 Installing into an existing chimney#5 Installing into an existing #6 Installing into an existing fireplace chimney #7 Installing into an existing chimneyMinimum flue vent configuration #8 Installing through the ceilingStatus light error messages Automatic Ignition ESP ControlRoom Temperature Mode Automatic IGNITION/OPERATIONShut Down Procedure Stove Temperature ModeFeed Adjuster Knob Igniter Switch to Auto up position Turn Mode Selector to OFFTurn Feed Adjuster to #4.4 Automatic Start UPManual IGNITION/Operation Fill hopper with pellets and remove ashes as required.1 Igniter Switch to Manual down positionManual Start UP Low Draft Voltage Adjustment Low Draft Voltage AdjustmentMinimizing Creosote MaintenanceGlass Replacement Removing Ashes CleaningScraping the burn pot Soot and Fly Ash Not equipped with a fine dust filter may clogDisperse fly ash and soot into the room Maintenance Burn Pot Burn Pot Cleaning and MaintenanceMaintenance Cleaning the Feeder Body Safety FeaturesTrouble-Shooting Cleaning Burn PotFire has Gone OUT- Check for status light Curing PaintFuel Specifications Fuel and Fuel StorageChanges to Maintenance Schedule Operation in Stove Temp modeOperation in Room Temp mode 30 P61A Pellet Stove Side Heat Shields Hopper Extension -Part#1-00-08636Direct Vent Wall Passthrough Kit Decorative Slate OptionsWiring Diagram SpecificationsLimited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService Parts Part number list on following#2 Pre Serial number 008085092 Feeder Assembly Stocked at depotStocked #3 Post Serial number 008085803 Feeder AssemblyAt depot Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper