Harman Stove Company P61A manual Automatic Start UP, Igniter Switch to Auto up position

Page 18

Automatic START UP

Fig. 17

Flame Guide

See Hint #7.

 

1"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 18

Helpful Hints

1.Fines are small pieces of broken pellets (sawdust). Fines do not flow easily and often build up on the hopper funnel bottom angles. You can push these fines into the feeder opening and then fill the hopper with pellets. As the system works, they will be burned. Or you can clean them out before filling the hopper.

2.The "TEST" cycle will operate the feeder motor for exactly one minute. Turning to "TEST" again and again may charge too much fuel into the burn pot causing excessive smoke on start-up.

3.The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open.

4.Adjust Feed Rate. If this is your first fire or you are trying different pellets, set the feed adjuster to #4, Fig. 17. This is a conservative number and will probably need to be increased. After you know a feed rate setting that works well, use that setting. Remember, if your feed rate is too high you may waste fuel.

5.This is usually a weekly maintenance procedure. Cleaning the burn pot with the scraper with a small amount of new fuel in the bottom is not a problem. First, scrape the ashes off the front of the burn pot into the ash pan. Then, scrape the top surface of the burn pot downward into the base of the burn pot. When the stove is ignited these scrapings will be pushed out by the feeder and burned.

6.The ash pan can hold the ashes from approximately 1 ton of premium fuel. This means the ashes will only need to be emptied a few times each year.

7.Setting the feed adjuster # for maximum burn: With the unit burning in "AUTO", turn to "Stove Mode" and put the fan on "H". Set the Temperature Dial to #7. Allow the unit to burn for about 30 minutes and check ash on front of burn pot. Fig. 18. If the ash line is larger than 1", turn the feed adjuster from #4 to #5. Allow another

30minutes of burn time and check again. If , at #6 setting, a 1" or less ash bed is not obtainable, it is not a problem. The 1" ash bed is only a maximum burn rate and at most normal settings the ash bed will be larger.

Starting First Fire

Igniter Switch to "AUTO" (up position)

Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit.

Notice: Be sure there is no unburned fuel or other combustibles in the ash pan prior to lighting.

1.Turn Mode Selector to "OFF".

2.Fill hopper with pellets.1

3.Clean burn pot with scraper, if necessary.5

4.If starting after an empty hopper, turn Feed Adjuster to "TEST" (for one 60 second cycle).2 This will feed pellets into the auger tube and also allow you to check the motors for operation.

NOTE: The auger motor will not operate with the view door or ash pan door open.3

5.Turn Feed Adjuster to #4.4

6.Flip the Igniter Switch up into the "AUTO" position.

7.Turn the Temperature Dial to the desired temperature.

8.Turn Mode Selector to Room Temperature or Stove Temperature.

9.Fill hopper with pellets and remove ashes as required.6

KEEP THE APPLIANCE DOORS AND HOPPER LID CLOSED DURING OPERATION.

Warning

"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR "FRESHEN UP " A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE".

Warning

ONly use wood pellet fuel. Do not burn

garbage in stove.

18P61A Pellet Stove

Image 18
Contents Installation & Operating Manual Safety NoticePage Label Table of Contents Important Notes Assembly and Installation Room Sensor InstallationInstallation InstallingMobile Home Installation With outside air installed, 6 feet VentingAddition, the following must be observed Outside Air Negative Pressure, Shut-down, and Power FailurePL Vent, Must Be Used VentingVent Configurations #1 Preferred method #2 Preferred method#4 Installing into an existing chimney #5 Installing into an existingFireplace chimney #6 Installing into an existing fireplace chimney #7 Installing into an existing chimneyMinimum flue vent configuration #8 Installing through the ceilingStatus light error messages Automatic Ignition ESP ControlRoom Temperature Mode Automatic IGNITION/OPERATIONStove Temperature Mode Feed Adjuster KnobShut Down Procedure Turn Feed Adjuster to #4.4 Igniter Switch to Auto up positionTurn Mode Selector to OFF Automatic Start UPManual IGNITION/Operation Igniter Switch to Manual down position Manual Start UPFill hopper with pellets and remove ashes as required.1 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentMaintenance Glass ReplacementMinimizing Creosote Cleaning Scraping the burn potRemoving Ashes Not equipped with a fine dust filter may clog Disperse fly ash and soot into the roomSoot and Fly Ash Maintenance Burn Pot Burn Pot Cleaning and MaintenanceMaintenance Cleaning the Feeder Body Safety FeaturesFire has Gone OUT- Check for status light Trouble-ShootingCleaning Burn Pot Curing PaintFuel Specifications Fuel and Fuel StorageOperation in Stove Temp mode Operation in Room Temp modeChanges to Maintenance Schedule 30 P61A Pellet Stove Direct Vent Wall Passthrough Kit Side Heat ShieldsHopper Extension -Part#1-00-08636 Decorative Slate OptionsWiring Diagram SpecificationsLimited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService Parts Part number list on following#2 Pre Serial number 008085092 Feeder Assembly Stocked at depot#3 Post Serial number 008085803 Feeder Assembly At depotStocked Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper