Harman Stove Company P61A manual Assembly and Installation, Room Sensor Installation

Page 6

Assembly and Installation

 

Shipping Bolts

 

Note: These same holes

 

are used for securing the

Fig. 1

stove in mobile home

installation.

 

 

Rear Cover

 

Panels

Room Sensor Installation

6P61A Pellet Stove

Unpacking

The P61A is bolted (1/4 x 1" hex head bolts) to the skid to prevent movement during shipping.

To free the stove from the skid you must remove the hold-down bolts in the rear of the pedestal base.

Removing rear cover panels

The rear cover panels are secured to the stove with three bolts each. Two of the bolts need only be loosened, not removed, to remove the panels. It is recommended that the rear covers are installed after the unit is in place and the vent pipe is installed, to prevent contact with hot or moving parts.

Firebrick

Install the three firebricks vertically on the angle bracket above the burnpot.

Flame Guide

Install the cast iron flame guide on top of the burn pot. Make sure that the flame guide is fully seated on the vertical sides of the burn pot and that the back of the guide rests against the body of the stove.

INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER. Most pellet vent pipe requires a minimum of 3" of clearance to combustible materials although some can be installed at 1" clearance.

The room sensor is a small temperature sensor on the end of a 60" wire. This sensor is installed much like a standard wall thermostat. Because it is so small, it can be hidden along the trim of a doorway or even up the leg of a coffee table. There is a remote room sensor port on the rear of the unit for easy external connec- tion. Use standard 18-2 thermostat wire to extend the distance to the desired location (50' maximum). The room sensor should be installed in the location where you want to control the temperature.

In most installations locating the room sensor behind the stove near the distribution fan works well because the sensor monitors the room air being drawn into the distribution fan.

NOTE: Distances of more than 25 feet from the unit or in another room are not recommended. The room sensor is essential for the P61A's excellent ef- ficiency.

NOTE: It is recommended that the room sensor

be installed, even if only installed on the rear of the unit as a return air sensor.

Image 6
Contents Installation & Operating Manual Safety NoticePage Label Table of Contents Important Notes Assembly and Installation Room Sensor InstallationInstallation InstallingMobile Home Installation With outside air installed, 6 feet VentingAddition, the following must be observed Outside Air Negative Pressure, Shut-down, and Power FailurePL Vent, Must Be Used VentingVent Configurations #1 Preferred method #2 Preferred method#4 Installing into an existing chimney #5 Installing into an existingFireplace chimney #6 Installing into an existing fireplace chimney #7 Installing into an existing chimneyMinimum flue vent configuration #8 Installing through the ceilingStatus light error messages Automatic Ignition ESP ControlRoom Temperature Mode Automatic IGNITION/OPERATIONStove Temperature Mode Feed Adjuster KnobShut Down Procedure Turn Feed Adjuster to #4.4 Igniter Switch to Auto up positionTurn Mode Selector to OFF Automatic Start UPManual IGNITION/Operation Igniter Switch to Manual down position Manual Start UPFill hopper with pellets and remove ashes as required.1 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentMaintenance Glass ReplacementMinimizing Creosote Cleaning Scraping the burn potRemoving Ashes Not equipped with a fine dust filter may clog Disperse fly ash and soot into the roomSoot and Fly Ash Maintenance Burn Pot Burn Pot Cleaning and MaintenanceMaintenance Cleaning the Feeder Body Safety FeaturesFire has Gone OUT- Check for status light Trouble-ShootingCleaning Burn Pot Curing PaintFuel Specifications Fuel and Fuel StorageOperation in Stove Temp mode Operation in Room Temp modeChanges to Maintenance Schedule 30 P61A Pellet Stove Direct Vent Wall Passthrough Kit Side Heat ShieldsHopper Extension -Part#1-00-08636 Decorative Slate OptionsWiring Diagram SpecificationsLimited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService Parts Part number list on following#2 Pre Serial number 008085092 Feeder Assembly Stocked at depot#3 Post Serial number 008085803 Feeder Assembly At depotStocked Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper