Addendum for Burning Corn and Pellet Fuel Mixture

Harman pellet burning, free-standing stoves and inserts have been tested to ASTM E1509 for burning shelled corn in a mixture with wood pellets. The listing approves up to a 50% corn and 50% pellet mixture. Different mixtures of corn will have distinctively different burn characteristics depending upon moisture content and variety. The operator should closely monitor the stove’s operation when burning a new corn/pellet mixture or a different variety of corn, and make any necessary adjustments to feed rate. Since corn is typically higher in ash and moisture content, cleaning and ash removal will be needed more frequently.

Operation in Stove Temp mode

Set feed adjuster to # 3. Set temperature knob to #3, Turn mode selector knob onto “Stove Temp” mode. After the fire has lit, watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot grate. If it does, lower the feed adjuster setting or use a lower percentage of corn in the mixture. After the stove has burned for 10 minutes and the entire fuel bed is burning, the feed adjuster and temperature knobs may be adjusted for higher heat output if desired. Maximum feed has been reached when the fire bed is about ½ to 1 inch from the end of the burn pot. Settings will vary with different types, moisture levels and mix ratios of corn. If you are having difficulty burn- ing a 50% corn / 50% wood pellet mixture, try a lower percentage of corn.

Operation in Room Temp mode

Set feed adjuster to # 2 or # 3. Set temperature knob to desired amount. Turn mode selector knob onto “Room Temp” mode. After the fire has lit, watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the burn pot grate. After the stove has burned for 10 minutes and the entire fuel bed is burning, the feed adjuster may be set to a higher output level if desired. Maximum feed has been reached when the fire bed is about ½ to 1 inch from the end of the burn pot. It is recommended that after burning at the desired settings, turn the stove off and allow it to cool, then turn it back on in “Room Temp” mode and watch the stove restart and verify correct operation. Settings will vary with different types, moisture levels and mix ratios of corn. If you are having difficulty burning a 50% corn 50% wood pellet mixture, try a lower percentage of corn.

Changes to Maintenance Schedule

Wood pellets average around 6% moisture content or less. Corn will be 14 or 15% moisture. With more moisture in the fuel, more maintenance will be incurred. Burn pot scraping may need to be done once per day. The ash pan will fill more quickly and may need emptied weekly. Most importantly, remove the burn pot cleanout cover weekly to clean the air passage and the igniter element. Excessive buildup on the igniter may lead to shortened igniter life.

Venting Consideration: Check with your venting manufacturer regarding possible exclusions when a mixture of corn and pellets is burned.

Loosen these two wing screws for access to clean the air passage and igniter.

P61A Pellet Stove 29

Image 29
Contents Safety Notice Installation & Operating ManualPage Label Table of Contents Important Notes Room Sensor Installation Assembly and InstallationMobile Home Installation InstallationInstalling Addition, the following must be observed With outside air installed, 6 feetVenting PL Vent, Must Be Used Negative Pressure, Shut-down, and Power FailureOutside Air VentingVent Configurations #2 Preferred method #1 Preferred methodFireplace chimney #4 Installing into an existing chimney#5 Installing into an existing #7 Installing into an existing chimney #6 Installing into an existing fireplace chimney#8 Installing through the ceiling Minimum flue vent configurationAutomatic Ignition ESP Control Status light error messagesAutomatic IGNITION/OPERATION Room Temperature ModeShut Down Procedure Stove Temperature ModeFeed Adjuster Knob Turn Mode Selector to OFF Igniter Switch to Auto up positionTurn Feed Adjuster to #4.4 Automatic Start UPManual IGNITION/Operation Fill hopper with pellets and remove ashes as required.1 Igniter Switch to Manual down positionManual Start UP Low Draft Voltage Adjustment Low Draft Voltage AdjustmentMinimizing Creosote MaintenanceGlass Replacement Removing Ashes CleaningScraping the burn pot Soot and Fly Ash Not equipped with a fine dust filter may clogDisperse fly ash and soot into the room Burn Pot Cleaning and Maintenance Maintenance Burn PotSafety Features Maintenance Cleaning the Feeder BodyCleaning Burn Pot Trouble-ShootingFire has Gone OUT- Check for status light Curing PaintFuel and Fuel Storage Fuel SpecificationsChanges to Maintenance Schedule Operation in Stove Temp modeOperation in Room Temp mode 30 P61A Pellet Stove Hopper Extension -Part#1-00-08636 Side Heat ShieldsDirect Vent Wall Passthrough Kit Decorative Slate OptionsSpecifications Wiring DiagramHearth & Home Technologies Inc Limited Lifetime WarrantyThis warranty is void if Warranty ConditionsPart number list on following Service PartsStocked at depot #2 Pre Serial number 008085092 Feeder AssemblyStocked #3 Post Serial number 008085803 Feeder AssemblyAt depot Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper