Harman Stove Company P61A manual Side Heat Shields, Hopper Extension -Part#1-00-08636

Page 31

OPTIONS

Side Heat Shields

Side heat shields are available to reduce the clearance to combustible materials.

Part #1-00-08631

Hopper Extension -Part#1-00-08636

The hopper extension allows you to put more pellet fuel in the hopper which extends the burn time on one load of pellets. The hopper extension adds 70 pounds to the existing hopper capacity, allowing you to load 140 pounds of pellets at one time. The extension seals to the unit hopper with three latches. Some models will require a knockout be removed from the unit hopper prior to installing the extension.

Direct Vent Wall Passthrough Kit

You may choose to use the optional Direct Vent Wall Passthrough Kit (part #1-00-677077) which incorporates venting passthrough and outside air into one component.

Decorative Slate Options

The decorative slate tiles measure 11.938" x 5.938". The tile/slate frame is not necessary to hold the tile in place on the stove. There are 4 decorative slate choices. See dealer for samples.

The Brushed Stainless deer cutout, pictured below, is another option available. This cutout reveals the color of the stove through the cut out shapes.

frame

5.938"

tile/slate

On the rear of the stove hopper there is a

hole to fasten the hopper extension into place. On some units, this hole will need to be opened.You will notice a small uncut area on rear of the knockout. Push downward with a screwdriver or like tool until the knockout is rotated as far back to the inside of the hopper as possible. This will allow the swell latch of the hopper extension to fully expand to the bottom side of the hole for a proper seal.

11.938"

P61A Pellet Stove 31

Image 31
Contents Safety Notice Installation & Operating ManualPage Label Table of Contents Important Notes Room Sensor Installation Assembly and InstallationInstalling InstallationMobile Home Installation Venting With outside air installed, 6 feetAddition, the following must be observed Venting Negative Pressure, Shut-down, and Power FailurePL Vent, Must Be Used Outside AirVent Configurations #2 Preferred method #1 Preferred method#5 Installing into an existing #4 Installing into an existing chimneyFireplace chimney #7 Installing into an existing chimney #6 Installing into an existing fireplace chimney#8 Installing through the ceiling Minimum flue vent configurationAutomatic Ignition ESP Control Status light error messagesAutomatic IGNITION/OPERATION Room Temperature ModeFeed Adjuster Knob Stove Temperature ModeShut Down Procedure Automatic Start UP Igniter Switch to Auto up positionTurn Mode Selector to OFF Turn Feed Adjuster to #4.4Manual IGNITION/Operation Manual Start UP Igniter Switch to Manual down positionFill hopper with pellets and remove ashes as required.1 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentGlass Replacement MaintenanceMinimizing Creosote Scraping the burn pot CleaningRemoving Ashes Disperse fly ash and soot into the room Not equipped with a fine dust filter may clogSoot and Fly Ash Burn Pot Cleaning and Maintenance Maintenance Burn PotSafety Features Maintenance Cleaning the Feeder BodyCuring Paint Trouble-ShootingCleaning Burn Pot Fire has Gone OUT- Check for status lightFuel and Fuel Storage Fuel SpecificationsOperation in Room Temp mode Operation in Stove Temp modeChanges to Maintenance Schedule 30 P61A Pellet Stove Decorative Slate Options Side Heat ShieldsHopper Extension -Part#1-00-08636 Direct Vent Wall Passthrough KitSpecifications Wiring DiagramHearth & Home Technologies Inc Limited Lifetime WarrantyThis warranty is void if Warranty ConditionsPart number list on following Service PartsStocked at depot #2 Pre Serial number 008085092 Feeder AssemblyAt depot #3 Post Serial number 008085803 Feeder AssemblyStocked Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper