AUTOMATIC IGNITION/OPERATION

The P61A is a fully automatic stove that features two operating modes; Stove Temperature Mode and Room Temperature Mode. In Stove Temperature Mode, you select a burn rate and the stove will remain at the same burn rate regardless of the room temperature.

In the Room Temperature Mode the stove constantly monitors the temperature in the room and adjusts the size of the fire and the heat output of the stove so that the room is kept at a constant temperature. Room mode, in the AUTO position, has the added advantage of turning the stove off if no heat is required and turning the stove on again when the room temperature drops below your desired room temperature.

Room Temperature Mode

Most consumers use the stove in the Room Temperature Mode because it is the easiest and most efficient method of keeping the room at a given temperature. In the Room Temperature Mode, the Room Sensing Probe constantly monitors room temperature. As the weather changes outside and your home needs varying amounts of heat to be at a desired temperature, the stove will automatically increase fire size and heat output so that a constant even temperature is maintained. If the weather warms up and no heat is required, the stove will gradually shut down. When the house cools down, the stove will automatically bring the room temperature to the precise temperature you desire.

In the Room Temperature Mode you can select either Auto or Manual modes for the igniter, using the igniter toggle switch. When the toggle switch is in the Auto position, the igniter, located inside the burn pot, is ready to automatically light the fire when required. When the toggle switch set to the Manual position the stove can be lit manually with either a gel or a wax type fire starter. (see lighting instructions on page 19.) With the igniter toggle switch set in the Manual position the stove will automatically adjust heat output, but the stove will not automatically shut down if no heat is required. Instead it will go to its lowest setting and remain there. The Manual position on the igniter toggle switch lets you light the stove manually, should the igniter fail for any reason. Secondly if you are using the Harman battery back up system, the Manual setting will prevent the stove from turning off and on during a power failure, which would drain the back up battery, and possibly cause damage to the back-up or the stove.

In the Room Temperature Mode, the distribution blower speed can be increased or decreased by adjusting the Room Temp/Off/Stove Temp dial between L and H. As output of the stove increases, the speed of the blower will increase automatically to insure that more heat is transferred out into the room. The distribution blower will shut off as the room reaches the set temperature, this will prevent overheating of the room.

Room Temperature Mode

Room Temperature Mode: This setting, see above, will produce a room temperature of 70 degrees with the distribution blower at medium speed.

16P61A Pellet Stove

Image 16
Contents Installation & Operating Manual Safety NoticePage Label Table of Contents Important Notes Assembly and Installation Room Sensor InstallationInstalling InstallationMobile Home Installation Venting With outside air installed, 6 feetAddition, the following must be observed Negative Pressure, Shut-down, and Power Failure PL Vent, Must Be UsedOutside Air VentingVent Configurations #1 Preferred method #2 Preferred method#5 Installing into an existing #4 Installing into an existing chimneyFireplace chimney #6 Installing into an existing fireplace chimney #7 Installing into an existing chimneyMinimum flue vent configuration #8 Installing through the ceilingStatus light error messages Automatic Ignition ESP ControlRoom Temperature Mode Automatic IGNITION/OPERATIONFeed Adjuster Knob Stove Temperature ModeShut Down Procedure Igniter Switch to Auto up position Turn Mode Selector to OFFTurn Feed Adjuster to #4.4 Automatic Start UPManual IGNITION/Operation Manual Start UP Igniter Switch to Manual down positionFill hopper with pellets and remove ashes as required.1 Low Draft Voltage Adjustment Low Draft Voltage AdjustmentGlass Replacement MaintenanceMinimizing Creosote Scraping the burn pot CleaningRemoving Ashes Disperse fly ash and soot into the room Not equipped with a fine dust filter may clogSoot and Fly Ash Maintenance Burn Pot Burn Pot Cleaning and MaintenanceMaintenance Cleaning the Feeder Body Safety FeaturesTrouble-Shooting Cleaning Burn PotFire has Gone OUT- Check for status light Curing PaintFuel Specifications Fuel and Fuel StorageOperation in Room Temp mode Operation in Stove Temp modeChanges to Maintenance Schedule 30 P61A Pellet Stove Side Heat Shields Hopper Extension -Part#1-00-08636Direct Vent Wall Passthrough Kit Decorative Slate OptionsWiring Diagram SpecificationsLimited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService Parts Part number list on following#2 Pre Serial number 008085092 Feeder Assembly Stocked at depotAt depot #3 Post Serial number 008085803 Feeder AssemblyStocked Clean Out Cover Sets 00-06623 P61A Pellet Service & Maintenance Log P61A Pellet Stove 42 P61A Pellet Stove Page Proudly Printed On 100% Recycled Paper