1.1/2” NPT x 6” Gas Inlet Nipple

2.Gas Valve

3.Gas Valve Elbow

4.Gas Orifice Union

5.Gas Orifice

6.Union Connector Nipple

7.Main Control PC Board

8.Display PC Board

9.Pressure Switch

10.Transformer

11.ECO / Temperature Probe

12.Carborundum Ignitor

13.Flame Rectification Probe

14.Over Temperature Switch

15.Combustion Blower

16.Glass Sight Window

17.Air Inlet Adapter

18.Air Inlet Connector

19.Air Inlet Manifold

20.Exhaust Outlet Connector

21.Exhaust Elbow and Drain

22.Condensate Connector Hose

23.1/2” barb x 1/2” M Adapter

24.15/16” Hose Clamp

25.90 degree Street Elbow

26.Combination 90 degree Elbow

27.Conduit 1/32” locknut

28.Combination 90 degree Elbow

REPLACEMENT PARTS NOT SHOWN

Low Voltage Cable Assembly

Interconnect Ribbon Cable

Line Cable

Blower Cable

Gasket Burner Mounting Flange

Gasket Blower Outlet Flange

Gasket Air Inlet

Gasket Burner Mounting Flange White

14

Image 14
Contents With Installation Instructions for the Contractor USE & Care ManualSpecifications Liquefied Petroleum Models If LP GAS is Present or SuspectedN G E R Location Local Installation RegulationsTemperature and Pressure Relief Valve Expansion TankSpecial Instructions for Booster Installations Domestic Water ConnectionsElectrical Connection GAS ConnectionFor Longer Vent Lengths When Using 3 Vent Pipe Venting When Using 3 Vent PipePipe / Fittings When Using 3 Vent Pipe For Longer Vent Lengths When Using 2 Vent Pipe Special Venting Instructions Using 2 Vent PipePipe / Fittings When Using 2 Vent Pipe Cleaner / CementFriction Loss Equivalence Tables Control Description Start UP ProcedureTemperature SET Point Adjustment Procedure Never Purge from the T&P ValveMaintenance Thermostat Differential Adjustment ProcedureStatus Indicators Internal WiringCorrosive Atmospheres Failure to OperateFuel Conversions CondensateReplacement Parts not Shown Components of the AdvantagePlusIf There WAS no Ignition GAS Valve AdjustmentT E S If Ignition WAS PoorStatus Indications Under Normal Conditions Status Indications Under Normal Operating Conditions Possible Cause Remedy No Incoming Line Voltage or 24 VoltIgnitor Lockout Possible Cause ECO Switch OpenIgnition Lockout Combustion AIR Blockage Temperature Probe FaultControl Health Page Integrated Water Heater Control Very Important SET-UP Instructions Venting Samples AdvantagePlus with Storage Tank Sequence of Operations Water is heating Verify flame presence through sight window Green LED on Main Trouble Shooting Guide Most Common Advantageplus Installation Concerns