Rheem Comprehensive Manual for Water Heater Setup and Troubleshooting

Page 23

VERY IMPORTANT SET-UP INSTRUCTIONS!

USING A COMBUSTION ANALYZER, THE FOLLOWING RATINGS

WILL BE VERY HELPFUL IN SETTING UP

3" PVC

INTAKE

12" MIN.

 

8" MIN.

EXHAUST

FOR NATURAL GAS - CO2 READING SHOULD BE BETWEEN 9 1/2% & 10 1/2% O2 READING SHOULD BE BETWEEN 3 1/2% & 4 1/2 %

CO READING SHOULD BE UNDER 10 PPM

FOR PROPANE GAS - CO2 READING SHOULD BE BETWEEN 10 1/2% & 11 1/2% O2 READING SHOULD BE BETWEEN 3 1/2% & 4 1/2 %

CO READING SHOULD BE UNDER 10 PPM

23

FLOOR MOUNTED

3" ABSPIPE SUPPORT MIN. 84"

REQ'D

FIGURE 1 - SIDE VENTING

SIDE VIEW

MAINTAIN 12" MIN.

(18" MIN. FOR CANADA) CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL. MAXIMUM OF 24" ABOVE ROOF

10'

 

 

24" MIN.

 

 

 

 

- 0" MIN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAINTAIN 12" MIN.

(18" MIN. FOR CANADA) CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL. MAXIMUM OF 24" ABOVE ROOF

3" PVC

 

 

HOT

3" PVC

HOT

 

 

INTAKE

 

 

 

 

 

3" PVC

 

 

 

 

 

 

 

 

 

 

 

 

3" CONCENTRIC

 

 

 

 

 

 

VENT KIT

 

 

 

 

 

 

 

 

INTAKE

 

INTAKE

3" ABS

 

 

 

 

MIN. 84"

 

1" MIN.

 

 

 

 

 

 

 

 

 

REQ'D

 

 

 

 

 

 

EXHAUST

3" ABS

COLD

EXHAUST

COLD

EXHAUST

 

 

 

 

 

MIN. 84"

FLOOR MOUNTED

 

 

FLOOR MOUNTED

 

 

REQ'D

3" ABS

 

 

 

 

PIPE SUPPORT

 

PIPE SUPPORT

 

 

 

 

MIN. 84"

 

 

 

 

FIGURE 2 - SIDE VENTING

 

REQ'D

 

FIGURE 4

 

 

FIGURE 3 - VERTICAL ROOF VENTING

 

 

 

SIDE VIEW

FRONT VIEW

 

VERTICAL ROOF VENTING W/ CONCENTRIC VENT KIT

Image 23
Contents USE & Care Manual With Installation Instructions for the ContractorSpecifications If LP GAS is Present or Suspected Liquefied Petroleum ModelsN G E R Expansion Tank Local Installation RegulationsTemperature and Pressure Relief Valve LocationDomestic Water Connections Special Instructions for Booster InstallationsGAS Connection Electrical ConnectionFor Longer Vent Lengths When Using 3 Vent Pipe Venting When Using 3 Vent PipePipe / Fittings When Using 3 Vent Pipe Cleaner / Cement Special Venting Instructions Using 2 Vent PipePipe / Fittings When Using 2 Vent Pipe For Longer Vent Lengths When Using 2 Vent PipeFriction Loss Equivalence Tables Never Purge from the T&P Valve Start UP ProcedureTemperature SET Point Adjustment Procedure Control DescriptionInternal Wiring Thermostat Differential Adjustment ProcedureStatus Indicators MaintenanceCondensate Failure to OperateFuel Conversions Corrosive AtmospheresComponents of the AdvantagePlus Replacement Parts not ShownIf Ignition WAS Poor GAS Valve AdjustmentT E S If There WAS no IgnitionStatus Indications Under Normal Conditions Status Indications Under Normal Operating Conditions Possible Cause Remedy No Incoming Line Voltage or 24 VoltIgnitor Lockout Possible Cause ECO Switch OpenIgnition Lockout Combustion AIR Blockage Temperature Probe Fault Control Health Page Integrated Water Heater Control Very Important SET-UP Instructions Venting Samples AdvantagePlus with Storage Tank Sequence of Operations Water is heating Verify flame presence through sight window Green LED on Main Trouble Shooting Guide Most Common Advantageplus Installation Concerns