Rheem HE45-160LP, HE45-130N Control Health, Combustion AIR Blockage, Temperature Probe Fault

Page 20

LINE

K1

COMB BLOWER

K5

IGNITER ELEMENT

 

 

 

K3

K4

24

ECO/VENT

PRESSURE

GAS

GAS

VAC

SWITCH

SWITCH

VALVE

VALVE

 

 

 

RLY 1

RLY 2

 

 

 

 

GAS

 

 

 

 

VALVE

 

 

 

 

K1

 

 

CONTROL

 

K5

 

ELECTRONICS

K3

 

K4

 

 

 

 

 

CONTROL

WATER

 

 

 

HEALTH

TEMPERATURE

 

K3

K4

ECO/VENT PRESSURE

 

CONTROL HEALTH

Control Health LED Flashing

POSSIBLE CAUSE

REMEDY

This indicates that the main

Press red reset button on the

control board has failed one or

display board to reset the con-

more of its internal diagnostic

trol. If this error occurs repeat-

self-tests.

edly, replace the main control

 

board.

COMBUSTION AIR BLOCKAGE

Pressure Switch LED Flashing

LINE

K1

COMB BLOWER

K5

IGNITER ELEMENT

24

SWITCH

GAS

GAS

VAC SWITCH

VALVE

VALVE

 

 

RLY 1

RLY 2

 

 

 

GAS

 

 

 

VALVE

 

 

 

K1

 

CONTROL

 

K5

ELECTRONICS

K3

K4

 

 

 

CONTROL

WATER

 

 

HEALTH

TEMPERATURE

 

POSSIBLE CAUSE

1.Combustion air blockage.

2.Blower not operating:

a.Blower wiring

b.Blower motor

3.Defective air switch

4.One of the gas valve wires- may be disconnected dur- ing ignition sequence.

REMEDY

1. Check intake and exhaust piping for obstructions.

2a. Repair wiring.

2b. Replace blower motor.

3.Replace air switch.

4.Check wires to Gas valve. Reseat wires into harness.

5. Poly hose between the

5. Remove or correct block-

blower and air pressure

age connect hose to blow-

switch is blocked or discon-

er or air pressure switch.

nected.

 

TEMPERATURE PROBE FAULT

Water Temp LED Flashing

LINE

K1

COMB BLOWER

K5

IGNITER ELEMENT

 

 

 

K3

K4

24

ECO/VENT

PRESSURE

GAS

GAS

VAC

SWITCH

SWITCH

VALVE

VALVE

 

 

 

RLY 1

RLY 2

 

 

 

 

GAS

 

 

 

 

VALVE

 

 

 

 

K1

 

 

CONTROL

 

K5

 

ELECTRONICS

K3

 

K4

 

 

 

 

POSSIBLE CAUSE

1.Temp probe wiring open.

2.Defective probe.

3.No water in tank or tank in freezing conditions.

4.Water level in tank is too low - probe in steam.

5.Probe wiring shorted.

REMEDY

1.Repair wiring.

2.Replace probe.

3.Control is recording an “out of bounds” condition. Turn on water supply; remove tank from freezing conditions.

4.Control is recording an “out of bounds” condition. Fill tank.

5.Replace probe.

CONTROL

WATER

HEALTH

TEMPERATURE

NOTE:

If the temperature probe housing fractures and allows water into the sensor section of the probe, this may affect the temperature display on the display pnael. If the display is showing highly inconsistent temperature readings, this is an indication the temperature probe is defective due to water contamination. Replace probe.

20

Image 20
Contents With Installation Instructions for the Contractor USE & Care ManualSpecifications Liquefied Petroleum Models If LP GAS is Present or SuspectedN G E R Local Installation Regulations Temperature and Pressure Relief ValveLocation Expansion TankSpecial Instructions for Booster Installations Domestic Water ConnectionsElectrical Connection GAS ConnectionFor Longer Vent Lengths When Using 3 Vent Pipe Venting When Using 3 Vent PipePipe / Fittings When Using 3 Vent Pipe Special Venting Instructions Using 2 Vent Pipe Pipe / Fittings When Using 2 Vent PipeFor Longer Vent Lengths When Using 2 Vent Pipe Cleaner / CementFriction Loss Equivalence Tables Start UP Procedure Temperature SET Point Adjustment ProcedureControl Description Never Purge from the T&P ValveThermostat Differential Adjustment Procedure Status IndicatorsMaintenance Internal WiringFailure to Operate Fuel ConversionsCorrosive Atmospheres CondensateReplacement Parts not Shown Components of the AdvantagePlusGAS Valve Adjustment T E SIf There WAS no Ignition If Ignition WAS PoorStatus Indications Under Normal Conditions Status Indications Under Normal Operating Conditions Possible Cause Remedy No Incoming Line Voltage or 24 VoltIgnitor Lockout Possible Cause ECO Switch OpenIgnition Lockout Combustion AIR Blockage Temperature Probe FaultControl Health Page Integrated Water Heater Control Very Important SET-UP Instructions Venting Samples AdvantagePlus with Storage Tank Sequence of Operations Water is heating Verify flame presence through sight window Green LED on Main Trouble Shooting Guide Most Common Advantageplus Installation Concerns