Rheem HE45-130LP, HE45-160LP, HE45-130N, HE45-100LP, HE45-100N, HE119-199N, HE119-130N Venting Samples

Page 24

Venting Samples

HOT

3' TO 4" PVC

10' - 0" MIN.

MAINTAIN 12" MIN.

(18" MIN. FOR CANADA) CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL. MAXIMUM OF 24" ABOVE ROOF

MIN

24"

.

 

 

 

4" PVC

INTAKE

3" PVC

 

MIN. 10'

 

REQ'D

COLD

 

 

3" ABS

EXHAUST

MIN. 84"

 

REQ'D

REDUCING 4" PVC COUPLING

12"

8" MIN.

FLOOR MOUNTED

PIPE SUPPORT

HOT

 

3" PVC

 

MIN. 10'

 

REQ'D

 

 

3' TO 4" PVC

 

REDUCING

 

COUPLING

INTAKE

3" ABS

MIN. 84"

 

 

REQ'D

COLD

 

EXHAUST

 

FLOOR MOUNTED

 

PIPE SUPPORT

 

FIGURE 5 - SIDE WALL VENTING

3" 4" (SIDE VIEW)

FIGURE 6 - VERTICAL ROOF VENTING

3" 4" (FRONT VIEW)

HOT

 

 

4" PVC

 

 

 

 

3' TO 4" PVC

MAX. 125'

 

 

 

 

EQUIVALENT

 

 

 

3" PVC

REDUCING

FRESH AIR

 

INTAKE

FEET OF 4"

 

COUPLING

 

MIN. 10'

 

FOR

 

 

REQ'D

 

 

 

 

 

 

COMBUSTION

 

 

 

 

 

 

 

 

 

 

OPTIONAL V1000

 

 

 

 

 

VENT KIT

 

 

 

 

 

(SIDE VIEW)

V1000 SIDE WALL

 

 

 

 

 

VENT KIT

 

 

 

 

 

(FRONT VIEW)

COLD

 

3" ABS

 

EXHAUST

 

EXHAUST

 

 

 

 

 

MIN. 84"

 

 

 

FLOOR MOUNTED

REQ'D

3' TO 4" PVC REDUCING COUPLING

 

PIPE SUPPORT

 

 

TO UTILIZE V1000 SIDE WALL VENT TERMINAL

 

FIGURE 7 - SIDE WALL VENTING USING THE V1000 VENT KIT

3" 4" 3" (SIDE VIEW)*

*NOTE: THE ONLY TIME 4" CAN BE REDUCED BACK TO 3" IS WHEN THE V1000 VENT KIT IS UTILIZED.

24

Image 24
Contents With Installation Instructions for the Contractor USE & Care ManualSpecifications Liquefied Petroleum Models If LP GAS is Present or SuspectedN G E R Local Installation Regulations Temperature and Pressure Relief ValveLocation Expansion TankSpecial Instructions for Booster Installations Domestic Water ConnectionsElectrical Connection GAS ConnectionVenting When Using 3 Vent Pipe Pipe / Fittings When Using 3 Vent PipeFor Longer Vent Lengths When Using 3 Vent Pipe Special Venting Instructions Using 2 Vent Pipe Pipe / Fittings When Using 2 Vent PipeFor Longer Vent Lengths When Using 2 Vent Pipe Cleaner / CementFriction Loss Equivalence Tables Start UP Procedure Temperature SET Point Adjustment ProcedureControl Description Never Purge from the T&P ValveThermostat Differential Adjustment Procedure Status IndicatorsMaintenance Internal WiringFailure to Operate Fuel ConversionsCorrosive Atmospheres CondensateReplacement Parts not Shown Components of the AdvantagePlusGAS Valve Adjustment T E SIf There WAS no Ignition If Ignition WAS PoorStatus Indications Under Normal Conditions Status Indications Under Normal Operating Conditions No Incoming Line Voltage or 24 Volt Ignitor LockoutPossible Cause Remedy ECO Switch Open Ignition LockoutPossible Cause Temperature Probe Fault Control HealthCombustion AIR Blockage Page Integrated Water Heater Control Very Important SET-UP Instructions Venting Samples AdvantagePlus with Storage Tank Sequence of Operations Water is heating Verify flame presence through sight window Green LED on Main Trouble Shooting Guide Most Common Advantageplus Installation Concerns