SPECIFICATIONS

RECOVERY CAPACITIES

Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises

MODEL

INPUT (BTU/HR)

THERMAL

 

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

 

NUMBER

NAT. & LP

EFFICIENCY

UNITS

(22.2°C)

(27.8°C)

(33.3°C)

(38.9°C)

(44.4°C)

(50.0°C)

(55.6°C)

(61.1°C)

(66.7°C)

HE45-100

100,000

95%

GPH

288

230

192

165

144

128

115

105

96

 

LPH

1090

872

726

623

545

484

436

396

363

 

 

 

 

 

HE45-130

130,000

95%

GPH

374

299

249

214

187

166

150

136

125

 

HE80-130

 

HE119-130

 

 

LPH

1417

1133

944

809

708

630

567

515

472

 

HE80-160

160,000

95%

GPH

461

368

307

263

230

205

184

167

154

 

HE119-160

LPH

1744

1395

1162

996

872

775

697

634

581

 

 

 

 

HE80-199

199,000

95%

GPH

573

458

382

327

286

255

229

208

191

 

HE119-199

LPH

2169

1735

1446

1239

1084

964

867

789

723

 

 

 

 

 

 

 

 

Recovery rating is based on thermal efficiencies obtained in an AGA certified laboratory.

BOOSTER MODELS Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH)

MODEL

INPUT (BTU/HR)

THERMAL

 

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

130°F

140°F

NUMBER

NAT. & LP

EFFICIENCY

UNITS

(22.2°C)

(27.8°C)

(33.3°C)

(38.9°C)

(44.4°C)

(50.0°C)

(55.6°C)

(61.1°C)

(66.7°C)

(72.2°C)

(77.8°C)

HE45-160

160,000

95%

GPH

461

368

307

263

230

205

184

167

154

142

132

LPH

1744

1395

1162

996

872

775

697

634

581

536

498

 

 

 

HE45-199

199,000

95%

GPH

573

458

382

327

286

255

229

208

191

176

164

LPH

2169

1735

1446

1239

1084

964

867

789

723

667

620

 

 

 

All models exceed the minimum NAECA energy efficiency requirements of ASHRAE 90.1b-1989, 1992 requirements.

MAXIMUM DELIVERY

In U.S. Gallons and Liters (Includes useable storage and recovery for indicated times)

MODEL

GALLONS/

MAX.

INPUT (BTU/HR)

TEMP.

UNITS

5

10

15

20

30

45

1

2

3

MIN. TO RECOVER

 

NUMBER

LITERS

SETPOINT

NAT. & LP

RISE

MIN.

MIN.

MIN.

MIN.

MIN.

MIN.

HR.

HR.

HR.

CONTENTS

HE45-100

45

160º

100,000

100°F

GAL.

41

51

60

70

89

118

147

262

377

23

 

170

55.6°C

LTR.

156

192

228

265

337

446

555

991

1427

 

 

 

 

 

 

HE45-130

45

160º

130,000

100°F

GAL.

44

56

69

81

106

144

181

331

481

18

 

170

55.6°C

LTR.

166

214

261

308

403

544

686

1253

1819

 

 

 

 

 

 

HE80-130

80

160º

130,000

100°F

GAL.

68

81

93

106

131

168

206

355

505

32

 

303

55.6°C

LTR.

259

306

354

401

495

637

779

1345

1912

 

 

 

 

 

 

HE119-130

119

160º

130,000

100°F

GAL.

96

108

121

133

158

196

233

383

532

48

 

450

55.6°C

LTR.

363

410

457

504

599

750

882

1449

2015

 

 

 

 

 

 

HE45-160

45

180º*

160,000

100°F

GAL.

47

62

78

93

124

170

216

400

584

15

 

170

55.6°C

LTR.

177

235

294

352

468

642

817

1514

2211

 

 

 

 

 

 

HE80-160

80

160º

160,000

100°F

GAL.

71

87

102

117

148

194

240

424

609

26

 

303

55.6°C

LTR.

270

328

386

444

561

735

909

1607

2304

 

 

 

 

 

 

HE119-160

119

160º

160,000

100°F

GAL.

99

114

129

145

175

221

268

452

636

39

 

450

55.6°C

LTR.

373

432

490

548

664

838

1013

1710

2408

 

 

 

 

 

 

HE45-199

45

180º*

199,000

100°F

GAL.

51

70

89

108

146

203

261

490

719

12

 

170

55.6°C

LTR.

192

264

336

408

553

770

987

1854

2721

 

 

 

 

 

 

HE80-199

80

160º

199,000

100°F

GAL.

75

94

113

132

171

228

285

514

743

21

 

303

55.6°C

LTR.

284

357

429

501

646

863

1079

1947

2814

 

 

 

 

 

 

HE119-199

119

160º

199,000

100°F

GAL.

102

121

141

160

198

255

312

542

771

31

 

450

55.6°C

LTR.

338

460

532

604

749

966

1183

2050

2918

 

 

 

 

 

 

All models have a maximum setpoint of 160°F with the exception of the HE45-160 and HE45-199 booster models. The HE45-160 and HE45-199 have a maximum setpoint of 180°F. * NOTE: The 180º F models are shipped with all necessary components for an approved installation (see Booster Installation Kit for component list.)

DIMENSIONAL INFORMATION

All dimensions shown in English and Metric

MODEL

 

 

 

 

 

 

WATER CONNECTIONS

APPROX

 

NUMBER

UNITS

HEIGHT

 

WIDTH

DEPTH

VENT

INLET

 

OUTLET

SHIPPING WT.

 

 

 

HE45-100

inches

42

 

23 1/2

32

2

1

 

1

175 lbs.

 

HE45-130

mm

1067

 

597

813

51

25

 

25

79 kgs

 

HE45-160

inches

42

 

23 1/2

32

3

1

 

1

175 lbs.

 

HE45-199

mm

1067

 

597

813

76

25

 

25

79 kgs

 

HE80-130

inches

72

 

23 1/2

32

3*

1-1/2

 

1-1/2

235 lbs.

 

HE80-160

 

 

HE80-199

mm

1854

 

597

813

76

38

 

38

106 kgs

 

HE119-130

inches

73

 

27

36

3*

1-1/2

 

1-1/2

405 lbs.

 

HE119-160

 

 

HE119-199

mm

1854

 

686

914

76

38

 

38

184 kgs

 

 

 

 

 

 

 

 

 

 

 

 

All models require a 120V power source.

 

 

 

 

2

 

 

* 130,000 Btu models are certified to be installed with 2” venting.

 

 

 

 

 

 

0" CLEARANCE TO COMBUSTIBLES ON ALL ADVANTAGE PLUS UNITS, HOWEVER, A 24"

CONTROL PANEL SER- VICE CLEARANCE IS RECOMMENDED.

Image 2
Contents With Installation Instructions for the Contractor USE & Care ManualSpecifications Liquefied Petroleum Models If LP GAS is Present or SuspectedN G E R Location Local Installation RegulationsTemperature and Pressure Relief Valve Expansion TankSpecial Instructions for Booster Installations Domestic Water ConnectionsElectrical Connection GAS ConnectionFor Longer Vent Lengths When Using 3 Vent Pipe Venting When Using 3 Vent PipePipe / Fittings When Using 3 Vent Pipe For Longer Vent Lengths When Using 2 Vent Pipe Special Venting Instructions Using 2 Vent PipePipe / Fittings When Using 2 Vent Pipe Cleaner / CementFriction Loss Equivalence Tables Control Description Start UP ProcedureTemperature SET Point Adjustment Procedure Never Purge from the T&P ValveMaintenance Thermostat Differential Adjustment ProcedureStatus Indicators Internal WiringCorrosive Atmospheres Failure to OperateFuel Conversions CondensateReplacement Parts not Shown Components of the AdvantagePlusIf There WAS no Ignition GAS Valve AdjustmentT E S If Ignition WAS PoorStatus Indications Under Normal Conditions Status Indications Under Normal Operating Conditions Possible Cause Remedy No Incoming Line Voltage or 24 VoltIgnitor Lockout Possible Cause ECO Switch OpenIgnition Lockout Combustion AIR Blockage Temperature Probe FaultControl Health Page Integrated Water Heater Control Very Important SET-UP Instructions Venting Samples AdvantagePlus with Storage Tank Sequence of Operations Water is heating Verify flame presence through sight window Green LED on Main Trouble Shooting Guide Most Common Advantageplus Installation Concerns