Rheem HE45-130LP, HE45-160LP, HE45-130N, HE45-100LP, HE45-100N, HE119-199N, HE119-130N N G E R

Page 4

!General Safety Precautions

age, personal injury or fire: DO NOT connect this water heater to a fuel type not in accordance with unit rating plate. Propane gas for propane units. Natural gas for natural gas units. These units are not certified for any other type fuel.

!WARNING

LP appliances should not be installed below-grade (for example, in a basement) if such installation is prohibited by federal, state and/or local laws, rules, regulations, or customs.

To meet commercial water use needs, the thermostat on this water heater is adjustable up to 1600 F (Booster mod- els have a maximum setpoint of 180°F). However, water temperatures over 1250 F can cause severe burns instantly or death from scalds. This is the preferred start- ing point for setting the controls for supplying general purpose hot water.

Safety and energy conservation are factors to be consid- ered when setting the water temperature on the thermo- stat. The most energy efficient operation will result when the temperature setting is the lowest that satisfies the needs consistent with the application.

!D A N G E R

HOT

BURN

Water temperature over 125°F can cause severe burns instantly or death from scalds.

Children, disabled and elderly are at highest risk of being scalded.

See instruction manual before setting temperature at water heater.

Feel water before bathing or showering.

Temperature limiting valves are available, see manual.

Maximum water temperatures occur just after burner has shut off. To find temperature of the water being deliv- ered, turn on a hot water faucet and place a thermome- ter in the hot water stream and read the thermometer.

The following chart details the relationship of water tem- perature and time with regard to scald injury and may be used as a guide in determining the safest water temper- ature for your applications.

TIME / TEMPERATURE RELATIONSHIPS IN SCALDS

Temperature

Time to Produce Serious Burn

 

 

120˚F

More than 5 minutes

 

 

125˚F

1½ to 2 minutes

 

 

130˚F

About 30 seconds

 

 

135˚F

About 10 seconds

 

 

140˚F

Less than 5 seconds

 

 

145˚F

Less than 3 seconds

 

 

150˚F

About 1½ seconds

 

 

155˚F

About 1 second

 

 

Table courtesy of Shriners Burn Institute

The temperature of the water in the heater can be regu- lated by setting the temperature on the electronic ther- mostat. To comply with safety regulations, the thermostat was set at its lowest setting before the water heater was shipped from the factory. See the section titled SET POINT ADJUSTMENT PROCEDURE to set the electron- ic thermostat.

!DANGER

There is a Hot Water SCALD Potential if the thermo- stat is set too high.

NOTE: When this water heater is supplying general pur- pose hot water requirements for use by individuals, a thermostatically controlled mixing valve for reducing point of use water temperatures is recommended to reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further information.

4

Image 4
Contents With Installation Instructions for the Contractor USE & Care ManualSpecifications Liquefied Petroleum Models If LP GAS is Present or SuspectedN G E R Local Installation Regulations Temperature and Pressure Relief ValveLocation Expansion TankSpecial Instructions for Booster Installations Domestic Water ConnectionsElectrical Connection GAS ConnectionPipe / Fittings When Using 3 Vent Pipe Venting When Using 3 Vent PipeFor Longer Vent Lengths When Using 3 Vent Pipe Special Venting Instructions Using 2 Vent Pipe Pipe / Fittings When Using 2 Vent PipeFor Longer Vent Lengths When Using 2 Vent Pipe Cleaner / CementFriction Loss Equivalence Tables Start UP Procedure Temperature SET Point Adjustment ProcedureControl Description Never Purge from the T&P ValveThermostat Differential Adjustment Procedure Status IndicatorsMaintenance Internal WiringFailure to Operate Fuel ConversionsCorrosive Atmospheres CondensateReplacement Parts not Shown Components of the AdvantagePlusGAS Valve Adjustment T E SIf There WAS no Ignition If Ignition WAS PoorStatus Indications Under Normal Conditions Status Indications Under Normal Operating Conditions Ignitor Lockout No Incoming Line Voltage or 24 VoltPossible Cause Remedy Ignition Lockout ECO Switch OpenPossible Cause Control Health Temperature Probe FaultCombustion AIR Blockage Page Integrated Water Heater Control Very Important SET-UP Instructions Venting Samples AdvantagePlus with Storage Tank Sequence of Operations Water is heating Verify flame presence through sight window Green LED on Main Trouble Shooting Guide Most Common Advantageplus Installation Concerns