Rheem HE119-199N, HE45-160LP, HE45-130N, HE45-100LP, HE45-100N AdvantagePlus with Storage Tank

Page 25

AdvantagePlus with Storage Tank

HOT

COLD

OUT

IN

 

PUMP

Sample Reverse Manifold and Piping Diagram for the AdvantagePlus.

Check Local Codes for specific piping requirements.

GAS

COLD WATER

HOT WATER

PUMP

CHECK VALVE

CONDENSATE

DRAIN

3"

PVC

3"

PVC

GAS

 

 

 

 

 

 

 

 

COLD WATER

 

 

 

HOT WATER

3" ABS MIN 84" REQ'D

 

CONDENSATE

DRAIN

3"

PVC

3"

PVC

GAS

 

 

 

 

 

 

 

 

 

 

 

 

HOT WATER

 

3" ABS MIN 84" REQ'D

 

 

 

CONDENSATE

DRAIN

3"

PVC

3"

PVC

 

 

 

3" ABS MIN 84" REQ'D

THE INFORMATION CONTAINED IN THIS MANUAL IS FOR GUIDANCE ONLY. THE FACTORY CANNOT BE HELD

RESPONSIBLE FOR ANY PROBLEMS ENCOUNTERED WITH INSTALLATION METHODS SHOWN.

If there is a back flow preventer, or any type of a no return valve in the system, then you must install

an additional tee for a suitable potable thermal expansion tank.

25

Image 25
Contents USE & Care Manual With Installation Instructions for the ContractorSpecifications If LP GAS is Present or Suspected Liquefied Petroleum ModelsN G E R Temperature and Pressure Relief Valve Local Installation RegulationsLocation Expansion TankDomestic Water Connections Special Instructions for Booster InstallationsGAS Connection Electrical ConnectionPipe / Fittings When Using 3 Vent Pipe Venting When Using 3 Vent PipeFor Longer Vent Lengths When Using 3 Vent Pipe Pipe / Fittings When Using 2 Vent Pipe Special Venting Instructions Using 2 Vent PipeFor Longer Vent Lengths When Using 2 Vent Pipe Cleaner / CementFriction Loss Equivalence Tables Temperature SET Point Adjustment Procedure Start UP ProcedureControl Description Never Purge from the T&P ValveStatus Indicators Thermostat Differential Adjustment ProcedureMaintenance Internal WiringFuel Conversions Failure to OperateCorrosive Atmospheres CondensateComponents of the AdvantagePlus Replacement Parts not ShownT E S GAS Valve AdjustmentIf There WAS no Ignition If Ignition WAS PoorStatus Indications Under Normal Conditions Status Indications Under Normal Operating Conditions Ignitor Lockout No Incoming Line Voltage or 24 VoltPossible Cause Remedy Ignition Lockout ECO Switch OpenPossible Cause Control Health Temperature Probe FaultCombustion AIR Blockage Page Integrated Water Heater Control Very Important SET-UP Instructions Venting Samples AdvantagePlus with Storage Tank Sequence of Operations Water is heating Verify flame presence through sight window Green LED on Main Trouble Shooting Guide Most Common Advantageplus Installation Concerns