Approximate Time/Temperature Scald Chart
APPROXIMATE TIME/TEMPERATURE RELATIONSHIPS IN SCALDS
120°F (49°C) | More than 5 minutes |
125°F (52°C) | 1½ to 2 minutes |
130°F (54°C) | About 30 seconds |
135°F (57°C) | About 10 seconds |
140°F (60°C) | Less than 5 seconds |
145°F (63°C) | Less than 3 seconds |
150°F (66°C) | About 1½ seconds |
155°F (68°C) | About 1 second |
Table 2.
ALTERNATE SPACE HEATING WATER CONNECTIONS
DANGER
Toxic chemical, such as those used for boiler treatment, must not be introduced into potable water used for space heating. This water heater must not be connected to an existing heating system or component(s) previously used with a
All piping components connected to this water heater for space heating applications must be suitable for use with potable water.
WARNING
When the system requires water for space heating at temperatures higher than required for other means, an ASSE approved mixing valve must be installed to temper the water for those uses in order to reduce the scald hazard potential.
Failure to properly pipe this water heater may result in improper operation and damage to the water heater or structure.
Oxygen contamination of this water heater will cause corrosion of iron and steel components, and can lead to water heater failure.
Connect the system supply and return piping to the water heater.
Refer to Figure 10 and Figure 11 for installation examples. Maintain a minimum ½ inch (1.3 cm) clearance from hot water piping to combustible materials.
Figure 10. Alternate Space Heating Connections