SECTION X: MAINTENANCE
DANGER
DO NOT ATTEMPT TO REPAIR GAS VALVE.
DO NOT ATTEMPT TO REPAIR IGNITION MODULE.
DO NOT ATTEMPT TO REPAIR VENTURI.
DO NOT ATTEMPT TO REPAIR THERMOSTAT BOARD.
DO NOT ATTEMPT TO REPAIR TRANSFORMER.
DO NOT ATTEMPT TO REPAIR PRESSURE SWITCH.
GENERAL
KEEP APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS.
Water heater maintenance includes periodic tank flushing and cleaning, and removal of lime scale. The unit should be inspected and adjusted to maintain proper combustion. Refer to Table 5, “Suggested Maintenance Schedule”. A periodic inspection of the venting system should be made.
MAINTENANCE SCHEDULE
Following are the instructions for performing some of the recommended maintenance. Unit inspection and adjustment should be performed by a competent technician.
|
|
| Suggested Maintenance Schedule |
|
| ||
|
|
|
|
|
|
|
|
| COMPONENT |
| OPERATION |
| INTERVAL |
| REQUIRED |
|
|
|
|
|
|
|
|
| Tank |
| Sediment Removal |
| Monthly |
| Flushing |
|
|
|
|
|
|
|
|
| Anode Rods |
| Inspect |
|
| Replace as | |
|
|
|
| Required | |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Relief Valve |
| Check Operation |
|
| Proper | |
|
|
|
| Operation | |||
|
|
|
|
|
|
| |
| Blower |
| Clean Inlet Screen |
| As Required |
| Soft Brush |
|
|
|
|
|
|
|
|
| Vent & Air |
| Inspect |
| Every 3 Months |
| Joints should |
| Intake System |
|
|
| be sealed | ||
|
|
|
|
|
| ||
| Ignition System |
| Inspect |
| Annually |
| Clean of dust |
|
|
|
| and dirt | |||
|
|
|
|
|
|
| |
|
|
| Free of Shrubs & |
|
|
| Remove object |
| Vent Terminal |
|
| Monthly |
| that caused | |
|
| Debris |
|
| |||
|
|
|
|
|
| restriction | |
|
|
|
|
|
|
| |
| Combustion |
| Inspect |
| Monthly |
| Confirm |
| System |
|
|
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Condensate |
| Inspect |
| Monthly |
| Remove |
| Line |
|
|
| restriction | ||
|
|
|
|
|
|
Table 5.
FLUSHING WATER HEATER
1.Turn OFF the water heater electrical disconnect switch.
2.Open the drain valve and allow water to flow until it runs clean.
3.Close the drain valve when finished flushing.
4.Turn ON the water heater electrical disconnect switch.
41