Bradford-White Corp EF operation manual If YOU Smell GAS

Page 4

WARNING

This water heater needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air. Insufficient air supply will cause a recirculation of combustion products resulting in contamination that may be hazardous to life. This will result in carboning or sooting of the combustion chamber, burners, and flue tubes and creates a risk of asphyxiation.

This water heater requires its own separate venting system. DO NOT connect the exhaust vent into an existing vent pipe or chimney.

Water heater materials of construction, products of combustion and the fuel contain carbon monoxide, nitrogen oxides, aldehydes and/or other toxic or harmful substances which can cause death or serious injury and which are known to the state of California to cause cancer, birth defects and other reproductive harm. Always use proper safety clothing, respirators and equipment when servicing or working nearby this water heater.

Flammable items, pressurized containers or any other potential fire hazardous articles must never be placed on or adjacent to the water heater. Open containers of flammable material should not be stored or used in the same room with this water heater.

Insulation blankets are not required for this water heater. This water heater meets or exceeds the ASHRAE/IES 90.1b (latest edition) standards with respect to insulation and standby loss requirements.

Hydrogen gas can be produced in an operating water heater that has not had water drawn from the tank for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To prevent the possibility of injury under these conditions, we recommend the hot water faucet to be open for several minutes at the kitchen sink before you use any electrical appliance, which is connect to the hot water system. If hydrogen is present, there will be unusual sounds such as air escaping through the pipes as hot water begins to flow. Do not smoke or have open flame near the faucet at the time it is open.

WARNING

Liquefied petroleum gases/propane gas is heavier than air and will remain at floor level if there is a leak. Basements, crawl spaces, closets and areas below ground level will serve as pockets for accumulation of leaking gas. Before lighting, smell all around the appliance area for gas. Be sure to smell next to the floor.

IF YOU SMELL GAS:

DO NOT try to light any appliance.

DO NOT touch any electric switch; do not use any telephone in your building.

Immediately call your gas supplier from a telephone in another building. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

DO NOT OPERATE THE APPLIANCE UNTIL THE LEAKAGE IS CORRECTED!

To comply with NSF requirements this water heater is to be:

a)Sealed to the floor with sealant, in a smooth and easily cleanable way, or

b)Installed with an optional leg kit that includes legs and/or extensions that provide a minimum clearance of 6 inches (15.2 cm) beneath the water heater.

4

Image 4
Contents With Troubleshooting Guide What to do if YOU Smell GASTable of Contents Page If YOU Smell GAS Do not Operate the Appliance Until the Leakage is CorrectedSection II Specifications Dimensions InchesFeatures Section III General InformationTemperature and Pressure Relief Valve Dishwashing Machine Requirements Condensate Elbow With TrapSection IV Installation Instructions Unpacking Minimum Clearance To Combustible MaterialRecommended Minimum Clearances For Service Access Remove CrateLocation AIR RequirementsMechanical Exhausting of Room AIR Unconfined SpaceTypical Installation Illustration Chemical Vapor CorrosionTypical Two Water Heater Connection Instructions for Connections Section V Water ConnectionsScalding Approximate TIME/TEMPERATURE Relationships in Scalds Alternate Space Heating Water ConnectionsSection VI Venting Approved Venting Materials Direct Vent Installation VentingCanadian US Installations2 Installations1 Clearance above Direct Vent Terminal Clearances Page Typical Horizontal Direct Vent System Typical Vertical Direct Vent System Installation Power Vent Installation Determining required vent lengthPage Typical Horizontal Power Vent System Typical Vertical Power Vent System Installation Power Vent Maximum Vent Length Multiple INTAKE/EXHAUST Terminal Separation Distances Concentric Vent Terminal Installation Procedure Dimensional Layout of Concentric Vent KitRain Cap to Small Vent Pipe Ass’y Concentric Vent Side Wall Attachment Models Vent Pipe PreparationInitial Preparation Section VII GAS ConnectionsSelection of Materials GAS Meter Size Natural Gases only GAS Pressure RegulationWiring Diagram and Schematic Section Viii Electrical ConnectionsSection IX Operating Instructions General InstructionsTo Fill the Water Heater Sequence of OperationTemperature Adjustment Lighting InstructionsBurner Flame Check Sight Glass LocationSection X Maintenance Maintenance ScheduleGeneral Flushing Water HeaterFilling Water Heater Draining Water HeaterSediment and Lime Scale Removal Anode Inspection and Replacement To inspect or replace an anodeDrain Valve and Tank Access Panel Vent and AIR Intake SystemSection XI Troubleshooting Guide Combustion System InspectionSection XII Parts List EF Series Water HeaterCombustion Surround Assy Ignition Control Assy

EF specifications

Bradford-White Corporation, a leader in water heating technology, has long been recognized for its innovation and quality in the industry. One of its standout offerings is the EF series, a line of high-efficiency water heaters designed to meet the growing demand for energy efficiency and reliable performance in residential and commercial applications.

The Bradford-White EF (Energy Factor) series features advanced, state-of-the-art technologies that optimize energy use while providing consistent hot water availability. One of the most notable aspects of these systems is their impressive energy efficiency ratings. The EF series utilizes cutting-edge insulation materials and advanced combustion technology, helping to minimize heat loss and reduce energy consumption. Customers benefit not only from lower utility bills but also from a product that is environmentally friendly.

Key features of the EF series include a patented Hydrojet Total Performance System, which enhances efficiency by reducing sediment buildup within the tank. This system contributes to a longer lifespan and optimal performance of the water heater, ensuring users have reliable hot water even during peak demand periods. Additionally, the EF series incorporates an intelligent electronic control system that monitors and adjusts the operation of the unit, further maximizing efficiency and providing precise temperature control.

Safety is another major consideration in the design of the EF series. Bradford-White has integrated advanced safety features, including a flame arrestor and a robust pressure relief valve, which ensure that the units operate safely and adhere to the highest industry standards. This commitment to safety demonstrates Bradford-White’s focus on providing peace of mind to homeowners and business owners alike.

Ease of installation and maintenance is a significant advantage of the EF series. Its compact design allows for flexible installation options, making it suitable for a variety of spaces, including tight or hard-to-reach areas. Moreover, the EF model is designed for simplified maintenance, which helps reduce labor costs and downtime for both homeowners and professionals.

Overall, the Bradford-White EF series is an excellent choice for those seeking a reliable, efficient, and safe water heating solution. With a blend of innovative technology, energy efficiency, and user-friendly features, the EF series exemplifies Bradford-White’s commitment to quality and customer satisfaction, making it a trusted name in the water heating industry.