Bradford-White Corp EF operation manual Section II Specifications, Dimensions Inches

Page 5

SECTION II: SPECIFICATIONS

Figure 1. Dimensional Layout

 

 

 

 

 

 

 

Recovery GPH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS ( INCHES )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At Degree Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st Hr.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Del.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

E

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

Gal.

 

 

 

 

 

 

 

 

Stg.

 

 

 

 

 

 

 

 

 

 

C

 

Flr to

Flr to

 

Fl. to

 

 

 

 

H

Front

Space

 

 

 

 

 

 

 

 

At

 

 

 

 

 

 

 

 

Cap.

Therm.

 

 

 

 

 

 

 

Flr to

 

Inlet

 

T&P

 

Outlet

G

 

Fl. to

Wtr.

Heating

Gas

Relief

Shpg.

 

 

Rate

100°F

 

 

 

 

 

 

 

U.S.

 

Eff.

 

A

 

 

B

 

Vent

 

Wtr.

 

Valve

 

Wtr.

Fl. to Air

Gas

Conn.

Conn.

Conn.

Valve

Wt.

Model No.

BTU/h

Rise

 

40°F

 

100°F

140°F

Gal.

 

 

%

 

Ht.

 

 

Dia.

Outlet

Conn

Conn

Conn

 

Intake

Conn.

Dia.

Dia.

Dia.

Open.

(LBS)

 

EF60T125

125,000

187

 

364

 

145

 

104

 

60

 

 

96.0

 

57

 

28 1/4

 

5

 

 

13

 

 

40

 

 

42 1/2

52 ½

 

53 ½

1 ½

1

 

¾

 

¾

 

570

 

 

EF60T150

150,000

211

 

423

 

169

 

121

 

60

 

 

93.0

 

57

 

28 1/4

 

5

 

 

13

 

 

40

 

 

42 1/2

52 ½

 

53 ½

1 ½

1

 

¾

 

¾

 

570

 

 

EF60T199

199,999

265

 

558

 

223

 

159

 

60

 

 

92.0

 

57

 

28 1/4

 

5

 

 

13

 

 

40

 

 

42 1/2

52 ½

 

53 ½

1 ½

1

 

¾

 

¾

 

570

 

EF100T150

150,000

250

 

450

 

180

 

129

 

100

 

99.1

 

77 5/8

 

28 1/4

 

5

 

 

13

 

 

60

 

 

62 ½

 

73 1/8

74 ¾

1 ½

1

 

¾

 

¾

 

900

 

EF100T199

199,999

309

 

597

 

239

 

171

 

100

 

98.5

 

77 5/8

 

28 1/4

 

5

 

 

13

 

 

60

 

 

62 ½

 

73 1/8

74 ¾

1 ½

1

 

¾

 

¾

 

900

 

EF100T250

250,000

364

 

735

 

294

 

210

 

100

 

97.0

 

77 5/8

 

28 1/4

 

5

 

 

13

 

 

60

 

 

62 ½

 

73 1/8

74 ¾

1 ½

1

 

¾

 

1

 

900

 

EF100T300

300,000

405

 

836

 

335

 

239

 

100

 

92.0

 

77 5/8

 

28 1/4

 

5

 

 

13

 

 

60

 

 

62 ½

 

73 1/8

74 ¾

1 ½

1

 

¾

 

1

 

900

 

EF100T399

399,999

521

 

1,127

 

451

 

322

 

100

 

93.0

 

77 5/8

 

28 1/4

 

5

 

 

13

 

 

60

 

 

62 1/2

73 1/8

73 1/4

1 1/2

1

 

1

 

1

 

950

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery LPH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS ( MILLIMETERS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At Degree Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1st Hr.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

D

 

 

E

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flr to

Flr to

 

Fl. to

 

 

 

 

H

Front

Space

 

 

 

 

 

 

 

 

 

 

Del. LPH

 

 

 

 

 

 

 

Stg.

Therm.

 

 

 

Flr to

 

Inlet

T&P

Outlet

 

 

G

 

Fl. to

Wtr.

Heating

Gas

Relief

Shpg.

 

 

Model No.

 

Rate

at 56°C

 

 

 

 

 

 

 

Cap.

Eff.

 

A

 

B

Vent

 

Wtr.

Valve

 

Wtr.

Fl. to Air

 

Gas

Conn.

Conn.

Conn.

Valve

Wt.

 

 

 

KW

 

Rise

22°C

56°C

78°C

Liter

%

 

Ht.

 

Dia.

Outlet

Conn

Conn

 

Conn

Intake

Conn.

Dia.

Dia.

Dia.

Open.

(KG)

 

 

EF60T125

36.6

 

708

1378

549

 

394

 

227

 

96.0

 

1448

 

718

127

 

330

 

1016

 

1080

 

1334

 

1359

38

 

25

19

19

259

 

 

EF60T150

43.9

 

799

1601

640

 

458

 

227

 

93.0

 

1448

 

718

127

 

330

 

1016

 

1080

 

1334

 

1359

38

 

25

19

19

259

 

 

EF60T199

58.6

 

1003

2112

844

 

602

 

227

 

92.0

 

1448

 

718

127

 

330

 

1016

 

1080

 

1334

 

1359

38

 

25

19

19

259

 

 

EF100T150

43.9

 

946

1703

681

 

488

 

379

 

99.1

 

1972

 

718

127

 

330

 

1524

 

1588

 

1857

 

1899

38

 

25

19

19

408

 

 

EF100T199

58.6

 

1170

2260

905

 

647

 

379

 

98.5

 

1972

 

718

127

 

330

 

1524

 

1588

 

1857

 

1899

38

 

25

19

19

408

 

 

EF100T250

73.2

 

1378

2782

1113

 

795

 

379

 

97.0

 

1972

 

718

127

 

330

 

1524

 

1588

 

1857

 

1899

38

 

25

19

25

408

 

 

EF100T300

87.9

 

1533

3165

1268

 

905

 

379

 

92.0

 

1972

 

718

127

 

330

 

1524

 

1588

 

1857

 

1899

38

 

25

19

25

408

 

 

EF100T399

117.2

 

1,972

4,266

1,707

1,219

 

379

 

93.0

 

1972

 

718

127

 

330

 

1524

 

1588

 

1857

 

1861

38

 

25

25

25

431

 

Table 1. Specifications

5

Image 5
Contents What to do if YOU Smell GAS With Troubleshooting Guide Table of Contents Page Do not Operate the Appliance Until the Leakage is Corrected If YOU Smell GASDimensions Inches Section II SpecificationsSection III General Information FeaturesTemperature and Pressure Relief Valve Condensate Elbow With Trap Dishwashing Machine RequirementsSection IV Installation Instructions Minimum Clearance To Combustible Material UnpackingRemove Crate Recommended Minimum Clearances For Service AccessAIR Requirements LocationMechanical Exhausting of Room AIR Unconfined SpaceChemical Vapor Corrosion Typical Installation IllustrationTypical Two Water Heater Connection Scalding Section V Water ConnectionsInstructions for Connections Alternate Space Heating Water Connections Approximate TIME/TEMPERATURE Relationships in ScaldsSection VI Venting Approved Venting Materials Venting Direct Vent InstallationCanadian US Installations2 Installations1 Clearance above Direct Vent Terminal Clearances Page Typical Horizontal Direct Vent System Typical Vertical Direct Vent System Installation Determining required vent length Power Vent InstallationPage Typical Horizontal Power Vent System Typical Vertical Power Vent System Installation Power Vent Maximum Vent Length Multiple INTAKE/EXHAUST Terminal Separation Distances Dimensional Layout of Concentric Vent Kit Concentric Vent Terminal Installation ProcedureRain Cap to Small Vent Pipe Ass’y Concentric Vent Side Wall Attachment Vent Pipe Preparation ModelsSelection of Materials Section VII GAS ConnectionsInitial Preparation GAS Pressure Regulation GAS Meter Size Natural Gases onlySection Viii Electrical Connections Wiring Diagram and SchematicGeneral Instructions Section IX Operating InstructionsTo Fill the Water Heater Sequence of OperationLighting Instructions Temperature AdjustmentSight Glass Location Burner Flame CheckMaintenance Schedule Section X MaintenanceGeneral Flushing Water HeaterSediment and Lime Scale Removal Draining Water HeaterFilling Water Heater To inspect or replace an anode Anode Inspection and ReplacementVent and AIR Intake System Drain Valve and Tank Access PanelCombustion System Inspection Section XI Troubleshooting GuideEF Series Water Heater Section XII Parts ListCombustion Surround Assy Ignition Control Assy