COMMERCIAL ELECTRIC WATER HEATER
SERVICE MANUAL
TABLE OF CONTENTS
INTRODUCTION | 2 | ELECTRONIC CONTROLS | 41 |
Qualifications | 2 | CCB - Central Control Board | 42 |
Service Warning | 2 | CCB Socket & Wiring Terminal Identification | 43 |
Tools Required | 3 | CCB Enable Disable Circuit(s) Test | 45 |
INSTALLATION CONSIDERATIONS | 4 | Checking Power And Ground To The CCB | 46 |
Closed Water Systems | 4 | UIM - User Interface Module | 47 |
Thermal Expansion | 4 | ELECTRONIC CONTROL SYSTEM | 48 |
Electrical Requirements | 5 | Control System Features | 48 |
PRE SERVICE CHECKS | 6 | Control System Navigation | 48 |
Wiring Connections | 6 | The Desktop Screen | 49 |
Service Precautions | 5 | Status Icons | 50 |
WATER HEATER CONSTRUCTION | 7 | Operating States | 51 |
Surface Mount Control Models | 8 | Control System Menus | 51 |
Electronic Control Models | 9 | Temperatures Menu | 52 |
OPERATION & SERVICE | 10 | Temperature Settings | 53 |
Principles of Electricity | 10 | Heater Status Menu | 54 |
Single And Three Phase Power | 12 | Economy Mode Setup Menu | 55 |
Checking Single Phase Power | 13 | Setpoint Adjustment Value | 56 |
Checking Three Phase Power | 14 | Time Clock Settings | 57 |
Phase Conversions - Surface Mount Control Models | 15 | Daily Operating Mode Settings | 58 |
Phase Conversions - Electronic Control Models | 16 | Alarm Output Setup Menu | 59 |
Fuses | 17 | Display Settings Menu | 60 |
Surface Mount Thermostats | 18 | Heater Information Menu | 61 |
Thermostat & ECO Test | 19 | Current Fault/Alert Menu | 62 |
Heating Elements | 20 | Fault History Menu | 62 |
Heating Element Construction | 20 | Fault Occurrence Menu | 62 |
Heating Element Amperage Test | 23 | Restore Factory Defaults Menu | 63 |
Heating Element Voltage Test | 24 | Factory Default User Settings | 63 |
Heating Element Resistance & Ground Test | 25 | TROUBLESHOOTING | 64 |
Replacing Heating Elements | 26 | Common Service Problems | 64 |
Element Sensors | 27 | Surface Mount Control Models | 64 |
Element Sensor Operation | 28 | Electronic Control Models | 65 |
Contactors | 29 | Fault Conditions | 65 |
Contactor Configurations | 30 | Alert Conditions | 65 |
Contactor Inspection | 31 | Resetting The Control System | 65 |
Contactor Coil Voltage - At Contactor | 32 | Control System Unresponsive | 65 |
Contactor Coil Voltage - At CCB | 33 | UIM Display Is Blank | 65 |
Transformers | 34 | UIM Is Inoperable | 66 |
120 VAC Control Circuit Transformer Wiring | 34 | Heating Cycle Disabled | 66 |
120 VAC Control Circuit Transformer Test | 35 | Fault & Alert Messages | 67 |
24 VAC Transformer Test | 36 | No Current Detected | 67 |
Immersion Temperature Probes | 37 | Temp Probe Open | 68 |
Temperature Sensor Resistance Test | 38 | Temp Probe Short | 68 |
Temperature Sensor DC Voltage Test | 39 | Energy Cut Out (ECO) | 69 |
ECO Continuity Test | 39 |
|
|
ECO Voltage Test | 40 |
|
|