American Water Heater ITCE3-52/80/119 Introduction, Qualifications - Qualified Service Agent

Page 4
INTRODUCTION

INTRODUCTION

INTRODUCTION

This Service Manual is designed to be an aid in servicing and troubleshooting the commercial electric water heater models listed on the cover.The instructions, illustrations and procedures contained in this manual are used to verify proper operation and to diagnose and repair common service problems.

This Service Manual does not replace or supersede the Instruction Manual that came with the water heater. Always refer to the Instruction Manual that came with the water heater for complete installation instructions. If the Instruction Manual is not available copies can be obtained from the manufacturers web site or by calling the toll free phone number shown on the back cover of this Service Manual.

Review the Common Service Problems on page 64 prior to performing any service procedures.

QUALIFICATIONS - QUALIFIED SERVICE AGENT

Servicing the products referenced in this manual requires ability equivalent to that of a Qualified Agency (as defined by ANSI below) in the field involved. Installation skills such as plumbing, electrical supply are required in addition to diagnostic and electrical testing skills when performing service.

ANSI Z223.1 2006 Sec. 3.3.83: “Qualified Agency” - “Any individual, firm, corporation or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing or replacement of gas piping or (b) the connection, installation, testing, repair or servicing of appliances and equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirements of the authority having jurisdiction.”

SERVICE WARNING

If you are not qualified (as defined by ANSI above) and licensed or certified as required by the authority having jurisdiction to perform a given task do not attempt to perform any of the service, diagnostic or troubleshooting procedures described in this manual. If you do not understand the instructions given in this manual or do not feel confident in your abilities to perform a given task do not attempt to perform any procedures outlined in this manual. Call the toll free phone number listed on the back cover of this manual for technical assistance.

IMPORTANT SERVICE REMINDER

When performing any troubleshooting step outlined in this manual always consider the wiring and connectors between components. Perform a close visual inspection of all wiring and connectors to and from a given component before replacement. Ensure wires were stripped before being crimped in a wire connector. Ensure wires are crimped tightly in their connectors. Ensure connection pins in sockets and plugs are not damaged or worn. Also ensure plugs and sockets are mating properly and providing good contact.

Failure to perform this critical step or failing to perform this step thoroughly often results in needless down time, unnecessary parts replacement, and customer dissatisfaction.

Servicing should only be performed by a Qualified Service Agent

2

Image 4
Contents Service Handbook COMMERCIAL ELECTRIC WATER HEATERSMODELS STCE3-52/80/119 & ITCE3-52/80/119 Technical Support and PartsPage SERVICE MANUAL TABLE OF CONTENTSCOMMERCIAL ELECTRIC WATER HEATER QUALIFICATIONS - QUALIFIED SERVICE AGENT SERVICE WARNINGIMPORTANT SERVICE REMINDER INTRODUCTIONINSTRUCTION MANUAL TOOLS REQUIREDCLOSED WATER SYSTEMS INSTALLATION CONSIDERATIONSTHERMAL EXPANSION ELECTRICAL REQUIREMENTS Power SupplyGrounding WIRING CONNECTIONS PRE SERVICE CHECKSSERVICE PRECAUTIONS HEATING ELEMENT CONFIGURATIONS WATER HEATER CONSTRUCTIONSURFACE MOUNT CONTROL MODELS ELECTRONIC CONTROL MODELSSURFACE MOUNT CONTROL MODELS WATER HEATER CONSTRUCTIONELECTRONIC CONTROL MODELS OPERATION & SERVICE PRINCIPLES OF ELECTRICITYVoltage AmperageOhms Law Ohms Law applied to “SINGLE PHASE” 1Ø powerCalculating Amps/Ohms/Volts/Watts SINGLE AND THREE PHASE POWER L1 L2 L3Checking Single Phase 1Ø Power Checking Three Phase 3Ø Power 1 L1 and L2 terminals of the water heater’s Power Distribution Block2 L2 and L3 terminals of the water heater’s Power Distribution Block 3 L1 and L3 terminals of the water heater’s Power Distribution BlockSurface Mount Control Models Three Phase to Single Phase PHASE CONVERSIONS - SURFACE MOUNT CONTROL MODELSSurface Mount Control Models Single Phase to Three Phase Electronic Control Models Three Phase to Single Phase PHASE CONVERSIONS - ELECTRONIC CONTROL MODELSElectronic Control Models Single Phase to Three Phase Ohm Meter Method FUSESVolt Meter Method SURFACE MOUNT THERMOSTATS Thermostat & ECO Test Heating Element Construction HEATING ELEMENTSWire conductor inside tube Heating Element Configurations NUMBER OF FACTORY INSTALLEDHeating Element Ratings TOTALHeating Element Amperage ELEMENTAPPROXIMATE CURRENT - AMPS 208 VACHeating Element Amperage Test Heating Element Voltage Test Heating Element Resistance & Ground Tests Measuring ResistanceHeating Element Ground Test Replacing Heating ElementsELEMENT SENSORS Element Sensor ConstructionElement Sensor Three Current Sensors Element Sensor FunctionsElement Sensor Operation CONTACTORS Contactor Construction - How They WorkContactor Configurations Power Connection TerminalsElement Numbers/Connections Wire Colors to Elements ContactorsContactor Inspection Physically Operate MechanicalContactor Coil Voltage - At Contactor Contactor Coil Voltage - At CCB 120 VAC Control Circuit Transformer Wiring X1 120 VACTRANSFORMERS H1 H2 H3 H4 H5 N/A Primary Winding Secondary WindingPrimary Winding Voltage Test 120 VAC Control Circuit Transformer TestSecondary Winding Voltage Test 24 VAC Transformer Test IMMERSION TEMPERATURE PROBE ECO High Temperature Limit SwitchTemperature Sensor Temperature Sensor Resistance Test Temperature Sensor Resistance DataChecking Temperature Sensor Resistance WATER TEMPERATURETemperature Sensor DC Voltage Test ECO Continuity TestChecking ECO Switch Continuity DC Voltage To Temperature SensorECO Voltage Test 120 VAC To ECO120 VAC From ECO Ground ConnectionELECTRONIC CONTROLS UIM User Interface Module CCB Central Control BoardCCB - CENTRAL CONTROL BOARD CCB Socket & Wiring Terminal Identification J2 Socket - 120 VAC Power SupplyJ3 Wiring Terminals - Alarm Output Relay see page J4 Wiring Terminals - Contactor CoilsJ7 Socket - Enable / Disable Circuits 1 & 2 see pages 45 J16 Socket - Not Used J17 Wiring Terminals - Not UsedJ8 Socket - Not Used J9 Socket - Not Used J10 Socket - Not Used J13 Socket - Heating Element Sensors BankCCB Enable/Disable Circuits Test Checking for 120 VAC Checking Power and Ground To The CCBChecking for Ground Service Notes - Button Pad Ribbon Cable UIM - USER INTERFACE MODULEUIM Circuit Board Back UIM Circuit Board FrontCONTROL SYSTEM FEATURES ELECTRONIC CONTROL SYSTEMCONTROL SYSTEM NAVIGATION UIM - User Interface ModuleTHE DESKTOP SCREEN Table 1 Status Icons ICONTable 2 - Operating States Table 3 - Control System MenusSTATE MENUS†Differential Settings TEMPERATURES MENUOperating Set Point Tank TemperatureTemperature Settings Enable / Disable 1 Alarm ConditionAlarm Relay Output HEATER STATUS MENUECONOMY MODE SETUP MENU Setpoint AdjustmentDesktop Screen During Economy Mode Economy Mode Setup Menu Current TimeEconomy Mode Settings Setpoint Adjustment Value Economy Mode Settings Time Clock Settings Economy Mode All Day Economy Mode Settings Daily Operating Mode SettingsNormal Operation Between ALARM OUTPUT SETUP MENU Temp Alarm SP Used for externalAlarm SP Alarm Output SettingsDISPLAY SETTINGS MENU Display SettingsTemperature Units Backlight DelayHEATER INFORMATION MENU Elapsed TimeTotal Heating Time Bank # CyclesCURRENT FAULT / ALERT MENU FAULT HISTORY MENUFAULT OCCURRENCE MENU Main Menu - Current Fault Selected Fault History MenuRestore Factory Defaults RESTORE FACTORY DEFAULTS MENUFactory Default User Settings TROUBLESHOOTING COMMON SERVICE PROBLEMSNo Hot Water Not Enough Hot WaterFault Conditions Resetting Control SystemCONTROL SYSTEM UNRESPONSIVE Alert ConditionsControl System Unresponsive cont Heating Cycle DisabledUIM is Inoperable FAULT AND ALERT MESSAGES “No Current Detected”“Temp Probe Open” Fault & Alert Messages“Temp Probe Short” “Energy Cut Out ECO” Page Page Page Page Technical Support and Parts