American Water Heater
ITCE3-52/80/119, STCE3-52/80/119, COMMERCIAL ELECTRIC WATER HEATERS
manual
Troubleshooting
Install
Alarm Condition
Current Fault / Alert Menu
Wiring Connections
Heating Element Configurations
Economy Mode Setup Menu
Differential Settings
Restore Factory Defaults Menu
Power Supply
Page 73
NOTES
Page 72
Page 74
Image 73
Page 72
Page 74
Contents
COMMERCIAL ELECTRIC WATER HEATERS
Service Handbook
MODELS STCE3-52/80/119 & ITCE3-52/80/119
Technical Support and Parts
Page
SERVICE MANUAL
TABLE OF CONTENTS
COMMERCIAL ELECTRIC WATER HEATER
SERVICE WARNING
QUALIFICATIONS - QUALIFIED SERVICE AGENT
IMPORTANT SERVICE REMINDER
INTRODUCTION
TOOLS REQUIRED
INSTRUCTION MANUAL
CLOSED WATER SYSTEMS
INSTALLATION CONSIDERATIONS
THERMAL EXPANSION
ELECTRICAL REQUIREMENTS
Power Supply
Grounding
WIRING CONNECTIONS
PRE SERVICE CHECKS
SERVICE PRECAUTIONS
WATER HEATER CONSTRUCTION
HEATING ELEMENT CONFIGURATIONS
SURFACE MOUNT CONTROL MODELS
ELECTRONIC CONTROL MODELS
WATER HEATER CONSTRUCTION
SURFACE MOUNT CONTROL MODELS
WATER HEATER CONSTRUCTION
PRINCIPLES OF ELECTRICITY
OPERATION & SERVICE
Voltage
Amperage
Ohms Law
Ohms Law applied to “SINGLE PHASE” 1Ø power
Calculating Amps/Ohms/Volts/Watts
L1 L2 L3
SINGLE AND THREE PHASE POWER
Checking Single Phase 1Ø Power
1 L1 and L2 terminals of the water heater’s Power Distribution Block
Checking Three Phase 3Ø Power
2 L2 and L3 terminals of the water heater’s Power Distribution Block
3 L1 and L3 terminals of the water heater’s Power Distribution Block
Surface Mount Control Models Three Phase to Single Phase
PHASE CONVERSIONS - SURFACE MOUNT CONTROL MODELS
Surface Mount Control Models Single Phase to Three Phase
Electronic Control Models Three Phase to Single Phase
PHASE CONVERSIONS - ELECTRONIC CONTROL MODELS
Electronic Control Models Single Phase to Three Phase
Ohm Meter Method
FUSES
Volt Meter Method
SURFACE MOUNT THERMOSTATS
Thermostat & ECO Test
Heating Element Construction
HEATING ELEMENTS
Wire conductor inside tube
NUMBER OF FACTORY INSTALLED
Heating Element Configurations
Heating Element Ratings
TOTAL
ELEMENT
Heating Element Amperage
APPROXIMATE CURRENT - AMPS
208 VAC
Heating Element Amperage Test
Heating Element Voltage Test
Measuring Resistance
Heating Element Resistance & Ground Tests
Replacing Heating Elements
Heating Element Ground Test
Element Sensor Construction
ELEMENT SENSORS
Element Sensor
Three Current Sensors Element Sensor Functions
Element Sensor Operation
Contactor Construction - How They Work
CONTACTORS
Power Connection Terminals
Contactor Configurations
Element Numbers/Connections Wire Colors to Elements
Contactors
Physically Operate Mechanical
Contactor Inspection
Contactor Coil Voltage - At Contactor
Contactor Coil Voltage - At CCB
X1 120 VAC
120 VAC Control Circuit Transformer Wiring
TRANSFORMERS
H1 H2 H3 H4 H5 N/A Primary Winding Secondary Winding
Primary Winding Voltage Test
120 VAC Control Circuit Transformer Test
Secondary Winding Voltage Test
24 VAC Transformer Test
IMMERSION TEMPERATURE PROBE
ECO High Temperature Limit Switch
Temperature Sensor
Temperature Sensor Resistance Data
Temperature Sensor Resistance Test
Checking Temperature Sensor Resistance
WATER TEMPERATURE
ECO Continuity Test
Temperature Sensor DC Voltage Test
Checking ECO Switch Continuity
DC Voltage To Temperature Sensor
120 VAC To ECO
ECO Voltage Test
120 VAC From ECO
Ground Connection
UIM User Interface Module CCB Central Control Board
ELECTRONIC CONTROLS
CCB - CENTRAL CONTROL BOARD
J2 Socket - 120 VAC Power Supply
CCB Socket & Wiring Terminal Identification
J3 Wiring Terminals - Alarm Output Relay see page
J4 Wiring Terminals - Contactor Coils
J16 Socket - Not Used J17 Wiring Terminals - Not Used
J7 Socket - Enable / Disable Circuits 1 & 2 see pages 45
J8 Socket - Not Used J9 Socket - Not Used J10 Socket - Not Used
J13 Socket - Heating Element Sensors Bank
CCB Enable/Disable Circuits Test
Checking for 120 VAC
Checking Power and Ground To The CCB
Checking for Ground
UIM - USER INTERFACE MODULE
Service Notes - Button Pad Ribbon Cable
UIM Circuit Board Back
UIM Circuit Board Front
ELECTRONIC CONTROL SYSTEM
CONTROL SYSTEM FEATURES
CONTROL SYSTEM NAVIGATION
UIM - User Interface Module
THE DESKTOP SCREEN
ICON
Table 1 Status Icons
Table 3 - Control System Menus
Table 2 - Operating States
STATE
MENUS†
TEMPERATURES MENU
Differential Settings
Operating Set Point
Tank Temperature
Temperature Settings
Alarm Condition
Enable / Disable 1
Alarm Relay Output
HEATER STATUS MENU
Setpoint Adjustment
ECONOMY MODE SETUP MENU
Desktop Screen During Economy Mode Economy Mode Setup Menu
Current Time
Economy Mode Settings Setpoint Adjustment Value
Economy Mode Settings Time Clock Settings
Economy Mode All Day
Economy Mode Settings Daily Operating Mode Settings
Normal Operation Between
Temp Alarm SP Used for external
ALARM OUTPUT SETUP MENU
Alarm SP
Alarm Output Settings
Display Settings
DISPLAY SETTINGS MENU
Temperature Units
Backlight Delay
Elapsed Time
HEATER INFORMATION MENU
Total Heating Time
Bank # Cycles
FAULT HISTORY MENU
CURRENT FAULT / ALERT MENU
FAULT OCCURRENCE MENU
Main Menu - Current Fault Selected Fault History Menu
Restore Factory Defaults
RESTORE FACTORY DEFAULTS MENU
Factory Default User Settings
COMMON SERVICE PROBLEMS
TROUBLESHOOTING
No Hot Water
Not Enough Hot Water
Resetting Control System
Fault Conditions
CONTROL SYSTEM UNRESPONSIVE
Alert Conditions
Control System Unresponsive cont
Heating Cycle Disabled
UIM is Inoperable
“No Current Detected”
FAULT AND ALERT MESSAGES
“Temp Probe Open”
Fault & Alert Messages
“Temp Probe Short”
“Energy Cut Out ECO”
Page
Page
Page
Page
Technical Support and Parts
Related pages
Troubleshooting and Maintenance for Cisco Systems 6901
Appendix C Specifications for Cisco Systems SRW248G4P
To remove an error code 1 Unplug transformer for GE PNSF39Z01
Installing the Switch on a Wall for Allied Telesis GS900/5E
Replacement of Parts List & Packing List SR-GA721 for Panasonic SR-GA421
Selecting languages using the language code list for Pioneer DV-410V-K
Guarantee for Hotpoint SD97E
How do I remove the trim plate from the JVC KW-V20BT?
Learn more
(#)
Top
Page
Image
Contents