American Water Heater 1010 319869-000 warranty Power Vent GAS Models

Page 1

Installation and Operating Manual

HYBRID GAS WATER HEATERS

POWER VENT GAS MODELS

www.americanwaterheater.com

ANSI Z21.10.3b-2008

For Your Safety

AN ODORANT IS ADDED TO THE GAS USED

BY THIS WATER HEATER.

ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED.

 

KEEP THIS MANUAL IN THE POCKET ON HEATER FOR FUTURE REFERENCE

 

WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED.

1010

319869-000

Image 1
Contents AN Odorant is Added to the GAS Used By this Water Heater Power Vent GAS ModelsTable of Contents Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Can be triggered at any time Introduction Preparing for the InstallationPage GET to Know Your Water Heater GAS Models Replacement Parts and Deliming ProductsOperation Rough in Dimensions Installation ConsiderationsDirectly BELOW. Keep Clear of ALL Obstructions Suggested Piping Arrangement For TOP Connections Water Piping Mixing Valve UsageWater Potable Heating All models are considered Hotter Water can ScaldFacts to Consider about Location Handle Installation Earthquake Zones Page Appliances in Unconfined Spaces Combustion AIR and VentilationAppliances in Confined Spaces ALL AIR from Outdoors See Figures 12, 13 Water Piping Chemical Vapor CorrosionClosed Water Systems Thermal ExpansionHard Water TEMPERATURE-PRESSURE Relief ValveValve and Pipe Insulation if supplied GAS Piping GAS Line Purging High Altitude InstallationsFLOODING/FREEZING Filling the Water HeaterPlanning the Vent System Vent Pipe TerminationIf using 3 inch vent pipe If using 2 inch vent pipeVent Terminal INSTALLATION, Sidewall Installation of Vent SystemCondensate Masonry Side WallsInstallation Sequence Sequence of InstallationsVent terminals supplied with heater must be used Installation of Vertical Vent System Installation of Vent SYSTEM, SidewallInitial Preparation Vent Pipe PreparationSelection of Materials Step a Recommended BRUSH* Size for Primer Cement ApplicationsStep B Step F Step EStep G Connection to Vent Pipe Power Vent Filling the Water Heater Electrical ConnectionsCalibration Display Panel Operating InstructionsPage MCU Lighting Instructions For Your Safety Read Before LightingHeat Cycle Definitions State Description Temperature Regulation Temperature Probes Unique Hybrid FeaturesPage Temperature Regulation Start UP Conditions Constant Output Temperature ControlOperational Conditions Maintenance Motors Cleaning the Heat Engine Cleaning the Inlet Water FilterSnow Accumulation Flushing the Heat Exchanger Lime BUILD- UPDraining the Tank Fault Indication and Error CodesRemarks Diagnostic DisplayCode Display Example Format Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Troubleshooting There is no HOT Water or When the TAP is OpenedHOT Water Turns Cold Stays ColdLeakage Checkpoints ServiceParts Identification Item # Description AB C DEF NIP/DIP/TBO/HT Replacement Parts DescriptionKIT # Claim Procedure Service and Labor ResponsibilityConditions and Exceptions Limitation on Implied WarrantiesPage