American Water Heater 1010 319869-000 Fault Lockout Code Description Cause Remedy Type Displayed

Page 50

Fault

 

 

Lockout

 

 

Code

Description

Cause

 

Remedy

type

 

Displayed

 

 

 

 

 

 

 

 

 

E33

Water Flow Valve

The water valve did not

 

1. Check the water valve wire harness.

 

Closed.

open when attempting to

Soft

2. Change the board.

 

 

establish flow.

 

3.

Change the water valve.

E34

Proportional Valve

The closed loop control

 

Check the proportional gas valve wire

 

(PV) Response

of the proportional valve

 

harness, change the board, change

 

Too Slow.

is not functioning properly

Soft

the gas valve assembly

 

 

(control error) or the valve

 

 

 

 

 

 

 

 

 

is responding slowly (valve

 

 

 

 

 

failure).

 

 

 

E35

Repeated Flame

Low Gas Inlet Pressure.

 

1. Clean or change the water filter.

 

Loss Fault.

Low Water Flow Rate

 

2. Check the flame rod wire harness.

 

 

 

 

3.

Check line gas pressure. If it is above

 

 

 

Soft

 

5” WC check the flame rod and if it

 

 

 

 

looks dirty, clean it up using isopropyl

 

 

 

 

 

 

 

 

 

 

alcohol and a clean cloth.

 

 

 

 

4. Change the flame rod.

 

 

 

 

5. Change the board.

E36

Calibration error.

Calibration sequence

 

1.

Unplug the power cord, check the

 

 

incomplete because end

 

 

DIP switch 4 position and put it in

 

 

of “call-for-heat” during

 

 

ON position.

 

 

the calibration time, or

 

2.

Increase the set point so that a

 

 

calibration sequence not

 

 

“call-for-heat” occurs.

 

 

initiated because of lack of

Soft

3.

Drain the tank in order to lower the

 

 

“call-for-heat”, or the unit

 

 

water temperature so that a “call-

 

 

has been never calibrated

 

 

for-heat” is generated.

 

 

or Calibration is successful

 

4.

Set DIP switch 4 to OFF position.

 

 

but DIP switch 4 not set to

 

5.

Recalibrate the unit.

 

 

“normal”.

 

6.

Change the board.

E37

No Water Flow.

The heater could not start

 

1.

Check the water inlet on the heat

 

 

because the water flow was

 

 

engine.

 

 

not established. This can be

 

2.

Make a water draw during first 60

 

 

caused by an air bubble or a

 

 

seconds after putting the unit in ON

 

 

blockage in the heat engine

 

 

mode (to evacuate possible air from

 

 

water passage, a failed flow

 

 

the heat engine water passage).

 

 

sensor or a failed circulation

 

3.

Check wire harness for pump, water

 

 

pump.

Soft

 

valve and water flow sensor.

 

 

 

 

4. Check the pump 120Vac voltage

 

 

 

 

 

supply (the pump shall be energized

 

 

 

 

 

during the heating mode).

 

 

 

 

5.

Clean or change the water filter.

 

 

 

 

6. Change board.

 

 

 

 

7. Change pump.

 

 

 

 

8. Change water valve.

E99

Board Failure.

An internal diagnostic check

Soft

Change the board.

 

 

on the board has failed.

 

 

 

 

 

 

 

TABLE 5

 

 

 

Lockout types:

Continuous. Needs “Cycle the Power” or service to restart.

Soft. Will try to automatically recover and restart after 20 minutes.

Auto Reset. Will automatically restart when voltage returns to acceptable parameters.

50

www.americanwaterheater.com

Image 50
Contents Power Vent GAS Models AN Odorant is Added to the GAS Used By this Water HeaterTable of Contents Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Can be triggered at any time Preparing for the Installation IntroductionPage Operation Replacement Parts and Deliming ProductsGET to Know Your Water Heater GAS Models Installation Considerations Rough in DimensionsDirectly BELOW. Keep Clear of ALL Obstructions Water Potable Heating All models are considered Water Piping Mixing Valve UsageSuggested Piping Arrangement For TOP Connections Hotter Water can ScaldFacts to Consider about Location Handle Installation Earthquake Zones Page Appliances in Confined Spaces Combustion AIR and VentilationAppliances in Unconfined Spaces ALL AIR from Outdoors See Figures 12, 13 Closed Water Systems Chemical Vapor CorrosionWater Piping Thermal ExpansionTEMPERATURE-PRESSURE Relief Valve Hard WaterValve and Pipe Insulation if supplied GAS Piping FLOODING/FREEZING High Altitude InstallationsGAS Line Purging Filling the Water HeaterVent Pipe Termination Planning the Vent SystemIf using 2 inch vent pipe If using 3 inch vent pipeCondensate Installation of Vent SystemVent Terminal INSTALLATION, Sidewall Masonry Side WallsVent terminals supplied with heater must be used Sequence of InstallationsInstallation Sequence Installation of Vent SYSTEM, Sidewall Installation of Vertical Vent SystemSelection of Materials Vent Pipe PreparationInitial Preparation Step B Recommended BRUSH* Size for Primer Cement ApplicationsStep a Step G Connection to Vent Pipe Step EStep F Power Vent Calibration Electrical ConnectionsFilling the Water Heater Operating Instructions Display PanelPage MCU For Your Safety Read Before Lighting Lighting InstructionsHeat Cycle Definitions State Description Temperature Regulation Unique Hybrid Features Temperature ProbesPage Temperature Regulation Operational Conditions Constant Output Temperature ControlStart UP Conditions Maintenance Motors Snow Accumulation Cleaning the Inlet Water FilterCleaning the Heat Engine Flushing the Heat Exchanger Lime BUILD- UPFault Indication and Error Codes Draining the TankCode Display Example Format Diagnostic DisplayRemarks Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Troubleshooting HOT Water Turns Cold When the TAP is OpenedThere is no HOT Water or Stays ColdService Leakage CheckpointsParts Identification Item # Description AB C DEF KIT # Replacement Parts DescriptionNIP/DIP/TBO/HT Conditions and Exceptions Service and Labor ResponsibilityClaim Procedure Limitation on Implied WarrantiesPage