GTO PRO SL-2000 SERIES TECHNICAL SPECIFICATIONS
DRIVE
¥Powered by a 12 V motor with integral case hardened steel gear reduction to 90 rpm. Generates 310 in. lb. of torque at 12 V. Motor temperature range
¥Gate velocity: 1 ft/s.
POWER
¥The PRO
¥Battery charge for PRO
IMPORTANT: The transformer should not be connected directly to any battery. Transformer must be connected to the control board with a minimum of 16 gauge,
¥Solar Panel Charger can only be used on the
CONTROL
¥GTO microprocessor controlled board with temperature compensated circuits.
¥GTO
¥Limit controls are mechanical. Normally open contact.
¥Adjustable
¥Power terminal block accommodates a transformer and solar panels.
¥Operator terminal blocks accommodate safety edges and photoelectric sensors for opening and closing modes.
¥Fully compatible accessory terminal block provides connections for safety loops, wands, intercoms, card readers, phone systems, etc.
¥DIP switches simplify setup of gate operator.
¥audio entrapment alarm sounds if unit obstructs twice while opening or closing.
OPERATIONAL CAPACITY
¥The GTO/PRO
¥The GTO/PRO
1236.
Gate Capacity Chart for SL-2000 Series
(estimated number of cycles based on use with a transformer)
Opening | 20 ft. | 80 | 70 | 60 | 50 |
| |||||
| 16 ft. | 100 | 90 | 80 | 70 |
| 12 ft. | 120 | 110 | 100 | 90 |
Gate | 8 ft. | 400 lb. | 600 lb. | 800 lb. | 1000 lb. |
| 140 | 130 | 120 | 110 | |
|
|
|
|
|
|
Gate Weight
Cycles shown are for single gate, dual gates will get approximately half as many cycles.
Housing Dimensions: | Height: 18" Width: 211/2" Depth: 11" |
Shipping Weight: | Approximately 90 lb. |
Rollers should be lubricated at least four times per year.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
10