GTO SL-2000, SL-1000 installation manual Installing the Chain, To Open the Gate Manually

Page 18

INSTALLING THE CHAIN

Illustration F

Chain Bracket

Quick Release Pin

Chain

Master Link

STEP 5

After the concrete has hardened, remove the string from the quick release pins. Attach the chain to one quick release pin with a master link (see Illustration F). Run the chain through the chain sprockets (see Illustration G).

STEP 6

Pull the chain to the second chain bracket leaving approximately four inches of slack (see Illustration G). Do not pull chain tight; a tight chain will interfere with the operation of the operator. Mark the chain where it meets the second quick release pin.

Chain Bracket

Illustration G

Chain Bracket

!WARNING

• Fingers, hands, and loose clothing may be dragged into chain

sprockets.

• Fingers and hands can be injured by rotating sprockets.

• Keep hands, fingers, and loose clothing away from chain and sprockets.

!WARNING

Sprockets

Chain

Allow 1" of slack for every 10' of chain

Gate

STEP 7

Drive the pin out of the chain link using a tool such as a punch or chain break. Connect the chain to the second quick release pin using a master link (see Illustration H).

TO OPEN THE GATE MANUALLY:

1.LIFT the quick release pins UP, then PULL them OUT of the chain brackets (see illustration).

2.Lay the chain down and manually slide the gate to the desired position.

To prevent unauthorized removal of the quick release pins, install pin locks (see accessory catalog) above the quick release pins in both chain brackets.

Illustration H

Chain Bracket

Quick Release Pin

Chain

Master Link

15

Image 18
Contents Automatic Gate Operator When You Know Multiply By To Find Symbol Vehicular Gate Operator Class CategoriesTable of Contents Important Safety Instructions II. During Installation For the InstallerBefore Installation For the System DesignerIII. After Installation Entrapment Alarm UL 325 Secondary Means of Protection Against EntrapmentFor the CONSUMER/END User No ONE should Cross the Path of the Moving GateRequired Safety Precautions for Gates Point hazardSeries Moving Gate Can Cause Injury Or Death GTO PRO SL-1000 Series Technical Specifications GTO PRO SL-2000 Series Technical Specifications Parts Identification Single Gate Operator Installation Overview of Operator Installation Gate Preparation Recommended Wiring and USE of Conduit Mounting the Legs on the Slide Gate OperatorDetermining the Mounting Position and Mounting the Operator Operator side of the gate see Overview Illustration,Installing the Chain To Open the Gate ManuallyPowering the System Connecting the BatteryInstallation of the GTO Transformer Solar Zones and Gate Activity Estimated Maximum Number of Cycles Per DayStep Another see Illustration K 18VACControl Board Settings RightPotentiometers Setting the Personal Transmitter Code Mounting the Receiver FCC RegulationHowever, if your gate opens from Left to Right Adjusting the Limit SwitchesIf your gate opens from Right to Left Counter ClockwiseConnecting Safety Devices Connecting Additional Safety DevicesBLU Blue Used with GRN Green Connecting AccessoriesWHT White Used with GRN Green ORG Orange Used with GRN GreenAttaching the Housing Maintenance Is especially important for safety devicesTrouble Shooting Guide MaintenanceSystem Test Specifications Connected to these terminalsLimited Two Year Warranty Warranty and Repair ServiceInstructions for the Installation Dual Slide Gate System Dual Gate System Installation Second Gate Auxiliary Operator Parts & HardwareControl Unit Wiring the Second Operator This Step is for SL-2000/ 2200 Installation onlySetting the Control Board for Dual Gate Installations Refer to the illustrations on the nextStep Accessories Available Through Your Dealer GTO Digital Keypad F300ACCESS-ORIES Replacement Batteries Installation Check List Installation of this operator conforms to Class